A Brief Report on the Role of SPECT/TC in the Optimization of Radiotherapy Treatment with Radical Intent for Unresectable Stage III NSCLC
Source abstract
Abstract
Background: The standard treatment for locally advanced non-small cell lung cancer (LA-NSCLC) is represented by concomitant chemo-radiotherapy followed by consolidation with durvalumab that ensures a 5-year survival of 46%. However, the risk of radiotherapy-induced pneumonia (RIP) is almost 10–15%. Complete cardiological examination is also usually performed during the cardiopulmonary pre-treatment evaluation and pulmonary function testing is one of the most used tool to predict the risk of RIP development. Aim: The aim of this study is to investigate the impact of Tc-99 macroaggregated albumin (MAA) lung perfusion scan with single photon emission-computed tomography/computed tomography (SPECT/CT) in the preliminary assessment of lung functions and its potential role for the optimization of the radiotherapy treatment planning. Methods: Descriptive and statistical analysis were performed on eight patients affected by unresectable stage III LA-NSCLC treated with chemo-radiotherapy. Before starting radiotherapy, patients underwent lung perfusion SPECT/CT. The SPECT/CT images were firstly co-registered with the simulation CT scan ones, then a specific region of interest (ROI) of lung volumes was created to represent the areas with a perfusion of at least 20% 40%, 60% and 80% of maximum perfusion, respectively. Finally, optimization of the standard treatment plan was performed with the aim of preserving the better perfused lung volumes. The dosimetric correlations of both plans were made comparing pulmonary V20 and V5, mean pulmonary, esophagus and heart dose. Results: From the DVH comparative analysis of the two treatment plans (standard one versus SPECT optimized one) obtained for each patient, the data confirmed an equal coverage of the target volume while respecting all lungs, heart and esophagus dose constraints. At the same time, SPECT-optimized plans allowed to reduce the average dose to the better perfused lung volumes. Conclusions: Lung perfusion scintigraphy could be considered a preliminary assessment tool to explore lung functions and stratify the risk of RIP development. SPECT/TC may also be proposed as a dose painting tool to optimize radiotherapy treatment plans. Only prospective analysis will be enable us to confirm the real reduction of RIP risk in lung areas with an optimal perfusion.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Lung Cancer Diagnosis and Treatment · Advanced Radiotherapy Techniques · Medical Imaging Techniques and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Radiotherapy Unit, Department of Oncology and Hematology, University Hospital of Modena, 41125 Modena, Italy
Department of Radiation Oncology, University ASST Spedali Civili of Brescia, 25123 Brescia, Italy
Nuclear Medicine, University of Brescia and Spedali Civili of Brescia, 25121 Brescia, Italy
Medical Physics Unit, University ASST Spedali Civili di Brescia, 25123 Brescia, Italy
Oncology, University ASST Spedali Civili of Brescia, 25123 Brescia, Italy
References (18)
Show source-provided references
1. Five-Year Survival Outcomes From the PACIFIC Trial: Durvalumab After Chemoradiotherapy in Stage III Non–Small-Cell Lung Cancer10.1200/JCO.21.01308 ↗
2. Corrigendum: A Real-World, Multicenter, Observational Retrospective Study of Durvalumab After Concomitant or Sequential Chemoradiation for Unresectable Stage III Non-Small Cell Lung Cancer10.3389/fonc.2021.802949 ↗
3. Impact of Intensity-Modulated Radiation Therapy Technique for Locally Advanced Non–Small-Cell Lung Cancer: A Secondary Analysis of the NRG Oncology RTOG 0617 Randomized Clinical Trial10.1200/JCO.2016.69.1378 ↗
4. Toxicity and outcome results of RTOG 9311: A phase I–II dose-escalation study using three-dimensional conformal radiotherapy in patients with inoperable non–small-cell lung carcinoma10.1016/j.ijrobp.2004.06.260 ↗
5. Are the Results of RTOG 0617 Mysterious?10.1016/j.ijrobp.2011.12.032 ↗
6. National Cancer Institute Common Terminology Criteria for Adverse Events: CTCAE.
7. Prediction of Pulmonary Function Loss Due to Pneumonectomy Using 133Xe-Radiospirometry10.1378/chest.62.6.694 ↗
8. The Role of Functional Imaging in the Diagnosis and Management of Late Normal Tissue Injury10.1016/j.semradonc.2006.11.003 ↗
9. Inclusion of functional information from perfusion SPECT improves predictive value of dose–volume parameters in lung toxicity outcome after radiotherapy for non-small cell lung cancer: A prospective study10.1016/j.radonc.2015.08.005 ↗
10. Clinical dose–volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC)10.1016/S0360-3016(99)00183-2 ↗
11. Predictive value of dose-volume histogram parameters for predicting radiation pneumonitis after concurrent chemoradiation for lung cancer10.1016/S0360-3016(02)03807-5 ↗
12. ESTRO ACROP guidelines for target volume definition in the treatment of locally advanced non-small cell lung cancer10.1016/j.radonc.2018.02.023 ↗
13. Der ICRU-Report 83: Verordnung, Dokumentation und Kommunikation der fluenzmodulierten Photonenstrahlentherapie (IMRT) [The ICRU Report 83: Prescribing, recording and reporting photon-beam intensity-modulated radiation therapy (IMRT)]10.1007/s00066-011-0015-x ↗
14. Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC): An Introduction to the Scientific Issues10.1016/j.ijrobp.2009.09.040 ↗
15. SPECT-based functional lung imaging for the prediction of radiation pneumonitis: A clinical and dosimetric correlation10.1111/1754-9485.12145 ↗
16. The Effects of Applying Apparent Diffusion Coefficient Parameters on the Differentiation between Fourth Ventricular Ependymoma and Diffuse Intrinsic Pontine Glioma10.1055/s-0040-1718897 ↗
17. The Role of Apparent Diffusion Coefficient in the Differentiation between Cerebellar Medulloblastoma and Brainstem Glioma10.3390/neurolint12030009 ↗
18. Ga-68 MAA Perfusion 4D-PET/CT Scanning Allows for Functional Lung Avoidance Using Conformal Radiation Therapy Planning10.1177/1533034614565534 ↗