journal article·2018-10-18Open access

Impact of Combination Therapy with Ezetimibe/Simvastatin Treatment on the Neointimal Response to Biodegradable Polymer Biolimus-Eluting Stent Implantation in Patients with Acute Myocardial Infarction: Serial Assessment with Optical Coherence Tomography

Yongcheol Kim, Young Joon Hong, Sang Wook Kim, Min Chul Kim, Doo Sun Sim, Ju Han Kim, Youngkeun Ahn, Myung Ho Jeong

Applied Sciences· Volume 8· Issue 10

Abstract

The aim of this study was to compare the neointimal response at 12-month follow-up between ezetimibe/simvastatin (Vytorin, manufactured by Merck) 10/10 mg and Vytorin 10/40 mg after biodegradable polymer Biolimus-eluting stent (BP-BES) implantation in patients with acute myocardial infarction (AMI). A total of 20 patients requiring revascularization were randomly assigned to receive either Vytorin 10/10 mg (n = 9) or Vytorin 10/40 mg (n = 11). Baseline optical coherence tomography (OCT) was performed after stent implantation, and follow-up OCT was scheduled at 12 months. We performed follow-up OCT in 18 patients (Vytorin 10/10 mg (n = 9) or Vytorin 10/40 mg (n = 9)). A total of 842 frames and 8552 struts were analyzed at initial and follow-up OCT. At follow-up, the percentage of uncovered struts was not significantly different between both groups (6.61 ± 10.29% vs. 7.57 ± 6.45%, p = 0.815). The percentage of malapposed struts was also similar between both groups (0.69 ± 1.58% vs. 1.55 ± 2.72%, respectively, p = 0.422). Mean percent neointimal hyperplasia area was not significantly different between both groups (6.53 ± 3.26% vs. 6.37 ± 8.96%, p = 0.961). This OCT study showed that both high- and moderate-intensity dosing of Vytorin was associated with relatively lower percentages of uncovered struts and malapposed struts after Biolimus A9-eluting stent implantation in patients with AMI.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Coronary Interventions and Diagnostics · Cardiac Imaging and Diagnostics · Integrated Circuits and Semiconductor Failure Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Cardiology, Chonnam National University Hospital, Gwangju 61469, Korea

Department of Cardiology, Chung-Ang University Hospital, Seoul 06973, Korea

References (28)

Show source-provided references
1. Maintenance of long-term clinical benefit with sirolimus-eluting coronary stents: Three-year results of the RAVEL trial10.1161/01.CIR.0000156334.24955.B2 ↗
2. Sirolimus-eluting stents remain superior to bare-metal stents at two years: Medium-term results from the Rapamycin-Eluting Stent Evaluated at Rotterdam Cardiology Hospital (RESEARCH) registry10.1016/j.jacc.2005.05.102 ↗
3. Late angiographic stent thrombosis after sirolimus-eluting stent implantation10.1253/circj.71.226 ↗
4. Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents10.1056/NEJMoa067484 ↗
5. Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents10.1161/CIRCULATIONAHA.104.508937 ↗
6. Pathological correlates of late drug-eluting stent thrombosis: Strut coverage as a marker of endothelialization10.1161/CIRCULATIONAHA.107.693739 ↗
7. Mechanisms of Very Late Drug-Eluting Stent Thrombosis Assessed by Optical Coherence Tomography10.1161/CIRCULATIONAHA.115.019071 ↗
8. Optical Coherence Tomography Findings in Patients With Coronary Stent Thrombosis: A Report of the PRESTIGE Consortium (Prevention of Late Stent Thrombosis by an Interdisciplinary Global European Effort)10.1161/CIRCULATIONAHA.117.026788 ↗
9. Ezetimibe Added to Statin Therapy after Acute Coronary Syndromes10.1056/NEJMoa1410489 ↗
10. 2016 ESC/EAS Guidelines for the Management of Dyslipidaemias10.1093/eurheartj/ehw272 ↗
11. 2017 Focused Update of the 2016 ACC Expert Consensus Decision Pathway on the Role of Non-Statin Therapies for LDL-Cholesterol Lowering in the Management of Atherosclerotic Cardiovascular Disease Risk: A Report of the American College of Cardiology Task Force on Expert Consensus Decision Pathways
12. BioMatrix Biolimus A9-eluting coronary stent: A next-generation drug-eluting stent for coronary artery disease10.1586/17434440.3.6.731 ↗
13. Optical coherence tomography10.1126/science.1957169 ↗
14. Sensitivity advantage of swept source and Fourier domain optical coherence tomography10.1364/OE.11.002183 ↗
15. The role of optical coherence tomography in the setting of acute myocardial infarction10.1016/j.jjcc.2018.03.004 ↗
16. The role of optical coherence tomography in decision making during the acute phase of spontaneous coronary artery dissection
17. A new technique for lipid core plaque detection by optical coherence tomography for prevention of peri-procedural myocardial infarction: A case report10.1097/MD.0000000000007125 ↗
18. Assessment for ambiguous angiographic finding in patient with acute myocardial infarction by optical coherence tomography10.5603/CJ.2018.0086 ↗
19. Very late stent thrombosis derived from thin-cap neoatheroma and fibroatheroma with plaque rupture assessed by optical coherence tomography10.5603/CJ.2017.0146 ↗
20. Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: A report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation10.1016/j.jacc.2011.09.079 ↗
21. Comparative analysis method of permanent metallic stents (XIENCE) and bioresorbable poly-L-lactic (PLLA) scaffolds (Absorb) on optical coherence tomography at baseline and follow-up10.4244/EIJY15M10_03 ↗
22. An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: A LEADERS trial sub-study10.1093/eurheartj/ehp480 ↗
23. Long-term tissue coverage of a biodegradable polylactide polymer-coated biolimus-eluting stent: Comparative sequential assessment with optical coherence tomography until complete resorption of the polymer10.1016/j.ahj.2011.09.005 ↗
24. OCT guidance during stent implantation in primary PCI: A randomized multicenter study with nine months of optical coherence tomography follow-up10.1016/j.ijcard.2017.10.059 ↗
25. Mechanisms of stent thrombosis analysed by optical coherence tomography: Insights from the national PESTO French registry10.1093/eurheartj/ehv711 ↗
26. Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial10.1016/S0140-6736(11)61672-3 ↗
27. Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: An optical coherence tomography substudy from the RESOLUTE All Comers trial10.1093/eurheartj/ehr182 ↗
28. Comparison of neointimal coverage between zotarolimus-eluting stent and everolimus-eluting stent using Optical Coherence Tomography (COVER OCT)10.1016/j.ahj.2011.10.016 ↗