journal article·2021-12-24Open access

Post-Test Numerical Analysis of a Helium-Cooled Breeding Blanket First Wall under LOFA Conditions with the MELCOR Fusion Code

Michela Angelucci, Bruno Gonfiotti, Bradut-Eugen Ghidersa, Xue Zhou Jin, Mihaela Ionescu-Bujor, Sandro Paci, Robert Stieglitz

Applied Sciences· Volume 12· Issue 1

Abstract

The validation of numerical tools employed in the analysis of incidental transients in a fusion reactor is a topic of main concern. KIT is taking part in this task providing both experimental data and by performing numerical analysis in support of the main codes used for the safety analyses of the Helium Cooled Pebble Bed (HCPB) blanket concept. In recent years, an experimental campaign has been performed in the KIT-HELOKA facility to investigate the behavior of a First Wall Mock-Up (FWMU) under Loss Of Flow Accident (LOFA) conditions. The aim of the experimental campaign was twofold: to check the expected DEMO thermal-hydraulics conditions during normal and off-normal conditions and to provide robust data for code validation. The present work is part of these validation efforts, and it deals with the analysis of the LOFA experimental campaign with the system code MELCOR 1.8.6 for fusion. A best-estimate methodology has been used in support of this analysis to ease the distinction between user’s assumptions and code limitations. The numerical analyses are here described together with their goals, achievements, and lesson learnt.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fusion materials and technologies · Nuclear reactor physics and engineering · Nuclear Engineering Thermal-Hydraulics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Dipartimento di Ingegneria Civile e Industriale, University of Pisa, Largo Lucio Lazzarino, 56122 Pisa, Italy

Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany

Funding

Euratom research and training programme 2014-2018 and 2019-2020

References (11)

Show source-provided references
1. DEMO design activity in Europe: Progress and updates10.1016/j.fusengdes.2018.04.001 ↗
2. Consolidated design of the HCPB Breeding Blanket for the pre-Conceptual Design Phase of the EU DEMO and harmonization with the ITER HCPB TBM program10.1016/j.fusengdes.2020.111614 ↗
3. Conceptual design of a First Wall Mock-Up experiment in preparation for the qualification of breeding blanket technologies in the Helium Loop Karlsruhe (HELOKA) facility10.1016/j.fusengdes.2015.12.031 ↗
4. Ghidersa, B.-E., Gonfiotti, B., Kunze, A., Di Marcello, V., Ionescu-Bujor, M., Jin, X.Z., and Stieglitz, R. (2021). Experimental investigation of a Helium-cooled Breeding Blanket First Wall under LOFA conditions and pre-test and post-test numerical analysis. Appl. Sci., 11.10.3390/app112412010 ↗
5. Overview on ITER and DEMO blanket fabrication activities of the KIT INR and related frameworks10.1016/j.fusengdes.2015.06.174 ↗
6. Preliminary Accident Analysis of Ex-Vessel LOCA for the European DEMO HCPB Blanket Concept10.1080/15361055.2021.1904769 ↗
7. Best-Estimate Model Calibration and Prediction through Experimental Data Assimilation—I: Mathematical Framework10.13182/NSE09-37B ↗
8. Gonfiotti, B., Angelucci, M., Ghidersa, B.-E., Jin, X.Z., Ionescu-Bujor, M., Paci, S., and Stieglitz, R. (2022). Best-Estimate for System Codes (BeSYC): A new soft-ware to perform Best-Estimate Plus Uncertainty analyses with thermal-hydraulic and safety system codes. Appl. Sci., 12.10.3390/app12010311 ↗
9. HELOKA facility: Thermo-hydrodynamic model and control10.1016/j.fusengdes.2008.06.016 ↗
10. Characterization of the cooling channels of First Wall Mock-Up dedicated to the HCPB TBM qualification10.1016/j.fusengdes.2017.02.072 ↗
11. A Comparative Review of Sensitivity and Uncertainty Analysis of Large-Scale Systems I: Deterministic Methods10.13182/04-54CR ↗