journal article·2016-01-20Open access

A Liquid-Solid Coupling Hemodynamic Model with Microcirculation Load

Bai Li, Xiaoyang Li

Applied Sciences· Volume 6· Issue 1

Abstract

From the aspect of human circulation system structure, a complete hemodynamic model requires consideration of the influence of microcirculation load effect. This paper selected the seepage in porous media as the simulant of microcirculation load. On the basis of a bi-directional liquid-solid coupling tube model, we built a liquid-solid-porous media seepage coupling model. The simulation parameters accorded with the physiological reality. Inlet condition was set as transient single-pulse velocity, and outlet as free outlet. The pressure in the tube was kept at the state of dynamic stability in the range of 80–120 mmHg. The model was able to simulate the entire propagating process of pulse wave. The pulse wave velocity simulated was 6.25 m/s, which accorded with the physiological reality. The complex pressure wave shape produced by reflections of pressure wave was also observed. After the model changed the cardiac cycle length, the pressure change according with actual human physiology was simulated successfully. The model in this paper is well-developed and reliable. It demonstrates the importance of microcirculation load in hemodynamic model. Moreover the properties of the model provide a possibility for the simulation of dynamic adjustment process of human circulation system, which indicates a promising prospect in clinical application.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Mechanical Circulatory Support Devices · Coronary Interventions and Diagnostics · Hemodynamic Monitoring and Therapy

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Biomechanical Research Laboratory, Center of Engineering Mechanics, Beijing University of Technology, No.100 Pingleyuan, Chaoyang District, Beijing 100124, China

References (20)

Show source-provided references
1. Numerical implementation of viscoelastic blood flow in a simplified arterial geometry10.1016/j.medengphy.2006.07.002 ↗
2. Role of the bloodstream impacting force and the local pressure elevation in the rupture of cerebral aneurysms10.1161/01.STR.0000177877.88925.06 ↗
3. Modeling of flow in a straight stented and nonstented side wall aneurysm model10.1115/1.2796081 ↗
4. Hemodynamics of human carotid artery bifurcations: Computational studies with models reconstructed from magnetic resonance imaging of normal subjects10.1016/S0741-5214(98)70210-1 ↗
5. Molony, D.S., Callanan, A., Kavanagh, E.G., Walsh, M.T., and McGloughlin, T.M. (2009). Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft. Biomed. Eng. Online, 8.10.1186/1475-925X-8-24 ↗
6. Wang, X.H., and Li, X.Y. (2012). The influence of wall compliance on flow pattern in a curved artery exposed to a dynamic physiological environment: An elastic wall model versus a rigid wall model. J. Mech. Med. Biol., 12.10.1142/S0219519412005095 ↗
7. Biomechanical behaviour of cerebral aneurysm and its relation with the formation of intraluminal thrombus: A patient-specific modelling study10.1080/10255842.2011.652098 ↗
8. A Computational Fluid Dynamic (CFD) Tool for Optimization and Guided Implantation of Biomedical Devices10.1115/1.3147516 ↗
9. Nichols, W., O’Rourke, M., and Vlachopoulos, C. (2011). McDonald’s Blood Flow in Arteries, Hodder Arnold.
10. Wang, X., and Li, X. (2012). Computer-based mechanical analysis of stenosed artery with thrombotic plaque: The influences of important physiological parameters. J. Mech. Med. Biol., 12.10.1142/S0219519412500698 ↗
11. Functional characteristics of myocardial bridging—A combined angiographic and intracoronary Doppler flow study10.1093/oxfordjournals.eurheartj.a015263 ↗
12. Hemodynamics analysis of patient-specific carotid bifurcation: A CFD model of downstream peripheral vascular impedance10.1002/cnm.2529 ↗
13. Fung, Y.C. (2005). Biomechanics, Mechanical Properties of Living Tissues, Springer.
14. Geometrical enhancements for abdominal aortic stent-grafts10.1583/08-2388.1 ↗
15. The rheology of large blood vessels
16. Fluid-structure interaction within realistic three-dimensional models of the aneurysmatic aorta as a guidance to assess the risk of rupture of the aneurysm10.1016/S1350-4533(01)00093-5 ↗
17. A computational study on the biomechanical factors related to stent-graft models in the thoracic aorta10.1007/s11517-008-0361-8 ↗
18. Aortic blood pressure and velocity as a function of time and position10.1152/jappl.1968.24.4.563 ↗
19. Asmar, R., O’Rourke, M., and Safar, M. (1999). Arterial Stiffness and Pulse Wave Velocity: Clinical Applications, Elsevier.
20. The Croonian Lecture: On the Functions of the Heart and Arteries