Electrophoretic Protein Deposition as a Tool for In Situ Co-Crosslinking Enzyme Immobilization: An Electrochemical/Quartz Crystal Microbalance Study
Source abstract
Abstract
Electrophoretic deposition is a powerful tool for depositing materials onto a substrate by using an electric field; its application in biotechnological areas, namely, electrophoretic protein deposition (EPD), is the most promising for, e.g., fabricating novel amperometric biosensors. Unfortunately, EPD suffers from several drawbacks due to coupled parasite electrochemical processes damaging the deposit; moreover, the nature of the deposition process, the deposit, and its stability are still controversial and unknown. The present research presents a deep investigation of the EPD processes conducted by using several electroanalytical techniques and an electrochemical quartz crystal microbalance (EQCM); notably, EPD was used here as a novel tool for performing an electrophoretically assisted, classical enzyme immobilization technique like co-crosslinking, thus permitting the immobilization of the desired protein in situ, i.e., exclusively onto the deposition electrode. An electrochemical study permitted the acquisition of useful insights about electrophoresis processes as well as solvent discharge and gas evolution at the deposition electrode; further, the use of appropriate current or potential pulse sequences, as investigated and improved in this study, together with fine-tuned chemical conditions, allowed the optimization of this novel EPD approach. Moreover, an EQCM study gave useful insights into the kinetics of the process, permitting a quantitative estimate of the deposit.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrophoretic Deposition in Materials Science · Quantum Dots Synthesis And Properties · Chalcogenide Semiconductor Thin Films
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Dipartimento di Scienze, Università Degli Studi Della Basilicata, Via Dell’ateneo Lucano 10, 85100 Potenza, Italy
Funding
Ministero dell’Istruzione, dell’Università e della Ricerca Italiana (MIUR)
References (34)
Show source-provided references
1. Current Status of Ceramic Coatings for Dental Implants10.1097/00008505-199807040-00010 ↗
2. Electrophoretic deposition of biomaterials10.1098/rsif.2010.0156.focus ↗
3. Electrophoretic deposition of biological macromolecules, drugs, and cells10.1021/bm401021b ↗
4. Electrochemical and electrophoretic deposition of enzymes: Principles, differences and application in miniaturized biosensor and biofuel cell electrodes10.1016/j.bios.2014.02.030 ↗
5. Electrophoretic deposition: A versatile tool against biomaterial associated infections10.1039/C7TB02445B ↗
6. Electrophoretic deposition of polymers and proteins for biomedical applications10.1016/j.cis.2020.102272 ↗
7. Reproducible electrodeposition of biomolecules for the fabrication of miniature electroenzymatic biosensors10.1016/0925-4005(91)80225-9 ↗
8. Electrodeposition of glucose oxidase for the fabrication of miniature sensors10.1016/0925-4005(93)85323-3 ↗
9. Usmani, A.M., and Akmal, N. (1994). Diagnostic Biosensor Polymers, American Chemical Society.10.1021/bk-1994-0556 ↗
10. Development of needle-type glucose sensor with high selectivity10.1016/S0925-4005(98)00126-9 ↗
11. Enzyme modified microband electrodes: Cross-talk effects and their elimination10.1039/b101529j ↗
12. Fundamental studies of glucose oxidase deposition on a Pt electrode10.1021/ac015536x ↗
13. AC-electrophoretic deposition of glucose oxidase10.1016/j.bios.2009.06.036 ↗
14. Electrochemical techniques for the modification of microelectrodes10.1016/0956-5663(95)96794-Y ↗
15. Two-enzyme lactose biosensor based on β-galactosidase and glucose oxidase deposited by AC-electrophoresis: Characteristics and performance for lactose determination in milk10.1016/j.snb.2010.05.027 ↗
16. Highly sensitive and selective glutamate microbiosensor based on cast polyurethane/AC-electrophoresis deposited multiwalled carbon nanotubes and then glutamate oxidase/electrosynthesized polypyrrole/Pt electrode10.1016/j.bios.2009.11.020 ↗
17. AC-electrophoretic deposition of metalloenzymes: Catalase as a case study for the sensitive and selective detection of H2O210.1016/j.snb.2011.09.027 ↗
18. Silver Nanoparticle-Enzyme Composite Films for Hydrogen Peroxide Detection10.1021/acsanm.9b01346 ↗
19. Performance Enhancement of Polypyrrole Based Nano-Biosensors by Different Enzyme Deposition Techniques10.1007/978-3-319-99540-3_11 ↗
20. Amperometric detection of phenolic compounds with enzyme immobilized in mesoporous silica prepared by electrophoretic deposition10.1016/j.snb.2010.10.048 ↗
21. Schlesinger, M., and Paunovic, M. (2010). Modern Electroplating, Wiley.10.1002/9780470602638 ↗
22. A study on electrodeposition of glucose oxidase from low conductivity solutions10.1016/j.electacta.2010.08.050 ↗
23. Electrodeposited GOD/BSA electrodes: Ellipsometric study and glucose-sensing behaviour10.1016/0925-4005(95)85032-5 ↗
24. Zaborsky, O. (1973). Immobilized Enzymes, CRC Press.
25. Wiseman, A. (1985). Handbook of Enzyme Biotechnology, Ellis Horwood Lim., John Wiley & Sons.
26. Electrosynthesized non-conducting polymers as permselective membranes in amperometric enzyme electrodes: A glucose biosensor based on a co-crosslinked glucose oxidase/overoxidized polypyrrole bilayer10.1016/S0956-5663(97)00064-X ↗
27. Amperometric sensor for choline and acetylcholine based on a platinum electrode modified by a co-crosslinked bienzymic system10.1039/an9952002731 ↗
28. An Acetylcholinesterase/Choline Oxidase-Based Amperometric Biosensor as a Liquid Chromatography Detector for Acetylcholine and Choline Determination in Brain Tissue Homogenates10.1021/ac000852h ↗
29. The kinetic and analytical behaviours of an l-lysine amperometric biosensor based on lysine oxidase immobilised onto a platinum electrode by co-crosslinking10.1016/j.snb.2007.03.025 ↗
30. A novel amperometric biosensor based on a co-crosslinked l-lysine-α-oxidase/overoxidized polypyrrole bilayer for the highly selective determination of l-lysine10.1016/j.aca.2013.07.036 ↗
31. A novel approach for the selective analysis of L-lysine in untreated human serum by a co-crosslinked L-lysine–α-oxidase/overoxidized polypyrrole bilayer based amperometric biosensor10.1016/j.bioelechem.2018.07.004 ↗
32. Kinetic measurements on a stationary disk electrode in a uniformly rotating fluid (SDERF)—I. The limiting diffusion current in the Fe(CN)4−6-Fe(CN)3−6-system10.1016/0013-4686(78)80093-0 ↗
33. Calibration of the Electrochemical Quartz Crystal Microbalance10.1149/1.2086033 ↗
34. Quartz crystal microbalance: A useful tool for studying thin polymer films and complex biomolecular systems at the solution-surface interface10.1021/bm020116i ↗