journal article·2005-09

Development of cementless metal-backed acetabular cup prosthesis using functionally graded material

H. S. Hedia, T. T. El-Midany, M. A. N. Shabara, N. Fouda

Publisher page

Abstract

Metal backing has become widely used in acetaular cup design. A stiff backing for a polyethylene liner was initially believed to be mechanically favorable. Yet, recent studies of the load transfer around acetabular cups have shown that a stiff backing in fact generates higher stress peaks around the acetabular rim than full polyethylene cups, while reduces the stresses transferred at the central part of acetabulum causing stress shielding at the dome of acetabulum. To overcome these two problems, the aim of this study is to improve the design of cementless metal-backed acetabular cup using the two-dimensional functionally graded material concept through a finite element analysis and the optimization techniques. It is found that the optimal 2-D FGM model has three bioactive materials of hydroxyapatite, Bioglass and collagen. This optimal material reduces the stress shielding at the dome of acetabulum by 40% and 37% compared with stainless steel and titanium metal backing shell, respectively. However, using 2-D FGM model reduces the maximum interface shear stress in bone by 31% compared to titanium metal backing shell.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Elasticity and Material Modeling · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. Anderson, B.C., Bloom, P.D., Baikerikar, K.G., Sheares, V.V., Mallapragada, S.K.: Al–Cu–Fe quasicrystal/ultra-high molecular weight polyethylene composites as biomaterials for acetabular cup prosthetics. Biomaterials 23(B), 1761–1768 (2002)Elsevier10.1016/S0142-9612(01)00301-5 ↗
2. Brooks, R.A., Jones, E., Storer, A., Rushton, N.: Biological evaluation of carbon-fibre-reinforced polybutyleneterephthalate (CFRPBT) employed in a novel acetabular cup. Biomaterials 25(17):3429–3438 (2004)Elsevier10.1016/j.biomaterials.2003.10.064 ↗
3. Buma, P., van Loon, P.J.M., Versleyen, H., Weinans, H., Slooff, T.J.J.H., Groot, K., de Huiskes, R.: Histological and biomechanical analysis of bone and interface reactions around hydroxyapatite-coated intramedullary implants of different stiffness: a pilot study of goat. Biomaterials 18:1251–1260 (1997)Elsevier10.1016/S0142-9612(97)00064-1 ↗
4. Cao, W., Hench, L.L.: Bioactive materials. Ceramic Int. 22, 493–507 (1996)10.1016/0272-8842(95)00126-3 ↗
5. De Santis, R., Ambrosio, L., Nicolais, L.: Polymer-based composite hip prostheses. J. Inorg. Biochem. 79, 97–102 (2000)10.1016/S0162-0134(99)00228-7 ↗
6. Dorairajan, A., Reddy, R.M., & Krikler, S. Outcome of acetabular revision using an uncemented hydroxyapatite-coated componenet Two- to five-year results and review. The J. Arthroplasty 20(2), 209–218 (2005)Elsevier10.1016/j.arth.2004.09.049 ↗
7. Fuchiyama, T., Noda, N., Tsuji, T., Obata, Y.: Analysis of thermal stress and stress intensity factor of functionally gradient materials. In: Holt, I.B. et al. (eds.) Ceramic Transactions, Functionally Gradient Materials, vol. 4, pp. 425–432. American Ceramic Society, Westerville OH (1993)
8. Fujimoto T., Noda N.: Multiple crack growths in the functionally graded plate under thermal shock, In: Proceedings of 4th International Congress on Thermal Stresses, Osaka, Japan, pp. 121–124. June 8–11 (2001)
9. Hedia, H.S.: Comparison of One-Dimensional and Two-Dimensional Functionally Graded Materials for the Backing Shell of the Cemented Acetabular Cup. J. Biomed. Mater. Res. Part B: Appl. Biomater. 74B(2), 732–739 (2005)10.1002/jbm.b.30258 ↗
10. Hedia, H.S., Shabara, M.A.N., Elmidany, T.T., Fouda, N.: Improving the performance of the cementless metal-backed acetabular cup prostheses through functionally graded material, 8th International Conference of␣Production Engineering Design and Control, PEDAC’2004, Alexandria, Egypt (2004)
11. Hedia, H.S., Nemat-Alla, M.: Design optimization of functionally graded dental implant. Bio-Medical Materials and Engineering 12(2):133–143 (2004)
12. Hedia, H.S., Abdel Shafi, A.A.A., Fouda, N.: Shape optimization of metal backing for cemented acetabular cup. Biomed. Mat. Eng. 10, 73–82 (2000)
13. Jin, Z., Dowson, D., Fisher, J.: Parametric analysis of contact stress in ultra high molecular weight polyethylene acetabular cups. Med. Eng. Phys. 16, 398–405 (1994)Elsevier10.1016/1350-4533(90)90006-T ↗
14. Khor, K.A., Gu, Y.W., Quek, C.H., Cheang, P.: Plasma spraying of functionally graded hydroxyapatite/Ti–6Al–4V coatings. Surf. Coatings Technol. 168, 195–201 (2003)Elsevier10.1016/S0257-8972(03)00238-X ↗
15. Khorasani, M.T., Zaghiyan, M., Mirzadeh, H.: Ultra high molecular weight polyethylene and polydimethylsiloxane blend as acetabular cup material. Colloids Surf. B: Biointerf. 41(2–3), 169–174 (2005)Elsevier10.1016/j.colsurfb.2004.12.007 ↗