Filament X-ray Tube Current Control Method Using Indirect Filament Temperature Estimation
Source abstract
Abstract
The recent increase in ailments has increased the demand for diagnosis and surgery based on X-rays. An X-ray system using a filament-type tube heats the filament for operation, and the electrons emitted by the thermal energy during this process produce X-rays. Conventionally, current control-based methods are used to regulate heating. However, these methods do not control the temperature of the filament, resulting in lower or higher output than the desired dose rate. Therefore, we propose a filament temperature control method that enables constant temperature control, which cannot be achieved using the existing heating method for X-ray systems with filament tubes. Additionally, we developed an indirect temperature estimation algorithm for the tungsten filament to incorporate the proposed method. To validate the tube current control through temperature control, we performed experiments to compare the existing current-controlled heating and temperature control methods in terms of the filament temperature. As the tube current is proportional to the dose rate, it was measured through a comparative analysis of the change in the output of dose rate over time. The obtained results validate that the proposed method can maintain both the filament temperature and tube current at the desired level.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Radiotherapy Techniques · Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electrical Engineering, Konkuk University, Seoul 05029, Korea
References (21)
Show source-provided references
1. X-ray imaging physics for nuclear medicine technologists. Part 1: Basic principles of X-ray production
2. X-ray tubes development-IOMP history of medical physics
3. Commentary: Worldwide knowledge and attitude of spine surgeons regarding radiation exposure10.1093/neuros/nyy243 ↗
4. The AAPM/RSNA physics tutorial for residents fluoroscopy: Patient radiation exposure issues 110.1148/radiographics.21.4.g01jl271033 ↗
5. Bushberg, J.T., Seibert, J.A., Leidholdt, E.M., and Boone, J.M. (2001). The Essential Physics of Medical Imaging, Lippincott Williams & Wilkins. [2nd ed.].
6. Kim, Y.J., Maruyama, Y., and Nakaoka, M. (1993, January 20–24). Practical evaluations of resonant pole-assisted ZVS-PWM DC/DC converter with series capacitor-connected transformer parasitic parallel resonant tank. Proceedings of the Annual IEEE Power Electronics Specialist Conference, Seattle, WA, USA.
7. Seo, Y.M., Byun, M.S., and Hong, S.C. (2015, January 1–5). Hybrid type X-ray generator for fluoroscopy X-ray system available in low-capacity AC power source. Proceedings of the 9th International Conference Power Electronics, Seoul, Korea.10.1109/ICPE.2015.7168193 ↗
8. Filament power supply for electron beam welding machine10.1109/TIE.2014.2362730 ↗
9. Sasic, B., Pindrys, S., and Willsey, J. (2018). Functional Role of X-ray Generators in Industrial Applications, Spellman High Voltage Electronics Corporation.
10. Quality control and radiation dose rates measurement from diagnostic X-ray examination at different places of hospitals in Sulaimania
11. Bruno, A.C., Mazaro, S.J., Amaral, L.L., Rego, E.M., Oliveira, H.F., and Pavoni, J.F. (2017). Biological X-ray irradiator characterization for use with small animals and cells. Braz. J. Med. Biol. Res., 50.10.1590/1414-431x20165848 ↗
12. Nottingham, W.B. (1956). Thermionic Emission, The Research Laboratory of Electronics Massachusetts Institute of Technology.10.1007/978-3-642-45844-6_1 ↗
13. Schonenberger, C., and Oberholzer, S. (2004). Shot Noise: From Schottky’s Vacuum Tube to Present-Day Quantum Devices. Fluctuations and Noise in Materials (Proceedings of SPIE), SPIE.10.1117/12.544211 ↗
14. Resistance and radiation of tungsten as a function of temperature10.1364/JOSA.24.000114 ↗
15. Zerda, T.W. (2013). Stefan Boltzmann Lamp 1008523, 3B Scientific Physics.
16. Shabalin, I.L. (2014). Ultra High Temperature Materials, Springer.10.1007/978-94-007-7587-9 ↗
17. High speed (subsecond) measurement of heat capacity, electrical resistivity, and thermal radiation properties of tungsten in the range 2000 to 3600 K10.6028/jres.075A.027 ↗
18. Temperature dependence of thermal conductivity in W and W–Re alloys from 300 to 1000 K10.1016/S0167-577X(02)01403-9 ↗
19. Borgea, S., Campbell, N., Gomes, A., Raszkowski, A.M., Rook, J.W., Sanderud, A., Vallinga, A., Vouillamoz, A., and Buissink, C. (2014, January 1–31). Experimental article—Maintaining image quality for pediatric chest CTs while lowering dose: FBP versus SAFIRE. Reconstruction in CT. Proceedings of the OPTIMAX 2014: Radiation Dose and Image Quality Optimisation in Medical Imaging, Portugal, Lisbon.
20. Evaluation of heat transfer coefficient of tungsten filaments at low pressures and high temperatures10.1016/j.applthermaleng.2010.09.005 ↗
21. Real-time measurement of dynamic filament resistance10.1080/00994480.1998.10748207 ↗