journal article·2021-06-09Open access

Validated Filter-Based Photoreceptor Count Algorithm on Retinal Heidelberg High Magnification Module™ Images in Healthy and Pathological Conditions

Timo Mulders, Patty Dhooge, Ludo van der Zanden, Carel B. Hoyng, Thomas Theelen

Applied Sciences· Volume 11· Issue 12

Abstract

Recently introduced, the Heidelberg Engineering™ high magnification module enables in vivo visualization of cone photoreceptor cells. Currently, a reliable analysis of cone mosaic on high magnification module images is hindered by an unfavorable signal-to-noise ratio. In this paper, we describe how a novel high magnification module high-pass filter may enhance cone signals in healthy participants and patients. We compared the cone counts of our filter-based algorithm to the counts of two human graders. We found a good to excellent intragrader and intergrader correlation in both patients and healthy participants. We identified a good correlation between the average cone counts of both graders and high-pass filter cone counts in patients and healthy participants. We observed no significant difference between manual and filter-based counts via the Bland–Altman analysis. In conclusion, a quantitative cone analysis on high magnification module images is feasible manually by human graders and automatically by a filter-based algorithm. However, larger datasets are needed to improve repeatability and consistency by training human graders.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Retinal Imaging and Analysis · Retinal Diseases and Treatments · Retinal Development and Disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Ophthalmology, Donders Institute for Brain, Cognition and Behavior, Radboud University Medical Centre, 6525 EX Nijmegen, The Netherlands

Faculty of Medical Sciences, Radboud University Medical Centre, 6525 EZ Nijmegen, The Netherlands

Funding

Stichting A.F. Deutman Oogheelkunde Researchfonds · Landelijke Stichting voor Blinden en Slechtzienden · Algemene Nederlandse Vereniging ter voorkoming van Blindheid · Stichting Beheer het Schild

References (31)

Show source-provided references
1. Objective measurement of wave aberrations of the human eye with the use of a Hartmann–Shack wave-front sensor10.1364/JOSAA.11.001949 ↗
2. Adaptive optics scanning laser ophthalmoscopy10.1364/OE.10.000405 ↗
3. Adaptive optics enhanced simultaneous en-face optical coherence tomography and scanning laser ophthalmoscopy10.1364/OE.14.003345 ↗
4. LaRocca, F., Dhalla, A.-H., Kelly, M.P., Farsiu, F., and Izatt, J.A. (2013). Optimization of confocal scanning laser ophthalmoscope design. J. Biomed. Opt., 18.10.1117/1.JBO.18.7.076015 ↗
5. Retinal cone mosaic imaged with transverse scanning optical coherence tomography10.1364/OL.31.001821 ↗
6. High-speed, image-based eye tracking with a scanning laser ophthalmoscope10.1364/BOE.3.002611 ↗
7. High-Resolution In Vivo Fundus Angiography using a Nonadaptive Optics Imaging System10.1167/tvst.8.3.54 ↗
8. Bille, J.F. (2019). Compact Adaptive Optics Scanning Laser Ophthalmoscope with Phase Plates. High Resolution Imaging in Microscopy and Ophthalmoscopy, Springer.10.1007/978-3-030-16638-0 ↗
9. Spectralis High Magnification Module imaging in a case of Multiple Evanescent White Dot Syndrome10.1016/j.ajoc.2020.100727 ↗
10. Mendonça, L.S.M., Braun, P.X., Martin, S.M., Hüther, A., Mehta, N., Zhao, Y., Abu-Qamar, O., Konstantinou, E.K., Regatieri, C.V.S., and Witkin, A.J. (2020). Repeatability and Reproducibility of Photoreceptor Density Measurement in the Macula Using the Spectralis High Magnification Module. Ophthalmol. Retina.10.1016/j.oret.2020.04.021 ↗
11. Konstantinou, E.K., Mendonça, L.S.M., Braun, P., Monahan, K.M., Mehta, N., Gendelman, I., Levine, E.S., Baumal, C.R., Witkin, A.J., and Duker, J.S. (2020). Retinal Imaging using a confocal scanning laser ophthalmoscope-based high magnification module. Ophthalmol. Retina.10.1016/j.oret.2020.08.014 ↗
12. Non-adaptive Optics Cone Imaging: A comparative study with the Imagine Eyes RTX1
13. Cone photoreceptor definition on adaptive optics retinal imaging10.1136/bjophthalmol-2013-304615 ↗
14. Automatic detection of cone photoreceptors in split detector adaptive optics scanning light ophthalmoscope images10.1364/BOE.7.002036 ↗
15. Hybrid filtering and enhancement of high-resolution adaptive-optics retinal images10.1364/OL.34.003484 ↗
16. Central Areolar Choroidal Dystrophy10.1016/j.ophtha.2008.12.019 ↗
17. Optical quality of the human eye10.1113/jphysiol.1966.sp008056 ↗
18. Fiji: An open-source platform for biological-image analysis10.1038/nmeth.2019 ↗
19. Globally optimal stitching of tiled 3D microscopic image acquisitions10.1093/bioinformatics/btp184 ↗
20. Bogovic, J.A., Hanslovsky, P., Wong, A., and Saalfeld, S. (2016, January 13–16). Robust registration of calcium images by learned contrast synthesis. Proceedings of the ISBI, Prague, Czech Republic.10.1109/ISBI.2016.7493463 ↗
21. The spatial resolution capacity of human foveal retina10.1016/0042-6989(89)90058-8 ↗
22. TANGO: A generic tool for high-throughput 3D image analysis for studying nuclear organization10.1093/bioinformatics/btt276 ↗
23. In Vivo Imaging of Human Cone Photoreceptor Inner Segments10.1167/iovs.14-14542 ↗
24. Automated identification of cone photoreceptors in adaptive optics retinal images10.1364/JOSAA.24.001358 ↗
25. Performance analysis of cone detection algorithms10.1364/JOSAA.32.000497 ↗
26. Adaptive Image Contrast Enhancement by Computing Distances into a 4-Dimensional Fuzzy Unit Hypercube10.1109/ACCESS.2017.2776349 ↗
27. Fuzzy based image edge detection algorithm for blood vessel detection in retinal images10.1016/j.asoc.2020.106452 ↗
28. Methods in quantitative image analysis10.1007/BF01463655 ↗
29. Curcio, C., Sloan, S., Kalina, R.E., and Hendrickson, A.E. (1990). Human photoreceptor topography. J. Comp. Neurol.10.1002/cne.902920402 ↗
30. The organization of the cone photoreceptor mosaic measured in the living human retina10.1016/j.visres.2016.06.006 ↗
31. Adaptive Optics Retinal Imaging in CNGA3-Associated Achromatopsia: Retinal Characterization, Interocular Symmetry, and Intrafamilial Variability10.1167/iovs.18-25880 ↗