Abstract

The aspirating smoke detector (ASD) is one of the most critical pieces of equipment for detecting smoke in a protected area when a fire occurs. It has more advantages than a conventional smoke detector because it can be used in extreme conditions, such as cold storage facilities or hot aisle containment areas. ASD uses a fan to draw air from the protected area into the pipe network system via pipe holes. The sucked air is transported into the sensing chamber to detect smoke. If the obscuration in the sensing chamber is greater than the setpoint, the ASD will sound an alarm so that people realize there is a fire. For this reason, investigating the effect of the pipe hole network on obscuration in the ASD is critical. In this study, a Pipe Hole Network Program was developed to consider the pipe flow parameter. A numerical study based on the program and an experimental study was performed. The results showed that the numerical results had the same trend as the experimental study. The further the location of the fire source was, the lower the obscuration was. In addition, the correlation between the obscuration parameter and the fire source distance was also derived. It could be used to predict the fire source location in the aspirating smoke detection system.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire Detection and Safety Systems · Evacuation and Crowd Dynamics · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Mechanical Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 06974, Korea

Alllitelife Company, 199-32, Anyang-dong, Manan-gu, Anyang-si 14087, Korea

Funding

National Fire Agency

References (31)

Show source-provided references
1. The Simulation of the Sampling Pipes and Sampling Holes Network with an Aspirating Smoke Detector
2. Pressure drop in pipe lines for compressed air: Comparison between experimental and theoretical analysis
3. Pressure Losses Analysis in Air Duct Flow Using Computational Fluid Dynamics (CFD)
4. Teaching turbulent flow through pipe fittings using computational fluid dynamics approach10.1002/eng2.12093 ↗
5. CFD modeling for the estimation of pressure loss coefficients of pipe fittings: An undergraduate project10.1002/cae.21695 ↗
6. Singh, R.K. (2009). A Study of Air Flow in a Network of Pipes Used in Aspirated Smoke Detectors. [Ph.D. Thesis, Victoria University].
7. Analytical and experimental study on complex compressed air pipe network10.3901/CJME.2015.0515.071 ↗
8. Simulation investigation on the smoke spread process in the large-space building with various height10.1016/j.csite.2020.100594 ↗
9. Numerical simulation of the variation of obscuration ratio at the fire early phase with various soot yield rate10.1016/j.csite.2019.100572 ↗
10. Zhenna, Z., Qin, Z., Hongbing, C., Suilin, W., and Hongwen, L. (2012). Performance study on fire alarm system in large space buildings. Recent Advances in Computer Science and Information Engineering, Springer.10.1007/978-3-642-25781-0_11 ↗
11. Krope, J., Dobersek, D., and Goricanec, D. (2006, January 18–20). Flow pressure analysis of pipe networks with linear theory method. Proceedings of the 2006 WSEAS/IASME International Conference on Fluid Mechanics, Miami, FL, USA.
12. Air flow modeling in a prototype sanitary sewer system10.1061/(ASCE)EE.1943-7870.0001342 ↗
13. Quraishi, M.S. (1996, January 9–12). Prediction of fan assisted flow in a duct/pipe network. Proceedings of the 1996 CNA/CNS Conference, Fredericton, NB, Canada.
14. Brkić, D., and Praks, P. (2019). An efficient iterative method for looped pipe network hydraulics free of flow-corrections. Fluids, 4.10.20944/preprints201903.0067.v1 ↗
15. Lang, S. (2012). Variable Air Speed Aspirating Smoke Detector. (8,098,166), U.S. Patent.
16. Nagy, T., Jílek, A., and Pečínka, J. (June, January 31). Air flow rate measurement with various differential pressure methods. Proceedings of the 2017 International Conference on Military Technologies (ICMT), Brno, Czech Republic.10.1109/MILTECHS.2017.7988816 ↗
17. Anantharaman, V., Waterson, N., Nakiboglu, G., Persin, M., and van Oudheusden, B. (2016, January 4–6). Experimental investigation of turbulent flow through single-hole orifice placed in a pipe by means of time-resolved Particle Image Velocimetry and unsteady pressure measurements. Proceedings of the 11th International Conference on Flow-Induced Vibrations, Den Haag, The Netherlands.
18. Numerical modelling of early flame spread in warehouse fires10.1016/0379-7112(95)00022-L ↗
19. Lönnermark, A., and Ingason, H. (2005). Fire Spread in Large Industrial Premises and Warehouse, SP Swedish National Testing and Research Institute.
20. Muckett, M., and Furness, A. (2007). Introduction to Fire Safety Management, Routledge.10.4324/9780080551791 ↗
21. Liu, S., Luo, X., Yao, W., Chen, C., Kun, Y., Yi, M., Hu, H., and Zhang, Y. (2014, January 26–28). Aspirating fire detection system with high sensitivity and multi-parameter. Proceedings of the 2014 International Conference on Information Science, Electronics and Electrical Engineering, Sapporo, Japan.
22. Shaltout, R.E., and Ismail, M.A. (2020). Simulation of Fire Dynamics and Firefighting System for a Full-Scale Passenger Rolling Stock. Sustainable Rail Transport, Springer.10.1007/978-3-030-19519-9_7 ↗
23. Very Early Smoke Detection Apparatus (VESDA), David Packham, John Petersen, Martin Cole: 2017 DiNenno Prize10.1186/s40038-017-0019-4 ↗
24. Simulation Study on the Aspirating Smoke Detection System in Large Space Buildings10.4028/www.scientific.net/AMR.255-260.1404 ↗
25. Brown, G.O. (2002, January 3–7). The history of the Darcy-Weisbach equation for pipe flow resistance. Proceedings of the Environmental and Water Resources History Sessions at ASCE Civil Engineering Conference and Exposition, Washington, DC, USA.10.1061/40650(2003)4 ↗
26. Cole, M. (1999). Disturbance of Flow Regimes by Jet Induction. [Ph.D. Thesis, Victoria University of Technology].
27. Munson, B.R., Young, D.F., and Okiishi, T.H. (1998). Fundamentals of Fluid Mechanics, John Wiley & Sons.
28. Fire dynamics simulator (version 5) technical reference guide
29. Fabian, T.Z., and Gandhi, P.D. (2007). Smoke Characterization Project, Fire Protection Research Foundation/Underwriters Laboratories, Incorporated.
30. Miller, J.H.T. (2010). Analyzing Photo-Electric Smoke Detector Response Based on Aspirated Smoke Detector Obscuration, University of Maryland.
31. (2022, January 26). Securition: SecuriSmoke ASD Aspirating Smoke Detectors the Complete Model Range for Any Application. Available online: https://www.securiton.com/products-services/smoke-detection-systems/securismoke-asd.