Evaluation of Thorax Diameter Changes through Trunk Morphology and Different Running Intensities
Source abstract
Abstract
During breathing, the human thorax is expanded or contracted during inspiration and expiration. The morphology of the thorax seems to be determinant for endurance efforts. This study aims to analyse the variation of the thorax cross-sections during running exercises at different intensities and the influence of thorax morphology. Twenty-two athletes were captured using a motion capture system (13 reflective markers) while they performed an incremental running test. Three captures of each subject were performed at different intensities (45%, 70%, and 85% of HRR (heart rate reserve)) and three morphology groups were made by splitting their thoracic index. The results showed a significant increase in the anteroposterior and mediolateral cross-sections when the intensity of the exercise is also increased. No differences were found in the cross-sections due to the morphology of the thorax. However, subjects with a deeper thorax showed a different behaviour as they increased their anteroposterior cross-section during higher intensities, while flatter thorax subjects did not perform in the same way. This could be explained as compensation for the morphological disadvantage that a deeper ribcage shape suffers when developing endurance efforts. More investigations regarding thorax kinematics are needed for a better understanding of breathing disorders and physical activities.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Chronic Obstructive Pulmonary Disease (COPD) Research · Traffic and Road Safety · Effects of Vibration on Health
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Sport Biomechanics Laboratory, Department of Health and Human Performance, Faculty of Physical Activity and Sports Sciences INEF, Universidad Politécnica de Madrid, 28040 Madrid, Spain
Paleobiology Department, Museo Nacional de Ciencias Naturales-Consejo Superior de Investigaciones Científicas, 28006 Madrid, Spain
Funding
CSIC (Consejo Superior de Investigaciones Científicas de España) · Banco Santander Central Hispano SA
References (40)
Show source-provided references
1. In Vivo 3D Analysis of Thoracic Kinematics: Changes in Size and Shape During Breathing and Their Implications for Respiratory Function in Recent Humans and Fossil Hominins10.1002/ar.23503 ↗
2. Zander, T., Pan, F., and Schmidt, H. (2020). Which is the best-suited landmark to assess the thoracic orientation?. J. Biomech., 102.10.1016/j.jbiomech.2019.109545 ↗
3. Kapandji, A. (2007). Fisiología Articular, Editorial Médica Panamericana. [6th ed.].
4. Martins, I., Torres, E., de Castro, A., Massaroni, C., Baroni, G., Cerveri, P., Silvestri, S., Dickinson, J., Jacon, K., and Piaia, A. (2021). Is age rating enough to investigate changes in breathing motion pattern associated with aging of physically active women?. J. Biomech., 125.10.1016/j.jbiomech.2021.110582 ↗
5. Ando, T., Kawamura, K., Fujitani, J., Koike, T., Fujimoto, M., and Fujie, M. (September, January 30). Thoracic ROM measurement system with visual bio-feedback: System design and biofeedback evaluation. Proceedings of the 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA.10.1109/IEMBS.2011.6090299 ↗
6. Comparison of two methods to compute respiratory volumes using optoelectronic plethysmography10.1123/jab.2015-0116 ↗
7. Influence of posture; sex; and age on breathing pattern and chest wall motion in healthy subjects10.1016/j.bjpt.2019.02.007 ↗
8. Efectos de la obesidad sobre el aparato respiratorio
9. Breathing movements of the chest and abdominal wall in healthy subjects10.4187/respcare.01655 ↗
10. Aoki, H., and Nakamura, H. (2018). Non-contact respiration measurement during exercise tolerance test by using kinect sensor. Sports, 6.10.3390/sports6010023 ↗
11. Optoelectronic plethysmography: A review of the literature10.1590/S1413-35552012005000061 ↗
12. Development of a Portable Respiratory Gas Analyzer for Measuring Indirect Resting Energy Expenditure (REE)
13. Houssein, A., Ge, D., Gastinger, S., Dumond, R., and Prioux, J. (2021). A novel algorithm for minute ventilation estimation in remote health monitoring with magnetometer plethysmography. Comput. Biol. Med., 130.10.1016/j.compbiomed.2020.104189 ↗
14. Espinosa, J., and Sánchez-Lafuente, C. (2002). Prueba de Esfuerzo Cardíaca; Respiratoria y Deportiva, EdikaMed. [1st ed.].
15. Optoelectronic Plethysmography in Clinical Practice and Research: A Review10.1159/000462916 ↗
16. Optoelectronic plethysmography derived breathing parameters can differ between athletes with and without a dysfunctional breathing pattern during exercise
17. Assessment of breathing volumes and kinematics by motion capture systems: Comparison of protocols
18. A novel method to compute breathing volumes via motion capture systems: Design and experimental trials10.1123/jab.2016-0271 ↗
19. Analysis of breathing via optoelectronic systems: Comparison of hods for computing breathing volumes and thoraco-abdominal motion pattern10.1080/10255842.2017.1406081 ↗
20. Relationship Between Thoracic Flexibility and Spinal Curvature During Trunk Extension in Healthy Adults10.16965/ijpr.2022.169 ↗
21. Reliability and minimal detectable change of thoracoabdominal mobility measurements using photogrammetry10.1080/09593985.2017.1423525 ↗
22. Effects of gender and posture on thoraco-abdominal kinematics during quiet breathing in healthy adults10.1016/j.resp.2010.05.018 ↗
23. Effects of posture on chest-wall configuration and motion during tidal breathing in normal men10.1589/jpts.29.29 ↗
24. Three-dimensional optical analysis of chest wall motion10.1152/jappl.1994.77.3.1224 ↗
25. Chest wall and lung volume estimation by optical reflectance motion analysis10.1152/jappl.1996.81.6.2680 ↗
26. Development of a Bio-Inspired Mechatronic Chest Wall Simulator for Evaluating the Performances of Opto-Electronic Plethysmography10.2174/1874120701408010120 ↗
27. Chest Wall Kinematics Using Triangular Cosserat Point Elements in Healthy and Neuromuscular Subjects10.1007/s10439-017-1840-6 ↗
28. Massaroni, C., Cassetta, E., Levai, I., Winter, S., Dickinson, J., and Silvestri, S. (2016, January 16–20). Optical measurement of breathing: Algorithm volume calibration and preliminary validation on healthy trained subjects. Proceedings of the 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA.10.1109/EMBC.2016.7591155 ↗
29. Optoelectronic plethysmography has improved our knowledge of respiratory physiology and pathophysiology10.3390/s8127951 ↗
30. Comparison of marker models for the analysis of the volume variation and thoracoabdominal motion pattern in untrained and trained participants10.1016/j.jbiomech.2018.05.036 ↗
31. Stubbe, L., Houel, N., and Cottin, F. (2022). Accuracy and reliability of the optoelectronic plethysmography and the heart rate systems for measuring breathing rates compared with the spirometer. Sci. Rep., 12.10.1038/s41598-022-23915-1 ↗
32. Bastir, M., González-Ruíz, J., Rueda, J., Garrido-López, G., Gómez-Recio, M., Beyer, B., San Juan, A.F., and Navarro, E. (2022). Variation in human 3D trunk shape and its functional implications in hominin evolution. Sci. Rep., 12.10.1038/s41598-022-15344-x ↗
33. Geometric morphometrics of 4D motion data: A proof of concept for applications in palaeoanthropology10.7203/sjp.25648 ↗
34. Hamill, J., Knutzen, K., and Derrick, T. (2003). Biomechanical Basis of Human Movement, Wolters Kluwer. [4th ed.].
35. The thoracic index
36. Thoracic index in adults with asthma: A study of validity and reliability10.1186/s12998-018-0187-x ↗
37. A Power Primer10.1037/0033-2909.112.1.155 ↗
38. Respiratory kinematics by optoelectronic plethysmography during exercise in men and women10.1007/s00421-004-1249-4 ↗
39. Action of the diaphragm on the rib cage10.1152/japplphysiol.00268.2016 ↗
40. Respiratory frequency as a marker of physical effort during high-intensity interval training in soccer players10.1123/ijspp.2019-0028 ↗