In vivo characterization of attachment safety between cardiac pacing lead and canine heart muscle
Source abstract
Abstract
ABSTRACT In vivo experiments of screwing the electrode of canine hearts and assigning external excitation on the lead-myocardium interface was carried out to evaluate the lead/myocardium adherence safety. The electrode is specially designed to host a measurement unit of strain gauges. We obtained the lead/heart interactions data from12 dogs under natural heart beating and beating with external excitations. The data recorded from the acute phase and the chronic phase of pulling out pacing leads were compared with each other. The electrode/heart interaction is caused by the heart beat and influenced by the lung breath. This process induced tolerable damage to the lead or myocardium. The interaction decreases as the frequency of external excitations increases. The lead is more likely to be detached from myocardium under higher excitation frequency. At the same implanting sites, safer pacing lead/myocardium attachment can be realized in the chronic tests than in the acute tests.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Cardiac pacing and defibrillation studies · Cardiomyopathy and Myosin Studies · Neuroscience and Neural Engineering
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (10)
Show source-provided references
1. Gabriel, M.D., Indications and Recommendations for Pacemaker Therapy. American Family Physician, 2005, 71: 1563–1571.
2. Moulton, M.J., Creswell, L.L. and Actis, R.L., An inverse approach to determining myocardial material properties. Journal of biomechanics, 1995, 28: 935–948.10.1016/0021-9290(94)00144-S ↗
3. Guccione, J.M., Costa, K.D. and McCullonch, A.D., Finite element stress analysis of left ventricular mechanics in the beating dog heart. Journal of biomechanics, 1995, 28: 1167–1177.10.1016/0021-9290(94)00174-3 ↗
4. Nobel, D., The development of mathematical models of the heart. Chaos, Solitons and Fractals, 1995, 5: 321–333.10.1016/0960-0779(93)E0025-7 ↗
5. Hunter, P.J., McCullonch, A.D., Keurs, H.J., et al., Modeling the mechanical properties of cardiac muscle. Progress in biophysics and molecular biology, 1998, 69: 289–331.10.1016/S0079-6107(98)00013-3 ↗
6. Baxter, W.W. and McCulloch, A.D., In vivo finite element model-based image analysis of pacemaker lead mechanics. Medical Image Analysis, 2001, 5: 255–270.10.1016/S1361-8415(01)00041-X ↗
7. Zhao, Y., Challenges in modeling implantable medical devices//Proceedings of ABAQUS User Conference 2001, 641–654.
8. Smith, N.P., Mulquiney, P.J., Nash, M.P., Bradley, C.P., Nickerson, D.P. and Hunter, P.J., Mathematical modeling of the heart: cell to organ. Chaos, Solitons and Fractals, 2002, 13: 1613–1621.10.1016/S0960-0779(01)00170-9 ↗
9. Remme, E.W., Hunter, P.J., Smiseth Otto, et al., Development of an in vivo method for determining material properties of passive myocardium. Journal of biomechanics, 2004, 37: 669–678.10.1016/j.jbiomech.2003.09.023 ↗
10. Zhang, J.Y., Chen, S.J., Cooke, D.J., et al., Analysis Of intracardiac lead bending stress and motion characteristics of RVA versus RVOS pacing leads using an innovative 3-D reconstruction technique//2003 Summer Bioengineering Conference, June 25–29, Sonesta Beach Resort in Key Biscayne, Florida.