Luminosity and Contrast Adjustment of Fundus Images with Reflectance
Source abstract
Abstract
This paper presents an automatic correction method for luminosity and contrast variation in fundus images. Sixty retina or fundus images with different levels of reflectance are selected from online databases and used to assess the effectiveness of the proposed method. There are five stages in the approach, and they are image input, filtering, luminosity correction, histogram stretching and post-processing. First, a color fundus image is read as input, and its three color components, red (R), green (G) and blue (B), are separated into different channels or arrays. Next, the eye region, or the region of interest (ROI), is identified along with its border via thresholding. After that, the original ratios of red-to-green and blue-to-green for every pixel in the ROI are computed and kept together with copies of the three channels. Then, the ROI for the three channels is subjected to lowpass filtering, row-wisely in the horizontal direction and column-wisely in the vertical direction, to create a smooth background luminosity surface. This surface does not contain foreground objects such as blood vessels, optic discs, lesions, microaneurysms and others. Three lowpass filters are tested for this purpose, and their efficacy is compared. The outcome is a smooth luminosity surface that estimates the background illumination of the entire ROI. Once the background illumination is established, the luminosity is equalized for all pixels in the ROI, such that every pixel will have the same background brightness. Afterward, the histogram of the ROI is stretched or equalized to enhance the contrast between the foreground objects and the background. Next, the green channel is further improved by adding details from the blue and red channels. Finally, in the post-filtering stage, the intensities of the blue and red channels are adjusted according to their original ratios to the green channel. When all three channels are recombined, the resulting color image looks similar to the original image but shows improved luminosity and contrast. The method is tested on 60 test images. It reduces luminosity variation and increases the contrast of all images. On average, this method achieves a 30% reduction in luminosity variation and a 90% increment in contrast. The proposed method was executed on AMD 5900HS CPU using MATLAB R2021b, and the mean execution time was nearly 2 s on average.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Retinal Imaging and Analysis · Retinal Diseases and Treatments · Retinal and Optic Conditions
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia
References (22)
Show source-provided references
1. Fundus image lesion detection algorithm for diabetic retinopathy screening10.1007/s12652-020-02417-w ↗
2. Enhanced Detection of Reticular Pseudodrusen on Color Fundus Photos by Image Embossing10.1080/02713683.2022.2126860 ↗
3. A comprehensive review on automated systems for severity grading of diabetic retinopathy and macular edema10.1002/ima.22574 ↗
4. Automatic detection of diabetic retinopathy with statistical method and Bayesian classifier10.1166/jmihi.2020.3025 ↗
5. An approach for de-noising and contrast enhancement of retinal fundus image using CLAHE10.1016/j.optlastec.2018.06.061 ↗
6. Glaucoma detection using image processing techniques: A literature review10.1016/j.compmedimag.2019.101657 ↗
7. Major automatic diabetic retinopathy screening systems and related core algorithms: A review10.1007/s00138-018-00998-3 ↗
8. An improved luminosity and contrast enhancement framework for feature preservation in color fundus images10.1007/s11760-018-1401-y ↗
9. Diabetic retinopathy detection through convolutional neural networks with synaptic metaplasticity10.1016/j.cmpb.2021.106094 ↗
10. Automated detection of microaneurysms in color fundus images using deep learning with different preprocessing approaches
11. Retinal image enhancement using low-pass filtering and α-rooting10.1016/j.sigpro.2019.107445 ↗
12. Automated microaneurysms detection for early diagnosis of diabetic retinopathy: A Comprehensive review10.1016/j.cmpbup.2021.100013 ↗
13. Microaneurysm detection using fully convolutional neural networks10.1016/j.cmpb.2018.02.016 ↗
14. Color retinal image enhancement based on luminosity and contrast adjustment10.1109/TBME.2017.2700627 ↗
15. A hybrid method for improving the luminosity and contrast of color retinal images using the JND model and multiple layers of CLAHE10.1007/s11760-022-02223-1 ↗
16. Dissopa, J., Kansomkeat, S., and Intajag, S. (2021). Enhance Contrast and Balance Color of Retinal Image. Symmetry, 13.10.3390/sym13112089 ↗
17. Contrast and color balance enhancement for non-uniform illumination retinal images10.31803/tg-20191104185229 ↗
18. Qureshi, I., Ma, J., and Shaheed, K. (2019). A hybrid proposed fundus image enhancement framework for diabetic retinopathy. Algorithms, 12.10.3390/a12010014 ↗
19. A hybrid algorithm to enhance colour retinal fundus images using a Wiener filter and CLAHE10.1007/s10278-021-00447-0 ↗
20. Enhancement of blurry retinal image based on non-uniform contrast stretching and intensity transfer10.1007/s11517-019-02106-7 ↗
21. Luminosity and contrast enhancement of retinal vessel images using the weighted average histogram10.1016/j.bspc.2021.103089 ↗
22. Matkovic, K., Neumann, L., Neumann, A., Psik, T., and Purgathofer, W. (2005). Computer Aesthetics in Graphics, Visualization and Imaging, The Eurographics Association.