Abstract

Radioembolization (RE) with 90Y-microspheres has gained widespread acceptance as a safe and effective technique for treating liver malignancies. Accurate quantification in RE is a key step in treatment planning optimization and is becoming a pressing issue in light of the Directive 2013/59/EURATOM. The aim of this study was to develop a SPECT/CT imaging protocol for quantitative imaging optimization in RE based on cutting edge imaging technology (Symbia IntevoTM system provided with the innovative xSPECT software) and a novel anthropomorphic 3D-printed phantom. In the present study, 99mTc-labeled macroaggregated albumin was used as a surrogate radiopharmaceutical for treatment planning. Gamma camera calibration factors and recovery coefficients were determined performing preliminary SPECT/CT acquisitions of a point source, a cylindrical homogeneous phantom and the NEMA/IEC phantom. Data reconstruction was performed using the built-in xSPECT package, using both the Ordered Subset Expectation–Maximization (OSEM) and the Ordered Subset Conjugated Gradient (OSCG) algorithm. Specific regions of interest (ROIs) were drawn on the MIM 6.1.7 system according to the physical volume. The quantification procedure was validated using the anthropomorphic phantom provided with a fillable liver section and spheres of different diameters (20 mm, 40 mm and a 40 mm spherical shell). The measured activity concentration in all geometries is consistent within 4%, demonstrating that the xSPECT software permit an absolute quantification in anthropomorphic geometry largely within the 10% recommended from the manufacturer. Caution is advised in the presence of spherical objects with a necrotic core, as underestimations in the order of 20% were obtained.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Medical Imaging Techniques and Applications · Advanced Radiotherapy Techniques · Hepatocellular Carcinoma Treatment and Prognosis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Laboratory of Medical Physics and Expert Systems, IRCCS Regina Elena National Cancer Institute, 00144 Rome, Italy

Medical Physics, ASL Roma 6, UOSD Fisica Sanitaria, Ospedale dei Castelli, Ariccia, 00040 Rome, Italy

Medical Physics Unit, IRCCS Istituto Romagnolo per lo Studio dei Tumori (IRST) “Dino Amadori”, 47014 Meldola, Italy

Radiology Department, IRCCS Regina Elena National Cancer Institute, 00144 Rome, Italy

Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy

Funding

Associazione Italiana per la Ricerca sul Cancro (AIRC)

References (30)

Show source-provided references
1. Global Cancer Statistics 2020: GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 Countries10.3322/caac.21660 ↗
2. International incidence and mortality trends of liver cancer: A global profile10.1038/srep45846 ↗
3. Global burden of cancer in 2008: A systematic analysis of disability-adjusted life-years in 12 world regions10.1016/S0140-6736(12)60919-2 ↗
4. Hepatocellular Carcinoma Incidence, Mortality, and Survival Trends in the United States From 1975 to 200510.1200/JCO.2008.20.7753 ↗
5. Guidelines for the diagnosis and treatment of cholangiocarcinoma: An update10.1136/gutjnl-2011-301748 ↗
6. Pathologic response and microdosimetry of 90Y microspheres in man: Review of four explanted whole livers10.1016/j.ijrobp.2004.09.004 ↗
7. Treatment of Unresectable Primary and Metastatic Liver Cancer with Yttrium-90 Microspheres (TheraSphere®): Assessment of Hepatic Arterial Embolization10.1007/s00270-005-0171-4 ↗
8. Pasciak, A., McKinney, J., and Bradley, Y. (2017). Treatment planning part II: Procedure simulation and prognostication. Handbook of Radioembolization: Physics, Biology, Nuclear Medicine, and Imaging, CRC Press/Taylor & Francis.
9. Dosimetric techniques in 90Y-microsphere therapy of liver cancer: The MIRD equations for dose calculations
10. Partition model for estimating radiation doses from yttrium-90 microspheres in treating hepatic tumours10.1007/BF01084369 ↗
11. A Comparison of Techniques for 90Y PET/CT Image-Based Dosimetry Following Radioembolization with Resin Microspheres10.3389/fonc.2014.00121 ↗
12. Phantom validation of quantitative Y-90 PET/CT-based dosimetry in liver radioembolization10.1186/s13550-017-0341-9 ↗
13. Image-Guided Personalized Predictive Dosimetry by Artery-Specific SPECT/CT Partition Modeling for Safe and Effective 90Y Radioembolization10.2967/jnumed.111.097469 ↗
14. Garin, E., Rolland, Y., Lenoir, L., Pracht, M., Mesbah, H., Porée, P., Laffont, S., Clement, B., Raoul, J., and Boucher, E. (2011). Utility of Quantitative 99mTc-MAA SPECT/CT for 90yttrium-Labelled Microsphere Treatment Planning: Calculating Vascularized Hepatic Volume and Dosimetric Approach. Int. J. Mol. Imaging, 398051.10.1155/2011/398051 ↗
15. Abdo-Man: A 3D-printed anthropomorphic phantom for validating quantitative SIRT10.1186/s40658-016-0151-6 ↗
16. Gamma camera calibration and validation for quantitative SPECT imaging with 177Lu10.1016/j.apradiso.2016.03.007 ↗
17. Gnesin, S., Leite Ferreira, P., Malterre, J., Laub, P., Prior, J., and Verdun, F. (2016). Phantom Validation of Tc-99m Absolute Quantification in a SPECT/CT Commercial Device. Comput. Math. Methods Med., 4360371.10.1155/2016/4360371 ↗
18. American Association of Physicists in Medicine (2012). The Selection, Use, Calibration, and Quality Assurance of Radionuclide Calibrators Used in Nuclear Medicine, AAPM. Report of AAPM Task Group 181.
19. Determination of gamma camera calibration factors for quantitation of therapeutic radioisotopes10.1186/s40658-018-0208-9 ↗
20. Activity concentration measurements using a conjugate gradient (Siemens xSPECT) reconstruction algorithm in SPECT/CT10.1097/MNM.0000000000000586 ↗
21. Quantitative 177Lu SPECT imaging using advanced correction algorithms in non-reference geometry10.1016/j.ejmp.2016.09.014 ↗
22. Absolute quantitation of myocardial blood flow with 201Tl and dynamic SPECT in canine: Optimisation and validation of kinetic modelling10.1007/s00259-007-0654-4 ↗
23. FDG PET/CT: EANM procedure guidelines for tumour imaging: Version 2.010.1007/s00259-014-2961-x ↗
24. Personalised versus standard dosimetry approach of selective internal radiation therapy in patients with locally advanced hepatocellular carcinoma (DOSISPHERE-01): A randomised, multicentre, open-label phase 2 trial10.1016/S2468-1253(20)30290-9 ↗
25. Personalised radioembolization improves outcomes in refractory intra-hepatic cholangiocarcinoma: A multicenter study10.1007/s00259-019-04427-z ↗
26. Towards personalised dosimetry in patients with liver malignancy treated with 90Y-SIRT using in vivo-driven radiobiological parameters10.1186/s40658-022-00479-7 ↗
27. Individualised dosimetry and safety of SIRT for intrahepatic cholangiocarcinoma10.1186/s40658-021-00406-2 ↗
28. Bombardieri, E., Seregni, E., Evangelista, L., Chiesa, C., and Chiti, A. (2018). Radioembolization of Hepatic Metastases with 90Y-Microspheres: Indications and Procedure. Clinical Applications of Nuclear Medicine Targeted Therapy, Springer.10.1007/978-3-319-63067-0 ↗
29. 3D printing of radioactive phantoms for nuclear medicine imaging10.1186/s40658-020-00292-0 ↗
30. 3D printing 18F radioactive phantoms for PET imaging10.1186/s40658-021-00383-6 ↗