Nuclear power plants applying for license renewal are required to undertake a fatigue assessment of various components, which demands the fast calculation of transient thermal stress of the fatigue-sensitive components such as surge lines. In this study, the strategy of Green’s function database construction for the thermal stratification region was investigated, and the thermal stress calculation was shown to be more accurate by dividing the flow cases and thermal zones. Furthermore, a method to determine the fluid temperature for the thermal zones of the thermal stratification region was studied. In addition to the temperature of the hot leg fluid and the outlet fluid from the pressurizer, seven thermocouples installed on the outside wall in the thermal stratification region were used to determine the fluid temperature of thermal zones with stratification, and the calculation result of the fluid temperature was verified with the temperature Green’s functions.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Nuclear Engineering Thermal-Hydraulics · Metallurgical Processes and Thermodynamics · Structural Integrity and Reliability Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Chemical Engineering and Technology, Hebei University of Technology, Tianjin 300130, China

References (16)

Show source-provided references
1. American Society of Mechanical Engineers (2013). Environmental Effects on Components, App. W, Section III, Boiler and Pressure Vessel Code, ASME.
2. On line fatiguemeter: A large experiment in French nuclear plants10.1016/0029-5493(91)90092-V ↗
3. Framatome operating transients monitoring system used for equipment mechanical surveillance10.1016/0308-0161(89)90106-3 ↗
4. Analysis of thermal stratification in the primary circuit of a VVER-440 reactor with the CFX code10.1016/j.nucengdes.2007.02.036 ↗
5. On-line fatigue-monitoring system for nuclear power plant10.1016/0029-5493(94)90017-5 ↗
6. VEIKI (1998). Ageing Management of Nuclear Power Plant Equipment-Piping, Background Material for Regulatory Guidelines, VEIKI-VNL.
7. Fatigue relevance of stratified flows in pipes: A parametric study10.1016/j.nucengdes.2010.03.030 ↗
8. United States Nuclear Regulatory Commission (1988). Pressurizer Surge Line Thermal Stratification, Bulletin No.88-11.
9. Stress analysis of a 900 MW pressurizer surge line including stratification effects10.1016/0029-5493(95)90011-X ↗
10. A finite element program for on-line life assessment of critical plant components10.1016/j.engfailanal.2008.01.007 ↗
11. Formulation of Three-Dimensional Green’s Function and its Application to Fatigue Life Evaluation of Pressurizer10.4028/www.scientific.net/KEM.324-325.387 ↗
12. Fatigue Life Evaluation for Turbine Rotor Using Green’s Function10.1016/j.proeng.2011.04.379 ↗
13. Numerical simulation of temperature and thermal stress for nuclear piping by using computational fluid dynamics analysis and Green’s function10.1007/s12206-017-0421-9 ↗
14. Electric Power Research Institute (2004). Material Reliability Program Thermal Cycling Screening and Evaluation Model for Normally Stagnant Non-Isolable Reactor Coolant Branch Line Piping with a Generic Application Assessment, Electric Power Research Institute. MRP-132.
15. Electric Power Research Institute (1994). Thermal Stratification, Cycling, and Striping, Electric Power Research Institute. TR-103581s.
16. Green’s function method with consideration of temperature dependent material properties for fatigue monitoring of nuclear power plants10.1016/j.ijpvp.2008.09.006 ↗