Geometrical Calibration of a 2.5D Periapical Radiography System

Che-Wei Liao, Ming-Tzu Tsai, Heng-Li Huang, Lih-Jyh Fuh, Yen-Lin Liu, Zhi-Teng Su, Jui-Ting Hsu

Applied Sciences· Volume 10· Issue 3

Abstract

The objective of this study was to develop a geometrical calibration method applicable to the 2.5D prototype Periapical Radiography System and estimate component position errors. A two-steel-ball phantom with a precisely known position was placed in front of a digital X-ray sensor for two-stage calibration. In the first stage, the following three parameters were estimated: (1) r, the distance between the focal spot and the rotation axis of the X-ray tube; (2) ψ, the included angle between the straight line formed by the X-ray tube’s focal spot and rotation axis and the straight line of the orthogonal sensor; and (3) L4, the distance between the rotation axis and the plane where the two steel balls were positioned. In the second stage, the steel balls’ positions were determined to calculate the positions of the X-ray tube on the x, y, and z axes. Computer simulation was used to verify the accuracy of the calibration method. The results indicate that for the calibration approach proposed in this study, the differences between the estimated errors and setting errors were smaller than 0.15% in the first and second stages, which is highly accurate, verifying its applicability to accurate calibration of the 2.5D Periapical Radiography System.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Radiography and Imaging · Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Graduate Institute of Biomedical Sciences, China Medical University, Taichung 404, Taiwan

Department of Biomedical Engineering, Hungkuang University, Taichung 433, Taiwan

School of Dentistry, College of Dentistry, China Medical University, Taichung 404, Taiwan

Department of Bioinformatics and Medical Engineering, Asia University, Taichung 413, Taiwan

Department of Dentistry, China Medical University and Hospital, Taichung 404, Taiwan

Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung 404, Taiwan

Funding

China Medical University, Taiwan

References (36)

Show source-provided references
1. Periapical radiographic techniques during endodontic diagnosis and treatment10.1046/j.1365-2591.1997.00078.x ↗
2. Modern dental imaging: A review of the current technology and clinical applications in dental practice10.1007/s00330-010-1836-1 ↗
3. Development and evaluation of reconstruction methods for an in-house designed cone-beam micro-CT imaging system10.4015/S1016237206000415 ↗
4. Dental cone beam CT: A review10.1016/j.ejmp.2015.09.004 ↗
5. Technical aspects of dental CBCT: State of the art10.1259/dmfr.20140224 ↗
6. Quality assurance in digital dental imaging: A systematic review10.3109/00016357.2013.840736 ↗
7. New dimensions in endodontic imaging: Part 1. Conventional and alternative radiographic systems10.1111/j.1365-2591.2008.01530.x ↗
8. Prototype of a 2.5 D periapical radiography system using an intraoral computed tomosynthesis approach10.4015/S1016237218500047 ↗
9. Stationary intraoral digital tomosynthesis using a carbon nanotube X-ray source array10.1259/dmfr.20150098 ↗
10. Inscoe, C.R., Wu, G., Soulioti, D.E., Platin, E., Mol, A., Gaalaas, L.R., Anderson, M.R., Tucker, A.W., Boyce, S., and Shan, J. (2017, January 13–16). Stationary intraoral tomosynthesis for dental imaging. Proceedings of the Medical Imaging 2017: Physics of Medical Imaging, Orlando, FL, USA.10.1117/12.2254632 ↗
11. Characterization and preliminary imaging evaluation of a clinical prototype stationary intraoral tomosynthesis system10.1002/mp.13214 ↗
12. Liao, C.-W., Huang, K.-J., Chen, J.-C., Kuo, C.-W., Wu, Y.-Y., and Hsu, J.-T. (2019). A Prototype Intraoral Periapical Sensor with High Frame Rates for a 2.5 D Periapical Radiography System. Appl. Bionics Biomech., 2019.10.1155/2019/7987496 ↗
13. Xiang, Q., Wang, J., and Cai, Y. (2016, January 20–22). A geometric calibration method for cone beam CT system. Proceedings of the Eighth International Conference on Digital Image Processing (ICDIP 2016), Chengu, China.10.1117/12.2244579 ↗
14. Geometric parameters estimation and calibration in cone-beam micro-CT10.3390/s150922811 ↗
15. Geometric calibration for a dual tube/detector micro-CT system10.1118/1.2900000 ↗
16. Geometric misalignment and calibration in cone-beam tomography: Geometric misalignment and calibration in cone-beam tomography10.1118/1.1803792 ↗
17. Geometric estimation method for x-ray digital intraoral tomosynthesis10.1117/1.OE.55.6.063105 ↗
18. Richard, L., and Webber, W.-S. (1994). Self-calibrated tomosynthetic, radiographic-imaging system, method, and device. (No 5,359,637), U.S. Patent.
19. Yang, Y., Li, L., Chen, Z., and Chang, M. (2014, January 8–15). Geometrical calibration method for x-ray intra-oral digital tomosynthesis. Proceedings of the 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Seattle, WA, USA.
20. X-ray digital intra-oral tomosynthesis for quasi-three-dimensional imaging: System, reconstruction algorithm, and experiments10.1117/1.OE.52.1.013201 ↗
21. Geometry calibration between X-ray source and detector for tomosynthesis with a portable X-ray system10.1007/s11548-017-1557-x ↗
22. A phantom-based calibration method for digital x-ray tomosynthesis
23. Chtcheprov, P., Hartman, A., Shan, J., Lee, Y.Z., Zhou, O., and Lu, J. (March, January 27). Optical geometry calibration method for free-form digital tomosynthesis. Proceedings of the Medical Imaging 2016: Physics of Medical Imaging, San Diego, CA, USA.10.1117/12.2216851 ↗
24. AAE and AAOMR joint position statement: Use of cone beam computed tomography in endodontics 2015 update10.1016/j.oooo.2015.07.033 ↗
25. Clinical validity of the interactive and low-dose three-dimensional dento-alveolar imaging system, Tuned-Aperture Computed Tomography10.2209/tdcpublication.44.159 ↗
26. Computerized tomosynthesis of dental tissues10.1016/0030-4220(83)90289-X ↗
27. Tomosynthesis: A three-dimensional radiographic imaging technique10.1109/TBME.1972.324154 ↗
28. Digital tomosynthesis-experiences with a new imaging device for the dental field10.1007/s00784-003-0195-6 ↗
29. Tuned aperture computed tomography (TACT®) for cross-sectional implant site assessment in the posterior mandible10.1016/S1059-941X(03)00004-4 ↗
30. Diagnostic ability of extraoral tuned aperture computed tomography (TACT) for impacted third molars10.1016/j.tripleo.2004.12.001 ↗
31. Array geometry for assessment of mandibular implant position using tuned aperture computed tomography (TACT™)10.1259/dmfr/18567887 ↗
32. Accuracy of extraoral tuned aperture computed tomography (TACT) for proximal caries detection10.1016/j.tripleo.2005.04.005 ↗
33. A geometric calibration method for cone beam CT systems10.1118/1.2198187 ↗
34. A calibration method for misaligned scanner geometry in cone-beam computed tomography10.1016/j.ndteint.2006.03.002 ↗
35. Wang, X., Mainprize, J.G., Kempston, M.P., Mawdsley, G.E., and Yaffe, M.J. (2007, January 18–22). Digital breast tomosynthesis geometry calibration. Proceedings of the Medical Imaging 2007: Physics of Medical Imaging, San Diego, CA, USA.10.1117/12.698714 ↗
36. Claus, B.E.H., Opsahl-Ong, B., and Yavuz, M. (2005). Method, apparatus, and medium for calibration of tomosynthesis system geometry using fiducial markers with non-determined position. (No. 6,888,924), U.S. Patent.