Abstract
This paper has proposed and experimentally demonstrated an integrated Co2+-doped microfiber Bragg grating sensor (Co-MFBGS) that can measure the surrounding liquid refractive index (LRI) and liquid flow rate (LFR) simultaneously. The Co-MFBGS provides well-defined resonant modes of core and cladding in the reflection spectrum. By monitoring the wavelength of the cladding mode, the LRI can be measured; meanwhile, by monitoring the wavelength of the core mode caused by the heat exchange, the LFR can be measured. The LRI and LFR can be distinguished by the wavelength separation between cladding mode and core mode. The experimental results show that in aqueous glycerin solution, the maximum measurement sensitivity for LRI detection is −7.85 nm/RIU (refractive index unit), and the LFR sensitivity is −1.93 nm/(μL/s) at a flow rate of 0.21 μL/s.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Fiber Optic Sensors · Photonic and Optical Devices · Photonic Crystal and Fiber Optics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China
School of Information and Electronics, Beijing Institute of Technology, Beijing 100081, China
China Wuzhou Engineering Group, Beijing 100053, China
Funding
National Natural Science Foundation of China · China National Key R&D Program
References (29)
Show source-provided references
1. Femtosecond laser fabricated fiber Bragg grating in microfiber for refractive index sensing10.1364/OL.35.001007 ↗
2. Helical Microfiber Bragg Grating Printed by Femtosecond Laser for Refractive Index Sensing10.1109/LPT.2019.2912634 ↗
3. Fabrication and study of bent and coiled free silica nanowires: Self-coupling microloop optical interferometer10.1364/OPEX.12.003521 ↗
4. Miniature all-fiber devices based on CO(2) laser microstructuring of tapered fibers10.1364/OL.26.001137 ↗
5. Hydrofluoric acid flow etching of low-loss subwavelength-diameter biconical fiber tapers10.1364/OE.18.022593 ↗
6. Thinned Fiber Bragg Gratings as High Sensitivity Refractive Index Sensor10.1109/LPT.2004.824972 ↗
7. Highly sensitive fiber Bragg grating refractive index sensors10.1063/1.1904716 ↗
8. Bekmurzayeva, A., Dukenbayev, K., Shaimerdenova, M., Bekniyazov, I., Ayupova, T., Sypabekova, M., Molardi, C., and Tosi, D. (2018). Etched Fiber Bragg Grating Biosensor Functionalized with Aptamers for Detection of Thrombin. Sensors, 18.10.3390/s18124298 ↗
9. A label-free cardiac biomarker immunosensor based on phase-shifted microfiber Bragg grating10.1016/j.bios.2017.08.061 ↗
10. Ahsani, V., Ahmed, F., Jun, M., and Bradley, C. (2019). Tapered Fiber-Optic Mach-Zehnder Interferometer for Ultra-High Sensitivity Measurement of Refractive Index. Sensors, 19.10.3390/s19071652 ↗
11. A review on optical microfibers in fluidic applications10.1088/1361-6439/aa7a45 ↗
12. Fiber-optic refractometer based on a phase-shifted fiber Bragg grating on a side-hole fiber10.1364/OE.23.016750 ↗
13. Low-Temperature Cross-Sensitivity Refractive Index Sensor Based on Single-Mode Fiber With Periodically Modulated Taper10.1109/JSEN.2016.2517330 ↗
14. Cancer biomarker sensing using packaged plasmonic optical fiber gratings: Towards in vivo diagnosis10.1016/j.bios.2016.10.081 ↗
15. Ultrasensitive biosensor based on long period grating coated with polycarbonate-graphene oxide multilayer10.1016/j.snb.2018.08.002 ↗
16. Gold nanoparticle amplified optical microfiber evanescent wave absorption biosensor for cancer biomarker detection in serum10.1016/j.talanta.2013.11.085 ↗
17. Highly responsive NaCl detector based on inline microfiber Mach–Zehnder interferometer10.1016/j.sna.2015.11.014 ↗
18. Simultaneous measurement of refractive index and temperature using multimode microfiber-based dual Mach-Zehnder interferometer10.1364/OL.39.004049 ↗
19. Refractive index sensing based on higher order mode reflection of a microfiber Bragg grating10.1364/OE.18.026345 ↗
20. An Integrated Biological Analysis and Flow Rate Sensing for the Real-Time Detection of Carcinogen in Water Based on Co2+-Doped Optical Fibers10.1109/JSEN.2019.2948964 ↗
21. Microfluidic Flow Rate Detection with a Large Dynamic Range by Optical Manipulation10.1109/LPT.2015.2473836 ↗
22. Continuous flow micro-bioreactors for the production of biopharmaceuticals: The effect of geometry, surface texture, and flow rate10.1039/C3LC51301G ↗
23. Sensitive optofluidic flow rate sensor based on laser heating and microring resonator10.1007/s10404-015-1663-4 ↗
24. Microfluidic flowmeter based on micro “hot-wire” sandwiched Fabry-Perot interferometer10.1364/OE.23.009483 ↗
25. “Hot-wire” microfluidic flowmeter based on a microfiber coupler10.1364/OL.41.005680 ↗
26. Microfiber-Based Bragg Gratings for Sensing Applications: A Review10.3390/s120708861 ↗
27. Fiber Grating Sensors10.1109/50.618377 ↗
28. Integrated microfluidic flowmeter based on a micro-FBG inscribed in Co²?-doped optical fiber10.1364/OL.39.005877 ↗
29. Bruun, H.H. (1996). Hot-Wire Anemometry: Principles and Signal Analysis. Meas. Sci. Technol., 7.10.1088/0957-0233/7/10/024 ↗