journal article·2021-01-06Open access

Comparative Pull-Out Performances of Cephalomedullary Nail with Screw and Helical Blade According to Femur Bone Densities

Young-Chang Park, Dong-Sik Chae, Kyung-Yil Kang, Yao Ding, Sung-Jun Park, Jonghun Yoon

Applied Sciences· Volume 11· Issue 2

Abstract

This paper mainly examines the fixation performances of the cephalomedullary nail for the incidence of intertrochanteric (IT) fracture to guide the appropriate fixations with respect to the bone density in terms of a biomechanical perspective. It is substantially important to guide which types of fixation are applied during the operation since it tends to induce the backout or migration of the helical blade and screw according to weight and bone density. Biomedical polyurethane (PUR) foam blocks for simulating human bone are adopted with two grades of densities to simulate a normal person and an elderly person who has osteoporosis. Tensile and compression tests are conducted to analyze the tensile-compression anisotropy of PUR foams. Pull-out performances of screw and helical blades are evaluated from experimental perspectives, which are supported by comparison with the results of finite element method analysis. The clamping force of the screw is higher than the helical blade, about 177% in normal foam density and 198% in low foam density. After physical evaluation of the critical pull-out fixation force of screw and helical blade, we have suggested that stable fixation is guaranteed when the pull-out force is larger than projected force.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Hip and Femur Fractures · Spinal Fractures and Fixation Techniques · Pelvic and Acetabular Injuries

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthopedic Surgery, International St. Mary’s Hospital, College of Medicine, Catholic Kwandong University, Incheon 22711, Korea

Department of Medicine, Catholic Kwandong Graduate School, Gangneung-si, Gangwon-do 25601, Korea

BK21 FOUR ERICA-ACE Center, Department of Mechanical Engineering, Hanyang University, 55 Hanyangdaehak-ro, Sangnok-gu, Ansan, Gyeonggi-do 15588, Korea

Department of Mechanical Engineering, Korea National University of Transportation, 50 Daehak-ro, Chungju, Chungcheongbuk-do 27469, Korea

Funding

National Research Foundation of Korea · Korea Institute of Energy Technology Evaluation and Planning (KETEP)

References (36)

Show source-provided references
1. The treatment of unstable, extracapsular hip fractures with the AO/ASIF proximal femoral nail (PFN)—Our first 60 cases10.1016/S0020-1383(02)00054-2 ↗
2. Surgical treatment of basicervical intertrochanteric fractures of the proximal femur with cephalomeduallary hip nails10.1111/os.12038 ↗
3. Outcome Afer Surgery for the Treatment of Hip Fracture in the Extremely Elderly10.2106/JBJS.G.00883 ↗
4. Basicervical fracture-A rare type of hip fracture10.1007/s004020100306 ↗
5. A different treatment modality fortrochanteric fractures of the femur in surgical high-risk patients: A clinical studyof 44 patients with 21-month follow-up10.1007/s00402-003-0578-9 ↗
6. Mortality, disability, and nursing home use for persons with and without hip fracture: A population-based study10.1046/j.1532-5415.2002.50455.x ↗
7. The 1-Year Mortality of Patients Treated in a Hip Fracture Program for Elders10.1177/2151458510378105 ↗
8. Intramedullary versus extramedullary internal fixation for unstable intertrochanteric fracture, a meta-analysis10.1016/j.aott.2018.02.009 ↗
9. Operative management of lower extremity fractures in patients with head injuries10.1097/00003086-200302000-00027 ↗
10. Conversion of external fixation to intramedullary nailing for fractures of the shaft of the femur in multiply injured patients10.2106/00004623-200006000-00004 ↗
11. Intramedullary fixation of unstable intertrochanteric hip fractures: One or two lag screws10.1097/00005131-200401000-00003 ↗
12. The effect of local bone mineral density on the rate of mechanical failure after surgical treatment of distal radius fractures: A prospective multicentre cohort study including 249 patients10.1007/s00402-015-2211-0 ↗
13. Locking plate fixation versus antegrade nailing of 3-and 4-part proximal humerus fractures in patients without osteoporosis. Comparative retrospective study of 63 cases10.1016/j.otsr.2014.09.021 ↗
14. Prospective randomized study comparing two cephalomedullary nails for elderly intertrochanteric fractures: Zimmer natural nail versus proximal femoral nail antirotation II10.1016/j.injury.2017.04.011 ↗
15. Treatment with helical blade Cephalomedullary nail for two-part Basicervical proximal femoral fracture in elderly patients: A retrospective observational study10.1177/2151458517743327 ↗
16. Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: A biomechanical evaluation10.1016/j.injury.2006.06.008 ↗
17. Fixation of subtrochanteric fractures: Does a technical optimization of the dynamic hip screw application improve the results?10.1007/s11751-009-0058-z ↗
18. Subtrochanteric femur fracture10.1097/00005131-200204000-00012 ↗
19. Treatment of subtrochanteric fractures of the femur: Reduction on the traction table and fixation with dynamic condylar screw10.1007/BF00441620 ↗
20. A retrospective analysis of the InterTan nail and proximal femoral nail anti-rotation-Asia in the treatment of unstable intertrochanteric femur fractures in the elderly10.1186/s13018-016-0344-7 ↗
21. Complete traumatic backout of the blade of proximal femoral nail antirotation: A case report10.1016/j.otsr.2013.12.028 ↗
22. Proximal femoral nail anti-rotation (PFNA) to treat peritrochanteric fractures in elderly patients10.1007/s00590-011-0810-1 ↗
23. Hip screw lateral migration with no cut-out or non-union implication: A case report10.1186/1757-1626-2-6419 ↗
24. Biomechanical comparison between standard and inclined screw orientation in dynamic hip screw side-plate fixation: The lift-off phenomenon
25. Lee, E.S., Goh, T.S., Heo, J.Y., Kim, Y.J., Lee, S.E., Kim, Y.H., and Lee, C.S. (2019). Experimental Evaluation of Screw Pullout Force and Adjacent Bone Damage According to Pedicle Screw Design Parameters in Normal and Osteoporotic Bones. Appl. Sci., 9.10.3390/app9030586 ↗
26. Pullout performance of self-tapping medical screws10.1115/1.4005172 ↗
27. 3D digital image correlation methods for full-field vibration measurement10.1016/j.ymssp.2010.08.013 ↗
28. Investigation for plastic damage constitutive models of the concrete material10.1016/j.proeng.2017.11.050 ↗
29. Concrete plastic-damage factor for finite element analysis: Concept, simulation, and experiment10.1177/1687814017719642 ↗
30. Finite Element Model of RC Columns Subjected to Projectile Impact with Different Velocities10.18178/ijscer.7.1.8-14 ↗
31. A plastic-damage model for concrete10.1016/0020-7683(89)90050-4 ↗
32. Cracking development prediction in concrete gravity dams using concrete damaged plasticity model
33. Plastic-damage model for cyclic loading of concrete structures10.1061/(ASCE)0733-9399(1998)124:8(892) ↗
34. Birtel, V., and Mark, P. (2006, January 23–25). Parameterised finite element modelling of RC beam shear failure. Proceedings of the 2006 ABAQUS Users’ Conference, Boston, MA, USA.
35. Bergmann, G., Bender, A., Dymke, J., Duda, G., and Damm, P. (2016). Standardized loads acting in hip implants. PLoS ONE, 15.10.1371/journal.pone.0155612 ↗
36. Schaeffer, E.K., and Mulpuri, K. (2019). Anatomy and Physiology of the Pediatric Hip. Pediatric Adolesc. Hip., 29–51.10.1007/978-3-030-12003-0_2 ↗