journal article·2024-09-04Open access

Nonlinear Modeling and Transient Stability Analysis of Grid-Connected Voltage Source Converters during Asymmetric Faults Considering Multiple Control Loop Coupling

Jingkuan Guo, Denghui Zhai, Xialin Li, Zhi Wang

Applied Sciences· Volume 14· Issue 17

Abstract

As large-scale renewable energy sources are increasingly integrated into AC grids via voltage source converters (VSCs), the transient synchronization stability of phase-locked loop (PLL)-based VSCs during fault ride-through is gaining more attention. Most existing studies assume that the positive and negative sequence separation and current control dynamics are much faster than the PLL dynamics, thereby neglecting their impact on the transient synchronization stability of the system. However, when the PLL bandwidth is relatively large, ignoring the positive and negative sequence separation and current control dynamics may result in incorrect stability assessments. To address this issue, this paper first considers the multiple control loop coupling, including positive and negative sequence separation, current control, and PLL, to construct a full-order nonlinear mathematical model of the VSC grid-connected system under asymmetric fault conditions. Based on this, the phase trajectory method is employed to analyze the transient synchronization stability of the system. Additionally, this full-order mathematical model is used to determine the PLL bandwidth boundary beyond which the effects of positive and negative sequence separation and current control dynamics cannot be neglected. Finally, PSCAD/EMTDC simulation results validate the effectiveness of the theoretical analysis presented in this paper.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Microgrid Control and Optimization · HVDC Systems and Fault Protection · Islanding Detection in Power Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

China Electric Equipment Group Science and Technology Research Institute Co., Ltd., Shanghai 200040, China

School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China

Funding

China Electrical Equipment Group Corporation Science and Technology Project

References (25)

Show source-provided references
1. Flexible Division and Unification Control Strategies for Resilience Enhancement in Networked Microgrids10.1109/TPWRS.2019.2932939 ↗
2. Revisiting grid-forming and grid-following inverters: A duality theory10.1109/TPWRS.2022.3151851 ↗
3. An Overview of Assessment Methods for Synchronization Stability of Grid-Connected Converters under Severe Symmetrical Grid Faults10.1109/TPEL.2019.2892142 ↗
4. Transient synchronization stability control for LVRT with power angle estimation10.1109/TPEL.2021.3070380 ↗
5. An Iterative Equal Area Criterion for Transient Stability Analysis of Grid-tied Converter Systems with Varying Damping10.1109/TPWRS.2023.3241079 ↗
6. Resynchronization Analysis and Improvement of grid-connected VSCs during grid faults10.1109/JESTPE.2019.2954555 ↗
7. Design-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters10.1109/TPEL.2019.2937942 ↗
8. Transient Stability Analysis of Grid-Following VSCs Considering Voltage-Dependent Current Injection during Fault Ride-Through10.1109/TEC.2022.3204358 ↗
9. Large Signal Synchronizing Instability of PLL-Based VSC Connected to Weak AC Grid10.1109/TPWRS.2019.2892224 ↗
10. Impact of LVRT Control on Transient Synchronizing Stability of PLL-Based Wind Turbine Converter Connected to High Impedance AC Grid10.1109/TPWRS.2022.3223675 ↗
11. Large-Signal Grid-synchronization Stability Analysis of PLL-based VSCs Using Lyapunov’s Direct Method10.1109/TPWRS.2021.3089025 ↗
12. Region of Attraction’s Estimation for Grid Connected Converters with Phase-Locked Loop10.1109/TPWRS.2021.3098960 ↗
13. The Largest Estimated Domain of Attraction and its Applications for Transient Stability Analysis of PLL Synchronization in Weak-Grid-Connected VSCs10.1109/TPWRS.2022.3188887 ↗
14. Analogized Synchronous-Generator Model of PLL-Based VSC and Transient Synchronizing Stability of Converter Dominated Power System10.1109/TSTE.2020.3037155 ↗
15. Transient Synchronization Stability of Grid-Following Converters Considering Nonideal Current Loop10.1109/TPEL.2023.3303447 ↗
16. Transient Synchronization Stability Analysis of Grid-Following Converter Considering the Coupling Effect of Current Loop and Phase Locked Loop10.1109/TEC.2023.3314095 ↗
17. NERC (2017, June 08). 1200 MW Fault Induced Solar Photovoltaic Resource Interruption Disturbance Report—Southern California 8/16/2016 Event. Available online: www.nerc.com.
18. Impact of wind power plant reactive current injection during asymmetrical grid faults10.1049/iet-rpg.2012.0255 ↗
19. Modeling of converter synchronization stability under grid faults: The general case10.1109/JESTPE.2020.3024940 ↗
20. Synchronization Instability of Inverter-Based Generation during Asymmetrical Grid Faults10.1109/TPWRS.2021.3098393 ↗
21. Complex Impedance-Based Frequency Coupling Characteristics Analysis of DFIG-Based WT during Asymmetric Grid Faults10.1109/TIE.2020.3013787 ↗
22. Control and Stability Analysis of Current-Controlled Grid-Connected Inverters in Asymmetrical Grids10.1109/TPEL.2022.3191839 ↗
23. PLL Synchronization Stability of Grid-Connected VSCs Under Asymmetric AC Faults10.1109/TEC.2022.3185667 ↗
24. Analytical Dual-Sequence Current Injections Feasible Region of Weak-Grid Connected VSC under Asymmetric Grid Faults10.1109/TPWRS.2022.3226560 ↗
25. PLL Synchronization Transient Stability Analysis of a Weak-Grid Connected VSC during Asymmetric Faults10.1109/TPEL.2023.3333808 ↗