journal article·2021-01-13Open access

Effect of Wetting Conditions on the In Situ Density of Soil Using the Sand-Cone Method

Sung-Sik Park, Peter D. Ogunjinmi, Hyun-Il Lee, Seung-Wook Woo, Dong-Eun Lee

Applied Sciences· Volume 11· Issue 2

Abstract

The sand-cone method is commonly used to measure the in situ density of compacted soils. While determining field density with this method, differences in the sand-filling process between the test hole and the calibration container can cause errors. The differences can result from various in situ conditions such as the shape and size of the test hole and the moisture conditions of the filling sand and test ground. Temporary rainfall can increase the moisture content of both in situ soils and filling sand. This study examined the effect of wetting conditions on the accuracy of the sand-cone method in a laboratory. Compacted soils with different water contents (2–16%) were prepared in a small circular container in the laboratory, and the sand-filling process was simulated for cylindrical, conical, and roof-shaped test holes with depths of 10 and 15 cm. As the water content of the compacted soils increased, the sand-cone method underestimated the volume of sand accumulated in the test holes by up to 20%, resulting in the calculated density being overestimated by an identical amount. Slightly moist sand was poured into artificial test holes. When the water content of the filling sand was below 1%, no significant error was observed in the calculated volume.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Soil and Unsaturated Flow · Geotechnical Engineering and Underground Structures · Geotechnical Engineering and Soil Stabilization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil Engineering, Kyungpook National University, 80 Daehakro, Bukgu, Daegu 41566, Korea

Department of Civil Engineering, Daelim Construction Company, 14 Mirae-ro, Namdonggu, Incheon 21556, Korea

School of Architecture, Civil, Environment and Energy Engineering, Kyungpook National University, 80 Daehakro, Bukgu, Daegu 41566, Korea

Funding

National Research Foundation of Korea

References (14)

Show source-provided references
1. Steel-shot method for measuring the density of soils10.1139/T10-034 ↗
2. Evaluation of the sand-cone method for determination of the in-situ density of soil10.1680/geot.9.T.004 ↗
3. ASTM (2007). Standard Test Method for Density and Unit Weight of Soil in Place by the Sand-Cone Method. D1556-07, American Society for Testing and Materials.
4. BS 1377-9 (1990). Methods of Test for Soils for Civil Engineering Purposes. In-Situ Tests, British Standards Institution.
5. KS F 2311 (2001). Standard Test Method for Density of Soil in Place by the Sand Cone Method, Korean Industrial Standards (KS).
6. A proposal of flow limit for soils at zero undrained shear strength10.7843/kgs.2013.29.11.73 ↗
7. Development of a prototype for modelling soil–pipe interaction and its application for predicting uplift resistance to buried pipe movements in sand10.1139/cgj-2017-0559 ↗
8. Bearing capacity of rectangular footing on sandy soil bounded by a wall10.1007/s13369-014-1353-7 ↗
9. Oh, E.Y.N., Huang, M., Surarak, C., Adamec, R., and Balasurbamaniam, A.S. (2008, January 19–21). Finite element modelling for piled raft foundation in sand. Proceedings of the Eleventh East Asia-Pacific Conference on Structural Engineering & Construction (EASEC-11) “Building a Sustainable Environment”, Taipei, Taiwan.
10. ASTM (2008). Standard Test Method for Determination of Water (Moisture) Content of Soil by Microwave Oven Heating. D 4643-08, American Society for Testing and Materials.
11. A study on the measurement of moisture content in the organic soils10.7843/kgs.2013.29.10.29 ↗
12. Berney, I.V., Ernest, S., Kyzar, J.D., and Oyelami, L.O. (2011). Device Comparison for Determining Field Soil Moisture Content (No. ERDC/GSL TR-11-42), Engineer Research and Development Center.10.21236/ADA552792 ↗
13. McCook, D.K., and Shanklin, D.W. (2000). NRCS experience with field density test methods including the sand-cone, nuclear gage, rubber balloon, drive-cylinder, and clod test. Constructing and Controlling Compaction of Earth Fills, ASTM International.10.1520/STP15275S ↗
14. Kosmatka, S.H., Kerkhoff, B., and Panarese, W.C. (2002). Design and Control of Concrete Mixtures, Portland Cement Association. [14th ed.].