EVAR-eaSE: An Easy-to-Use Software for Planning Sac Embolization in EndoVascular Aneurysm Repair Procedure
Source abstract
Abstract
Background: Endovascular aneurysm repair (EVAR) has become the primary choice of treatment for abdominal aortic aneurysm (AAA) and preventive intraoperative AAA sac embolization (SE) is an effective way to reduce endoleaks after EVAR. Preoperative planning of AAA SE has not been standardized yet, and typically requires a quite long and operator-dependent procedure using standard EVAR planning software. Methods: We introduce ‘EVAR-eaSE’, a software tool that we have developed to help vascular surgeons to plan the optimal SE procedure during EVAR, providing semi-automatic AAA segmentation and 3D modeling starting from patient scans, and then computing the aneurysm volumes. A preliminary accuracy evaluation on radiological phantoms, and a comparison with the commercial 3Mensio software for EVAR planning are carried out. Results: EVAR-eaSE software showed a good level of accuracy in aneurysm volume reconstruction and calculation (mean difference of 2.5% between real and segmented phantom volumes). A strong positive correlation (r = 0.940, r = 0.954, p < 0.001) was found between EVAR-eaSE computation of AAA Lumen and AAA Total volumes and the same measurements obtained with 3Mensio, for a database of 26 AAA cases. Conclusions: EVAR-eaSE demonstrated to be an easy-to-use, objective and accurate tool to assist the vascular surgeons in preoperative planning of SE during EVAR.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Aortic aneurysm repair treatments · Advanced X-ray and CT Imaging · Renal and Vascular Pathologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
eDIMES Lab—Laboratory of Bioengineering, Department of Experimental Diagnostic and Specialty Medicine (DIMES), University of Bologna, 40138 Bologna, Italy
Vascular Surgery, Department of Experimental Diagnostic and Specialty Medicine (DIMES), University of Bologna, 40138 Bologna, Italy
References (25)
Show source-provided references
1. Endovascular versus open repair of abdominal aortic aneurysm in 15-years’ follow-up of the UK endovascular aneurysm repair trial 1 (EVAR trial 1): A randomised controlled trail10.1016/j.jvs.2016.12.059 ↗
2. The influence of study design on the evaluation of ruptured abdominal aortic aneurysm treatment10.1016/j.avsg.2014.03.017 ↗
3. Persistent type 2 endoleak after endovascular repair of abdominal aortic aneurysm is associated with adverse late outcomes10.1016/j.jvs.2007.02.073 ↗
4. Preoperative variables predict persistent type 2 endoleak after endovascular aneurysm repair10.1016/j.jvs.2010.02.023 ↗
5. Vascular Study Group of New England Risk factors and consequences of persistent type II endoleaks10.1016/j.jvs.2015.10.088 ↗
6. Outcomes of endovascular aneurysm repair with contemporary volume-dependent sac embolization in patients at risk for type II endoleak10.1016/j.jvs.2015.08.049 ↗
7. Type II endoleak prevention with coil embolization during endovascular aneurysm repair in high-risk patients10.1016/j.jvs.2015.02.030 ↗
8. Pre-emptive nonselective perigraft aortic sac embolization with coils to prevent type II endoleak after endovascular aneurysm repair10.1016/j.jvs.2018.10.054 ↗
9. Selective Intra-procedural AAA sac Embolization During EVAR Reduces the Rate of Type II Endoleak10.1016/j.ejvs.2015.12.009 ↗
10. Analysis of anatomical risk factors for persistent type II endoleaks following endovascular abdominal aortic aneurysm repair using CT angiography10.1007/s00595-015-1115-5 ↗
11. Persistent type II endoleak after EVAR: The predictive value of the AAA thrombus volume
12. Evaluation and coil embolization of the aortic side branches for prevention of type ii endoleak after endovascular repair of abdominal aortic aneurysm10.3400/avd.oa.17-00088 ↗
13. IP071. Persistent type ii endoleak prevention by abdominal aortic aneurysm sac embolization during EVAR: An analysis of aneurysm volume and coils concentration10.1016/j.jvs.2017.03.139 ↗
14. Semiautomatic sizing software in emergency endovascular aneurysm repair for ruptured abdominal aortic aneurysms
15. Validation of a new standardized method to measure proximal aneurysm neck angulation10.1016/j.jvs.2009.10.114 ↗
16. Comparative analysis of aneurysm volume by different methods based on angiography and computed tomography angiography10.1007/s10143-018-0943-3 ↗
17. AngioSuite: An accurate method to calculate aneurysm volumes and packing densities10.1136/neurintsurg-2012-010317 ↗
18. Active contours without edges10.1109/83.902291 ↗
19. Computational methods for the image segmentation of pigmented skin lesions: A review10.1016/j.cmpb.2016.03.032 ↗
20. Volume measurement of intracranial aneurysms from 3D rotational angiography: Improvement of accuracy by gradient edge detection
21. Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms
22. Relation between Aneurysm Volume, Packing, and Compaction in 145 Cerebral Aneurysms Treated with Coils10.1148/radiol.2313030460 ↗
23. Comparison of cerebral aneurysm volumes as determined by digitally measured 3D rotational angiography and approximation from three diameters10.1177/159101991101700203 ↗
24. An inverse approach for automatic segmentation of carotid and vertebral arteries in CTA10.1016/j.eswa.2017.10.041 ↗
25. Blood vessel segmentation algorithms—Review of methods, datasets and evaluation metrics10.1016/j.cmpb.2018.02.001 ↗