journal article·2023-07-12Open access

T-Scan Novus System Application—Digital Occlusion Analysis of 3D Printed Orthodontics Retainers

Dobromira Shopova, Antoniya Yaneva, Desislava Bakova, Anna Mihaylova, Miroslava Yordanova, Svetlana Yordanova

Applied Sciences· Volume 13· Issue 14

Abstract

(1) Background: This study aims to evaluate the occlusal force distribution across different quadrants during the placement of orthodontic retainers fabricated using a biocompatible material via digital design. (2) Materials and Methods: A cohort of 21 patients in the retention phase following orthodontic treatment was included in this study. Intraoral scans were obtained using Trios color (3Shape). For retainer fabrication, the splint studio module of the 3Shape design software was utilized. Occlusal evaluation was performed using T-Scan Novus (Tekscan). The Kolmogorov–Smirnov test, Wilcoxon signed ranks test, and Mann–Whitney U test were used for statistical analysis. (3) Results: The digital design set evenly distributed contacts on all occluding surfaces. These contacts, uniform in area, turned out to be uneven in pressure: right distal—37.14%, right frontal—11.4%, left frontal—11.46%, and left distal—39.99%. (4) Conclusions: The results of the study indicate that the digital design workflow has the capability to achieve uniform contact distribution by area. However, despite the achievement of uniform contact distribution, the study found that there was an unequal distribution of occlusal forces. Specifically, the distal sections of the teeth experienced significantly higher loading compared to the frontal sections.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Orthodontics and Dentofacial Orthopedics · Temporomandibular Joint Disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University, 4002 Plovdiv, Bulgaria

Department of Medical Informatics, Biostatistics and eLearning, Faculty of Public Health, Medical University, 4002 Plovdiv, Bulgaria

Department of Health Care Management, Faculty of Public Health, Medical University, 4002 Plovdiv, Bulgaria

Medical College, Medical University, 4002 Plovdiv, Bulgaria

Department of Orthodontics, Faculty of Dental Medicine, Medical University, 4002 Plovdiv, Bulgaria

Funding

Medical University—Plovdiv, Bulgaria

References (40)

Show source-provided references
1. Retention in Orthodontics10.1038/sj.bdj.2015.47 ↗
2. Orthodontic retention protocols: An evidence-based overview10.1038/s41415-021-2954-7 ↗
3. Contemporary approaches to orthodontic retention10.1111/j.1708-8240.2012.00509.x ↗
4. Lyros, I., Tsolakis, I.A., Maroulakos, M.P., Fora, E., Lykogeorgos, T., Dalampira, M., and Tsolakis, A.I. (2023). Orthodontic Retainers—A Critical Review. Children, 10.10.3390/children10020230 ↗
5. Orthodontic retention procedures in Switzerland
6. Accuracy of orthodontic 3D printed retainers versus thermoformed retainers10.4236/ojmi.2017.74017 ↗
7. The digital impression as an initial unit of modern dental medicine—Literature review
8. Current status and applications of 3D scanning in dentistry10.1016/j.cegh.2018.07.005 ↗
9. Customized procedure to display T-Scan occlusal contacts10.1016/j.prosdent.2016.07.006 ↗
10. T-Scan a digital pathway to occlusal perfection: A review
11. Kerstein, R.B. (2020). Handbook of Research on Clinical Applications of Computerized Occlusal Analysis in Dental Medicine, IGI Global.10.4018/978-1-5225-9254-9 ↗
12. Anselmi, R., and Kerstein, R.B. (2020). Handbook of Research on Clinical Applications of Computerized Occlusal Analysis in Dental Medicine, IGI Global.10.4018/978-1-5225-9254-9 ↗
13. An evaluation of occlusal contact marking indicators: A descriptive quantitative method10.14219/jada.archive.2001.0373 ↗
14. T-scan: Occlusion demystified
15. Clinician accuracy when subjectively interpreting articulating paper markings10.1179/0886963413Z.0000000001 ↗
16. Reliability, validity, and utility of various occlusal measurement methods and techniques10.1016/S0022-3913(00)70092-8 ↗
17. Phenomenon of domination of the strongest contacts in centric occlusion
18. (2023, July 05). Available online: https://nextdent.com/products/ortho-clear/.
19. T-Scan Novus System in the Management of Splints—Pilot Study
20. Firlej, M., Zaborowicz, K., Zaborowicz, M., Firlej, E., Domagała, I., Pieniak, D., Igielska-Kalwat, J., Dmowski, A., and Biedziak, B. (2022). Mechanical Properties of 3D Printed Orthodontic Retainers. Int. J. Environ. Res. Public Health, 19.10.3390/ijerph19095775 ↗
21. Evaluation of fit for 3D-printed retainers compared with thermoform retainers10.1016/j.ajodo.2018.09.011 ↗
22. Sangalli, L., Savoldi, F., Dalessandri, D., Bonetti, S., Gu, M., Signoroni, A., and Paganelli, C. (2021). Effects of remote digital monitoring on oral hygiene of orthodontic patients: A prospective study. BMC Oral Health, 21.10.1186/s12903-021-01793-9 ↗
23. Remote digital monitoring during the retention phase of orthodontic treatment: A prospective feasibility study10.4041/kjod.2022.52.2.123 ↗
24. Sangalli, L., Alessandri-Bonetti, A., and Dalessandri, D. (2023). Effectiveness of dental monitoring system in orthodontics: A systematic review. J. Orthod., 14653125231178040.10.1177/14653125231178040 ↗
25. Paradowska-Stolarz, A., Wieckiewicz, M., Kozakiewicz, M., and Jurczyszyn, K. (2023). Mechanical Properties, Fractal Dimension, and texture analysis of selected 3D-Printed resins used in Dentistry that underwent the Compression Test. Polymers, 15.10.3390/polym15071772 ↗
26. Paradowska-Stolarz, A., Malysa, A., and Mikulewicz, M. (2022). Comparison of the Compression and Tensile Modulus of Two Chosen Resins Used in Dentistry for 3D Printing. Materials, 15.10.3390/ma15248956 ↗
27. Evaluation of the mechanical properties and degree of conversion of 3D printed splint material10.1016/j.jmbbm.2020.104254 ↗
28. Comparison of hardness and polishability of various occlusal splint materials10.1016/j.jmbbm.2020.104270 ↗
29. Effects of thermoplastic retainers on occlusal contacts10.1093/ejo/cjp062 ↗
30. Kim, K.Y., Choi, J.Y., Oh, S.H., Moon, H.W., Kim, S.H., Ahn, H.W., Kim, K.A., and Nelson, G. (2021). Computerized Assessment of Occlusion and Muscle Activity during Use of a Multilayer Clear Retainer: A Preliminary Study. Sensors, 21.10.3390/s21020541 ↗
31. Occlusal contact changes with removable and bonded retainers in a 1-year retention period10.2319/101608-536.1 ↗
32. Hiemenz, J. (2011). 3D Printing with FDM: How It Works, Stratasys Inc.
33. Photo-curing 3D printing technique and its challenges10.1016/j.bioactmat.2019.12.003 ↗
34. Park, H.R., Park, J.M., Chun, Y.S., Lee, K.N., and Kim, M. (2015). Changes in views on digital intraoral scanners among dental hygienists after training in digital impression taking. BMC Oral. Health, 15.10.1186/s12903-015-0140-5 ↗
35. Accuracy of intraoral scans in the mixed dentition: A prospective non-randomized comparative clinical trial10.1186/s13005-020-00222-6 ↗
36. Christopoulou, I., Kaklamanos, E.G., Makrygiannakis, M.A., Bitsanis, I., Perlea, P., and Tsolakis, A.I. (2022). Intraoral scanners in Orthodontics: A critical review. Int. J. Environ. Res. Public Health, 19.10.3390/ijerph19031407 ↗
37. Force levels of fiber-reinforced composites and orthodontic stainless-steel wires: A 3-point bending test10.1016/j.ajodo.2006.01.047 ↗
38. Accelerated Fatigue Resistance of Bonded Composite Resin and Lithium Disilicate Screw-Retained Incisor Crowns with Long and Short Titanium Bases10.11607/prd.5736 ↗
39. Surface roughness of flowable resin composites eroded by acidic and alcoholic drinks10.4103/0972-0707.94581 ↗
40. Wear and Color Stability of Preheated Bulk-fill and Conventional Resin Composites10.2341/21-077-L ↗