Real Cyclic Load-Bearing Test of a Ceramic-Reinforced Slab
Source abstract
Abstract
Ceramic-reinforced slabs were widely used in Spain during the second half of the 20th century, especially for industrial buildings. This solution was popular due to the lack of materials at that time, as it requires almost no concrete and low ratios of reinforcement. In this study, we present and discuss the results of a real load-bearing test of a real ceramic-reinforced slab, which was loaded and reloaded cyclically for a duration of one week in order to describe any damage under a high-demand loading series. Due to the design of these slabs, the structural response is based more on shear than on bending due to the low levels of concrete and the geometry and location of re-bars. The low ratio of concrete makes these slabs ideal for short-span structures, mainly combined with steel or RC frames. The slab which was analyzed in this study covers a span of 4.88 m between two steel I-beams (IPN400), and corresponds to a building from the mid-1960s in the city of Igualada (Barcelona, Spain). A load-bearing test was carried out up to 7.50 kN/m2 by using two-story sacks full of sand. The supporting steel beams were propped up in order to avoid any interference in the results of the test; without the shoring of the steel structure, deflections would come from the combination of the ceramic slab together with the steel profiles. A process of loading and unloading was repeated for a duration of six days in order to describe the cyclic response of the slab under high levels of loading. Finally, vibration analysis of the slab was also done; the higher the load applied, the higher the fundamental frequency of the cross section, which is more comfortable in terms of serviceability.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Structural Engineering and Vibration Analysis · Civil and Structural Engineering Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Technology in Architecture, School of Architecture, Polytechnic University of Catalonia, Av Diagonal 649, 08034 Barcelona, Spain
References (13)
Show source-provided references
1. Institut de Tecnologia de la Construcció – ITEC (1992). Recomendaciones para la Terapia de Forjados Unidireccionales de Viguetas Autoportantes de Hormigón (“Recommendations for the Therapy of Unidirectional Slabs of Self-Supporting Concrete Joists”), Dirección General de Arquitectura y Urbanismo. (In Spanish).
2. The art of the technology: Construction of structures by domed ceramic with industrial systems
3. Gemma, M.S. (2011). Las últimas construcciones de fábrica de ladrillo resistente: La generación de los años cincuenta a los setenta (“The last resistant brick factory constructions: The generation from the fifties to the seventies”). Actas del Séptimo Congreso Nacional de Historia de la Construcción, Santiago de Compostela, Instituto Juan de Herrera. (In Spanish).
4. Víctor, S. (1995). Recomanacions per al reconeixement, la diagnosi i la teràpia de sostres ceramics. Recommendations for the Recognition, Diagnosis and the Therapy of Ceramics Slab, Indian Technical and Economic Cooperation.
5. Forjados cerámicos: Estudio de un colapso (“Ceramic slabs: Study of a collapse”)
6. Los forjados de cerámica armada antes y después de la primera instrucción de cálculo a rotura (“Reinforced ceramic floor slabs before and after the first breakage calculation instruction”)
7. Feldmann, M., Heinemeyer, C., Butz, C., Caetano, E., Cunha, A., Galanti, A., Goldack, O., Hechler, O., Hicks, S., and Keil, A. (2009). Design of Floor Structures for Human Induced Vibrations. JRC Scientific and Technical Reports, Publications Office of the European Union. Joint report, prepared under the JRC-ECCS cooperation agreement for the evolution of Eurocode 3 (programme of CEN TC 250).
8. Sedlacek, G., Heinemeyer, C., Butz, C., VEILING, B., Waarts, P., Van Duin, F., Hicks, S., Devine, P., and Demarco, T. (2006). Generalisation of criteria for floor vibrations for industrial, office, residential and public building and gymnastic halls. European Commission—Technical Steel Research, Office for Official Publications of the European Communities. Report EUR 21972 EN.
9. Control of vibrations induced by people walking on large span composite floor decks10.1016/j.engstruct.2011.04.021 ↗
10. Nguyen Huu, A.T. (2013). Walking Induced Floor Vibration Design and Control. [Ph.D. Thesis, Swinburne University of Technology].
11. Parametric modelling of the dynamic behaviour of a steel–concrete composite floor10.1016/j.engstruct.2014.06.010 ↗
12. Improved model for human induced vibrations of high-frequency floors10.1016/j.engstruct.2018.04.093 ↗
13. Dynamic analysis of composite beam and floors with deformable connection using plate, bar and interface elements10.1016/j.engstruct.2019.01.070 ↗