The Auto-Regressive Model and Spectrum Information Entropy Judgment Method for High Intensity Focused Ultrasound Echo Signal
Source abstract
Abstract
For accurate evaluation of high intensity focused ultrasound (HIFU) treatment effect, it is of great importance to effectively judge whether the sampled signal is the HIFU echo signal or the noise signal. In this paper, a judgment method based on an auto-regressive (AR) model and spectrum information entropy is proposed. In total, 188 groups of data are obtained while the HIFU source is on or off through experiments, and these sampled signals are judged by this method. The judgment results of this method are compared with empirical judgments. It is found that when the segment number for the power spectrum estimated by AR model is 14 to 17, the judgment results of this method have a higher consistency with empirical judgments, and Accuracy, Sensitivity and Specificity all have good values. Moreover, after comparing and analyzing this method with the classic power spectrum estimation method, it is found that the recognition rate of the two sampled signals of this method is higher than that of the classic power spectrum estimation method. Therefore, this method can effectively judge the different types of sampled signals.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ultrasound and Hyperthermia Applications · Photoacoustic and Ultrasonic Imaging · Ultrasound Imaging and Elastography
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Physics and Electronics, Hunan Normal University, Changsha 410081, China
College of Mathematics and Physics, Hunan University of Arts and Science, Changde 415000, China
Funding
National Natural Science Foundation of China
References (22)
Show source-provided references
1. The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population10.1038/sj.bjc.6602803 ↗
2. High-intensity focused ultrasound in the treatment of solid tumours10.1038/nrc1591 ↗
3. High intensity focused ultrasound ablation: A new therapeutic option for solid tumors10.4103/0973-1482.77064 ↗
4. DNA damage response in prostate cancer cells after high-intensity focused ultrasound (HIFU) treatment
5. Microbubbles from Gas-Generating Perfluorohexane Nanoemulsions for Targeted Temperature-Sensitive Ultrasonography and Synergistic HIFU Ablation of Tumors10.1002/adma.201301655 ↗
6. Novel temperature-triggered liposome with high stability: Formulation, in vitro evaluation, and in vivo study combined with high-intensity focused ultrasound (HIFU)10.1016/j.jconrel.2013.06.003 ↗
7. EAU-ESTRO-SIOG Guidelines on Prostate Cancer. Part 1: Screening, Diagnosis, and Local Treatment with Curative Intent10.1016/j.eururo.2016.08.003 ↗
8. Response to sublethal heat treatment of prostatic tumor cells and of prostatic tumor infiltrating T-cells10.1002/pros.10314 ↗
9. Ultrasound properties of human prostate tissue during heating10.1016/S0301-5629(02)00577-X ↗
10. Ultrasonic evaluation of microwave-induced thermal lesions based on wavelet analysis of mean scatterer spacing10.1016/j.ultras.2013.03.018 ↗
11. Dependence of ultrasonic attenuation and absorption in dog soft tissues on temperature and thermal dose10.1121/1.419737 ↗
12. The changes in acoustic attenuation due to in vitro heating10.1016/S0301-5629(02)00693-2 ↗
13. Liu, B., Qian, S.Y., and Hu, W.P. (2019). Identification of Denatured Biological Tissues Based on Time-Frequency Entropy and Refined Composite Multi-Scale Weighted Permutation Entropy during HIFU Treatment. Entropy, 21.10.3390/e21070666 ↗
14. Properties of an entropy-based signal receiver with an application to ultrasonic molecular imaging10.1121/1.2722050 ↗
15. Identification of denatured and normal biological tissues based on compressed sensing and refined composite multi-scale fuzzy entropy during high intensity focused ultrasound treatment10.1088/1674-1056/abcfa7 ↗
16. Temperature Measurement Using Passive Harmonics during High Intensity Focused Ultrasound Exposures in Porcine Tissue10.12693/APhysPolA.134.524 ↗
17. Effect of selected signals of interest on ultrasonic backscattering measurement in cancellous bones10.1007/s11433-013-5113-6 ↗
18. Improvement on the linear and nonlinear auto-regressive model for predicting the NOx emission of diesel engine10.1016/j.neucom.2016.03.075 ↗
19. Efficient inference for parameters of unobservable periodic autoregressive time series10.1080/03610926.2016.1152484 ↗
20. Information Entropy As a Basic Building Block of Complexity Theory10.3390/e15093396 ↗
21. Information entropy and thermal entropy: Apples and oranges10.1007/s10825-017-1044-1 ↗
22. An information entropy-based approach to outlier detection in rough sets10.1016/j.eswa.2010.02.087 ↗