journal article·2020-09-09Open access

Coregistration and Spatial Compounding of Optoacoustic Cardiac Images via Fourier Analysis of Four-Dimensional Data

Hongtong Li, Ivana Ivankovic, Jiao Li, Daniel Razansky, Xosé Luís Deán-Ben

Applied Sciences· Volume 10· Issue 18

Abstract

Volumetric optoacoustic tomography has been shown to provide unprecedented capabilities for ultrafast imaging of cardiovascular dynamics in mice. Three-dimensional imaging rates in the order of 100 Hz have been achieved, which enabled the visualization of transient cardiac events such as arrhythmias or contrast agent perfusion without the need for retrospective gating. The fast murine heart rates (400–600 beats per minute) yet impose limitations when it comes to compounding of multiple frames or accurate registration of multi-spectral data. Herein, we investigate on the capabilities of Fourier analysis of four-dimensional data for coregistration of independent volumetric optoacoustic image sequences of the heart. The fundamental frequencies and higher harmonics of respiratory and cardiac cycles could clearly be distinguished, which facilitated efficient retrospective gating without additional readings. The performance of the suggested methodology was successfully demonstrated by compounding cardiac images acquired by raster-scanning of a spherical transducer array as well as by unmixing of oxygenated and deoxygenated hemoglobin from multi-spectral optoacoustic data.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Photoacoustic and Ultrasonic Imaging · Optical Imaging and Spectroscopy Techniques · Optical Coherence Tomography Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology University of Zürich and ETH Zürich, 8057 Zürich, Switzerland

School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China

Funding

Helmut Horten Stiftung

References (39)

Show source-provided references
1. Myocardial infarction and cardiac remodelling in mice10.1113/eph8702385 ↗
2. Mouse models of cardiac arrhythmias10.1161/CIRCRESAHA.118.313406 ↗
3. Multispectral optoacoustic tomography of myocardial infarction10.1016/j.pacs.2012.11.001 ↗
4. Cardiovascular imaging in mice10.1002/9780470942390.mo150122 ↗
5. Comparison between prospective and retrospective triggering for mouse cardiac MRI
6. Micro-CT with respiratory and cardiac gating: Micro-CT with respiratory and cardiac gating10.1118/1.1812604 ↗
7. Accelerated cardiovascular magnetic resonance of the mouse heart using self-gated parallel imaging strategies does not compromise accuracy of structural and functional measures10.1186/1532-429X-12-43 ↗
8. Simultaneous positron emission tomography and ultrafast ultrasound for hybrid molecular, anatomical and functional imaging10.1038/s41551-018-0188-z ↗
9. Vinegoni, C., Aguirre, A.D., Lee, S., and Weissleder, R. (2015). Imaging the beating heart in the mouse using intravital microscopy techniques. Nat. Protoc., 10.10.1038/nprot.2015.119 ↗
10. Deán-Ben, X.L., Ford, S.J., and Razansky, D. (2015). High-frame rate four dimensional optoacoustic tomography enables visualization of cardiovascular dynamics and mouse heart perfusion. Sci. Rep., 5.10.1038/srep10133 ↗
11. Advances in real-time multispectral optoacoustic imaging and its applications10.1038/nphoton.2015.29 ↗
12. Single-impulse panoramic photoacoustic computed tomography of small-animal whole-body dynamics at high spatiotemporal resolution10.1038/s41551-017-0071 ↗
13. Transmission–reflection optoacoustic ultrasound (TROPUS) computed tomography of small animals
14. Ultrafast volumetric optoacoustic imaging of whole isolated beating mouse heart
15. Volumetric optoacoustic tomography enables non-invasive in vivo characterization of impaired heart function in hypoxic conditions10.1038/s41598-019-44818-8 ↗
16. Lin, H.-C.A., Déan-Ben, X.L., Ivankovic, I., Kimm, M.A., Kosanke, K., Haas, H., Meier, R., Lohöfer, F., Wildgruber, M., and Razansky, D. (2017). Characterization of cardiac dynamics in an acute myocardial infarction model by four-dimensional optoacoustic and magnetic resonance imaging. Theranostics, 7.10.7150/thno.20616 ↗
17. Ivankovic, I., Déan-Ben, X.L., Haas, H., Kimm, M.A., Wildgruber, M., and Razansky, D. (2020). Volumetric Optoacoustic Tomography Differentiates Myocardial Remodelling. Mol. Imaging Biol.10.1007/s11307-020-01498-5 ↗
18. Optoacoustic micro-tomography at 100 volumes per second
19. Portable spherical array probe for volumetric real-time optoacoustic imaging at centimeter-scale depths10.1364/OE.21.028062 ↗
20. Deán-Ben, X.L., Fehm, T.F., Ford, S.J., Gottschalk, S., and Razansky, D. (2017). Spiral volumetric optoacoustic tomography visualizes multi-scale dynamics in mice. Light Sci. Appl., 6.10.1038/lsa.2016.247 ↗
21. In vivo whole-body optoacoustic scanner with real-time volumetric imaging capacity10.1364/OPTICA.3.001153 ↗
22. Ozbek, A., Deán-Ben, X., and Razansky, D. Realtime parallel back-projection algorithm for three-dimensional optoacoustic imaging devices. Proceedings of the European Conference on Biomedical Optics; Optical Society of America, Washington, DC, USA.
23. Spatial Compounding of Volumetric Data Enables Freehand Optoacoustic Angiography of Large-Scale Vascular Networks10.1109/TMI.2019.2945297 ↗
24. Cox, B.T., Laufer, J.G., Beard, P.C., and Arridge, S.R. (2012). Quantitative spectroscopic photoacoustic imaging: A review. J. Biomed. Opt., 17.10.1117/1.JBO.17.6.061202 ↗
25. Measurement of right atrial oxygen saturation by fiberoptic oximetry accurately reflects mixed venous oxygen saturation in swine10.1007/BF01641809 ↗
26. A comparison of central and mixed venous oxygen saturation in circulatory failure10.1053/j.jvca.2007.10.011 ↗
27. Lin, L., Yao, J., Li, L., and Wang, L.V. (2015). In vivo photoacoustic tomography of myoglobin oxygen saturation. J. Biomed. Opt., 21.10.1117/1.JBO.21.6.061002 ↗
28. Özbek, A., Deán-Ben, X.L., and Razansky, D. (2020). Compressed Optoacoustic Sensing of Volumetric Cardiac Motion. IEEE Trans. Med. Imaging.10.1109/TMI.2020.2985134 ↗
29. Tomaszewski, M.R., Gonzalez, I.Q., O’Connor, J.P., Abeyakoon, O., Parker, G.J., Williams, K.J., Gilbert, F.J., and Bohndiek, S.E. (2017). Oxygen enhanced optoacoustic tomography (OE-OT) reveals vascular dynamics in murine models of prostate cancer. Theranostics, 7.10.7150/thno.19841 ↗
30. Volumetric optoacoustic imaging unveils high-resolution patterns of acute and cyclic hypoxia in a murine model of breast cancer10.1158/0008-5472.CAN-18-3769 ↗
31. High frame rate photoacoustic imaging at 7000 frames per second using clinical ultrasound system10.1364/BOE.7.000312 ↗
32. Optoacoustic imaging at kilohertz volumetric frame rates10.1364/OPTICA.5.000857 ↗
33. Cardiovascular optoacoustics: From mice to men—A review10.1016/j.pacs.2019.03.001 ↗
34. Detection of collagens by multispectral optoacoustic tomography as an imaging biomarker for Duchenne muscular dystrophy10.1038/s41591-019-0669-y ↗
35. Real-time volumetric assessment of the human carotid artery: Handheld multispectral optoacoustic tomography10.1148/radiol.2019181325 ↗
36. Xia, J., Chen, W., Maslov, K.I., Anastasio, M.A., and Wang, L.V. (2014). Retrospective respiration-gated whole-body photoacoustic computed tomography of mice. J. Biomed. Opt., 19.10.1117/1.JBO.19.1.016003 ↗
37. Ron, A., Davoudi, N., Deán-Ben, X.L., and Razansky, D. (2019). Self-gated respiratory motion rejection for optoacoustic tomography. Appl. Sci., 9.10.3390/app9132737 ↗
38. Listening to the brain with photoacoustics10.1109/JSTQE.2015.2487890 ↗
39. Rapid volumetric optoacoustic imaging of neural dynamics across the mouse brain10.1038/s41551-019-0372-9 ↗