journal article·2019-07-31Open access

Ion Selective Electrodes for Flue Gas Desulfurization Wastewater Monitoring: Effects of Ionic Strength on Selective Ions

Kyle McGaughy, Jay P. Wilhelm, M. Toufiq Reza

Applied Sciences· Volume 9· Issue 15

Abstract

Ion selective electrodes (ISE) were evaluated for use in a flue gas desulfurization (FGD) wastewater monitoring system. Calcium, chloride, nitrate, and nitrite ISE’s were calibrated in a broad range of concentrations that were designed to model an actual FGD wastewater sample that was obtained from an industrial partner. Ideal Nernst, Modified Nernst, and a multiparameter regression analysis was performed for each electrode and evaluated on general fit and sensitivity at anticipated operating conditions. The Ideal Nernst equation, even with correction for ionic strength, was not able to properly model actual electrode performance. The multiparameter regression was able to model the electrode performance with relative errors of 10–25% when ionic strengths were below 0.1 M. Through the evaluation of real-time sensor usage at real conditions, a methodology of washing and sampling rate is suggested to minimize error in the readings.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Gas Sensing Nanomaterials and Sensors · Acoustic Wave Resonator Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute for Sustainable Energy and the Environment, 350 West State Street, Athens, OH 45701, USA

Department of Mechanical Engineering, 1 Ohio University, Athens, OH 45701, USA

Funding

Ohio Coal Development Office

References (12)

Show source-provided references
1. US EPA, O. (2017, December 28). Steam Electric Power Generating Effluent Guidelines—2015 Final Rule, Available online: https://www.epa.gov/eg/steam-electric-power-generating-effluent-guidelines-2015-final-rule.
2. Ca2+-Selective Electrode: A Simple Method to Measure the Phytase-Aided Release of Bound Calcium in Soymilk10.1016/j.jfca.2014.11.005 ↗
3. A calcium ion-selective electrode array for monitoring the activity of HepG2/C3As in a microchannel10.1016/j.snb.2012.07.098 ↗
4. A palladium imprinted polymer for highly selective and sensitive electrochemical determination of ultra-trace of palladium ions10.1016/j.electacta.2014.10.096 ↗
5. Synthesis, characterization and application of novel lead imprinted polymer nanoparticles as a high selective electrochemical sensor for ultra-trace determination of lead ions in complex matrixes10.1016/j.electacta.2014.05.095 ↗
6. Indirect determination of zeta potential at high ionic strength: Specific application to semipermeable polymeric membranes10.1016/j.memsci.2014.12.047 ↗
7. A tutorial on the application of ion-selective electrode potentiometry: An analytical method with unique qualities, unexplored opportunities and potential pitfalls; Tutorial10.1016/j.aca.2012.11.022 ↗
8. Ion-selective electrodes—Analogies and conclusions10.1002/elan.1140080409 ↗
9. Prentice, G. (1991). Electrochemical Engineering Principles, Prentice Hall.
10. Influence of key parameters on the lower detection limit and response function of solvent polymeric membrane ion-selective electrodes10.1016/S0022-0728(00)00488-5 ↗
11. Integrated multi-ISE arrays with improved sensitivity, accuracy and precision10.1038/srep44771 ↗
12. Solubility of Gypsum in Aqueous NaCl + K2SO4 Solution Using Calcium Ion Selective Electrode-Investigation of Ionic Interactions10.1016/j.fluid.2015.10.011 ↗