Effect of Aging under AC Superimposed Harmonic Voltage on Trap and Carrier Transport Properties of Silicone Rubber
Source abstract
Abstract
The rapid growth of power grid capacity and the widespread use of a large number of power electronics and non-linear loads have led to harmonics in the power system. Harmonics in the power system will cause safety hazards to the normal operation of power equipment, exacerbate the aging of insulation materials, and reducing the overall operation reliability of the system. In the present work, we used power frequency ac voltage superimposed harmonics to carry out ageing experiments on power cable terminals. Then, we tested the infrared spectra, dielectric spectra, electrical conductivity, and surface potential decay characteristics of silicone rubber insulation materials on the cable terminals aged for different times. The experimental results show that the dielectric constant and dielectric loss of silicone rubber gradually increase with the aging time. In particular, the dielectric loss of silicone rubber changed greatly at low frequencies. The effect of dc conductance of aged silicone rubber on dielectric loss is significantly enhanced at low frequencies, which causes the dielectric loss to increase as the frequency decreases following an inverse power law. The surface potential decay rates of silicone rubber insulation after positive and negative corona charging accelerate with increasing the aging time, which is consistent with the experimental results of electrical conductivity. By analyzing the distribution characteristics of electron and hole traps in silicone rubbers, it is found that the trap energy levels of electron and hole traps become shallower as the operating time increases. The calculation of the carrier hopping conduction model shows that the shallow trap formed with increasing the aging time will lead to increases in both carrier mobility and conductivity. When the conductivity rises to a certain value, the silicone rubber will lose its insulation performance, resulting in insulation failure.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: High voltage insulation and dielectric phenomena · Power Transformer Diagnostics and Insulation · Lightning and Electromagnetic Phenomena
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi’an 710024, China
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, Shaanxi, China
Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China
Funding
State Key Laboratory of Intense Pulsed Radiation Simulation and Effect · State Grid Corporation of China Science Project
References (24)
Show source-provided references
1. Research and application of uhv power transmission in china10.1049/hve.2018.0003 ↗
2. Martinez-Velasco, J.A. (2010). Power System Transients: Parameter Determination, CRC Press.
3. Power cable technology review
4. Thermo characteristics of silicone rubber and its effects on operational reliability of extra-high voltage cable accessories
5. Dealing with interface problems in polymer cable terminations10.1109/57.776938 ↗
6. Degradation mechanisms of silicone rubber (sir) by accelerated ageing for cables of nuclear power plant10.1109/TDEI.2013.004177 ↗
7. Electrical and material characterization of field-aged 400 kV silicone rubber composite insulators10.1109/TDEI.2010.5448091 ↗
8. Min, D.M., Yan, C.Y., Huang, Y., Li, S.T., and Ohki, Y. (2017). Dielectric and carrier transport properties of silicone rubber degraded by gamma irradiation. Polymers, 9.10.3390/polym9100533 ↗
9. Polymeric insulation materials for hvdc cables: Development, challenges and future perspective10.1109/TDEI.2017.006205 ↗
10. Verdu, J. (2012). Oxidative Ageing of Polymers, John Wiley & Sons.10.1002/9781118562598 ↗
11. Molecular chain motion and electrode polarization properties of silicone rubber
12. The influence of irradiation temperature and oxygen on crosslink formation and segment mobility in gamma-irradiated polydimethylsiloxanes
13. Space charge analysis and trap evaluation in silicone rubber by density functional study
14. Characterizing space charge transportation in hv xlpe cable insulation based on surface potential decay measurement
15. Surface and volume charge transport properties of polyimide revealed by surface potential decay with genetic algorithm10.1109/TDEI.2012.6260024 ↗
16. The energy distribution of trapped charges in polymers based on isothermal surface potential decay model10.1109/TDEI.2015.7116370 ↗
17. Theory of isothermal currents and the direct determination of trap parameters in semiconductors and insulators containing arbitrary trap distributions10.1103/PhysRevB.7.3706 ↗
18. Dissado, L.A., and Fothergill, J.C. (1992). Electrical Degradation and Breakdown in Polymers, Peter Peregrinus Ltd.10.1049/PBED009E ↗
19. Charge transport modeling in insulating polymers: From molecular to macroscopic scale10.1109/TDEI.2005.1522182 ↗
20. Hanada, S., Odaka, D., Yang, L.Q., Hirai, N., and Ohki, Y. (2016, January 25–28). Non-destructive diagnosis of degradation of silicone rubber by indenter modulus and scanning probe microscopy. Proceedings of the International Conference on Condition Monitoring and Diagnosis (CMD), Xi’an, China.10.1109/CMD.2016.7757791 ↗
21. Kao, K.C. (2004). Dielectric Phenomena in Solids, Elsevier.
22. Electrical aging and life models: The role of space charge10.1109/TDEI.2005.1522183 ↗
23. Ohki, Y., Hanada, S., Miyamoto, M., Hirai, N., and Yang, L.Q. (2016, January 16–19). Aging mechanism of silicone rubber by heat and gamma-rays. Proceedings of the IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Toronto, ON, Canada.10.1109/CEIDP.2016.7785487 ↗
24. Review of high voltage direct current cables10.17775/CSEEJPES.2015.00015 ↗