journal article·2024-09-18Open access

Reliability and Validity of the Orthotic Deformation Test

Alejandra Sierra-Rodríguez, Raúl J. Molines-Barroso, M. A. Martínez, Juana Abenojar-Buendía, José Luis Lázaro-Martínez, Angel M. Orejana-García

Applied Sciences· Volume 14· Issue 18

Abstract

The aim of this study was to evaluate the validity of an orthotic deformation test on insole arches and the impact of researcher expertise on the test’s reproducibility. Three researchers with different levels of experience evaluated orthotic deformation by applying a vertical force with their thumb on the dorsal surface of 48 polypropylene orthoses. An electromechanical test machine was used to evaluate the stiffness of the orthoses, and the results were compared with those of the orthotic deformation tests. Fleiss’ kappa and weighted kappa and Mann–Whitney U tests were used to evaluate the interobserver reliability and the validity, respectively. There was no consensus among the three researchers (Kappa = 0.080; p-value = 0.334), although the two researchers with higher levels of experience exhibited moderate consensus (Kappa = 0.52; p-value < 0.001). Orthoses characterised by a positive test suffered from more pronounced deformation when a constant vertical force was applied by the electromechanical test machine (5.62 [4.64–7.38] vs. 4.56 [3.59–5.28] mm; p-value = 0.003). The orthotic deformation test is valid for interpreting the degree of deformation of polypropylene custom orthoses when it is compared with an axial force from a compression-device test. However, considering the high dispersion of the results, it suggests that clinical experience is required to properly interpret the tests.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Foot and Ankle Surgery · Cerebral Palsy and Movement Disorders · Lower Extremity Biomechanics and Pathologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Orthopedic Unit, Clínica Universitaria de Podología, Facultad de Enfermería, Fisioterapia y Podología, Universidad Complutense, 28040 Madrid, Spain

Orthopedic and Diabetic Foot Unit, Facultad de Enfermería, Fisioterapia y Podología, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28040 Madrid, Spain

Materials Science and Engineering Department, Universidad Carlos III de Madrid, Instituto Álvaro Alonso Barba (IAAB), 28911 Leganes, Spain

Mechanical Engineering Department, Universidad Pontificia Comillas, 28004 Madrid, Spain

References (44)

Show source-provided references
1. Manfredi-Márquez, M.J., Tavara-Vidalón, S.P., Tavaruela-Carrión, N., Gómez Benítez, M.A., Fernandez-Seguín, L.M., and Ramos-Ortega, J. (2023). Study of Windlass Mechanism in the Lower Limb Using Inertial Sensors. Int. J. Environ. Res. Public Health, 20.10.3390/ijerph20043220 ↗
2. Function of the plantar fascia10.1054/foot.1999.0520 ↗
3. Stearne, S.M., McDonald, K.A., Alderson, J.A., North, I., Oxnard, C.E., and Rubenson, J. (2016). The Foot’s Arch and the Energetics of Human Locomotion. Sci. Rep., 6.10.1038/srep19403 ↗
4. Tissue stress model. Clinical applications in foot pathology
5. Custom-made foot orthoses for the treatment of foot pain
6. Biomechanical analysis of the effect of orthotic shoe inserts: A review of the literature10.2165/00007256-200029060-00005 ↗
7. Efficacies of different external controls for excessive foot pronation: A meta-analysis10.1136/bjsm.2010.079780 ↗
8. Healy, A., Farmer, S., Pandyan, A., and Chockalingam, N. (2018). A systematic review of randomised controlled trials assessing effectiveness of prosthetic and orthotic interventions. PLoS ONE, 13.10.1371/journal.pone.0192094 ↗
9. Randomized trial of custom orthoses and footwear on foot pain and plantar pressure in diabetic peripheral arterial disease10.1111/j.1464-5491.2009.02799.x ↗
10. A comparison of customised and prefabricated insoles to reduce risk factors for neuropathic diabetic foot ulceration: A participant-blinded randomised controlled trial10.1186/1757-1146-5-31 ↗
11. Ruiz-Ramos, M., Orejana-García, A.M., Vives-Merino, I., Bravo-Llatas, C., Lázaro-Martínez, J.L., and Molines-Barroso, R.J. (2022). Effectiveness of the Fixtoe Device(R) in plantar pressure reduction: A preliminary study. BMC Musculoskelet. Disord., 23.10.1186/s12891-022-05415-5 ↗
12. Zhang, L.Y., Liu, Q.L., Yick, K.L., Yip, J., and Ng, S.P. (2023). Analysis of Diabetic Foot Deformation and Plantar Pressure Distribution of Women at Different Walking Speeds. Int. J. Environ. Res. Public Health, 20.10.3390/ijerph20043688 ↗
13. An insight into the plantar pressure distribution of the foot in clinical practice: Narrative review10.1016/j.poamed.2014.03.003 ↗
14. Haris, F.L., Liau, B.-Y., Jan, Y.-K., Akbari, V.B.H., Primanda, Y., Lin, K.-H., and Lung, C.-W. (2021). A Review of the Plantar Pressure Distribution Effects from Insole Materials and at Different Walking Speeds. Appl. Sci., 11.10.3390/app112411851 ↗
15. Contoured cushioning: Effects of surface compressibility and curvature on heel pressure distribution10.1080/19424280.2010.536587 ↗
16. Foot orthoses for plantar heel pain: A systematic review and meta-analysis10.1136/bjsports-2016-097355 ↗
17. Can foot orthoses impose different gait features based on geometrical design in healthy subjects? A systematic review and meta-analysis10.1016/j.foot.2019.10.001 ↗
19. Arch-support foot-orthoses normalize dynamic in-shoe foot pressure distribution in medial tibial stress syndrome10.1080/17461391.2018.1503337 ↗
20. The Effect of Walking Speed on Foot Kinematics is Modified When Increased Pronation is Induced10.7547/15-120 ↗
21. Contoured, prefabricated foot orthoses demonstrate comparable mechanical properties to contoured, customised foot orthoses: A plantar pressure study10.1186/1757-1146-2-20 ↗
22. Thick shells and medially wedged posts increase foot orthoses medial longitudinal arch stiffness: An experimental study10.1186/s13047-023-00609-z ↗
23. A review on the orthotics and prosthetics and the potential of kenaf composites as alternative materials for ankle-foot orthosis10.1016/j.jmbbm.2019.07.020 ↗
24. Alfaro-Santafé, J., Gómez-Bernal, A., Lanuza-Cerzócimo, C., Alfaro-Santafé, J.V., Pérez-Morcillo, A., and Almenar-Arasanz, A.J. (2021). Effectiveness of Custom-Made Foot Orthoses vs. Heel-Lifts in Children with Calcaneal Apophysitis (Sever’s Disease): A CONSORT-Compliant Randomized Trial. Children, 8.10.21203/rs.3.rs-20702/v1 ↗
25. Experimental and numerical investigation of a polypropylene orthotic device for assistance in level ground walking10.1177/0954411919894091 ↗
26. Rogati, G., Caravaggi, P., Leardini, A., Erani, P., Fognani, R., Saccon, G., Boriani, L., and Baleani, M. (2022). A novel apparatus to assess the mechanical properties of Ankle-Foot Orthoses: Stiffness analysis of the Codivilla spring. J. Biomech., 142.10.1016/j.jbiomech.2022.111239 ↗
27. Comparison of Sagittal Plane Stiffness of Nonarticulated Pediatric Ankle-Foot Orthoses Designed to be Rigid10.1097/JPO.0000000000000383 ↗
28. Choo, Y.J., and Chang, M.C. (2021). Commonly Used Types and Recent Development of Ankle-Foot Orthosis: A Narrative Review. Healthcare, 9.10.3390/healthcare9081046 ↗
29. Kirby, K.A. (2002). Foot and Lower Extremity Biomechanics II: Precision Intricast Newsletters, 1997–2002, Precision Intricast Inc.
30. Silva, R., Veloso, A., Alves, N., Fernandes, C., and Morouço, P. (2022). A Review of Additive Manufacturing Studies for Producing Customized Ankle-Foot Orthoses. Bioengineering, 9.10.3390/bioengineering9060249 ↗
31. An evaluation of personalised insoles developed using additive manufacturing10.1080/02640414.2012.736629 ↗
32. Determination and evaluation of acceptable force limits in single-digit tasks10.1518/0018720024496908 ↗
33. Fatigue Properties of Highly Oriented Polypropylene Tapes and All-Polypropylene Composites
34. Computing inter-rater reliability for observational data: An overview and tutorial. Tutor
35. Surgical anatomy of the midfoot10.1007/s00167-010-1101-9 ↗
36. Longitudinal arch load-sharing system of the foot10.1016/j.repod.2017.03.002 ↗
37. Sichting, F., and Ebrecht, F. (2021). The rise of the longitudinal arch when sitting, standing, and walking: Contributions of the windlass mechanism. PLoS ONE, 16.10.1371/journal.pone.0249965 ↗
38. Function of the windlass mechanism in excessively pronated feet10.7547/87507315-91-5-245 ↗
39. The relationship between navicular drop and first metatarsophalangeal joint motion10.7547/0960313 ↗
40. The windlass mechanism of the foot. A mechanical model to explain pathology10.7547/87507315-90-1-35 ↗
41. Plantar Fasciitis and the Windlass Mechanism: A Biomechanical Link to Clinical Practice
42. Predictive Measurement for Windlass Change in Length and Selected Treatment Outcomes in Chronic Plantar Fasciitis
43. The effect of prefabricated and proprioceptive foot orthoses on plantar pressure distribution in patients with flexible flatfoot during walking10.1177/0309364612461167 ↗
44. Miller, J.N., and Miller, J.C. (2010). Statistics and Chemometrics for Analytical Chemistry, Pearson Education Limited. [6th ed.].