Evaluation of Automated Segmentation Algorithm for Macular Volumetric Measurements of Eight Individual Retinal Layer Thickness
Source abstract
Abstract
Background: We evaluated the performance of an automated algorithm available on a clinical OCT (Canon-HS100) for macular volumetric measurements of eight individual retinal layers. Methods and Analysis: Two consecutive three-dimensional scans were acquired on 29 subjects with healthy retinas. Thickness measurements were obtained from eight individual retinal layers in nine macular sectors based on Early Treatment Diabetic Retinopathy Study (ETDRS) protocol. The repeatability was evaluated using the within-subject standard deviation from which the repeatability limits (Rlimit) and coefficient of variation (CoV) were calculated. Results: The repeatability metrics varied among different layers and sectors. The variation among the sectors was larger in two of the outer layers (plexiform and nuclear layer) and the retinal nerve fiber layer. For the other five layers, the repeatability limit was less than 5µm and CoV was less than 7.5% in all nine ETDRS sectors. Conclusions: The repeatability of the OCT-HS100 to measure eight individual retinal layers is good in general. Nevertheless, the repeatability is not homogeneous among different layers and sectors. This needs to be taken into account while designing clinical measurement protocols.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Retinal Imaging and Analysis · Retinal Diseases and Treatments · Glaucoma and retinal disorders
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Division of Eye and Vision, Department of Clinical Neuroscience, Karolinska Institute, 171 77 Stockholm, Sweden
Funding
Ögonfonden
References (38)
Show source-provided references
1. Optical coherence tomography—A review of the principles and contemporary uses in retinal investigation10.1038/sj.eye.6700729 ↗
2. New developments in optical coherence tomography imaging for glaucoma10.1097/ICU.0000000000000452 ↗
3. Macular assessment using optical coherence tomography for glaucoma diagnosis10.1136/bjophthalmol-2012-301845 ↗
4. Optical coherence tomography for the monitoring of neovascular age-related macular degeneration: A systematic review10.1016/j.ophtha.2014.07.055 ↗
5. Optical coherence tomography in multiple sclerosis: A systematic review and meta-analysis10.1016/S1474-4422(10)70168-X ↗
6. Retinal nerve fiber layer thickness reproducibility using seven different OCT instruments10.1167/iovs.11-8644 ↗
7. Kansal, V., Armstrong, J.J., Pintwala, R., and Hutnik, C. (2018). Optical coherence tomography for glaucoma diagnosis: An evidence based meta-analysis. PLoS ONE, 13.10.1371/journal.pone.0190621 ↗
8. New ophthalmologic imaging techniques for detection and monitoring of neurodegenerative changes in diabetes: A systematic review10.1016/S2213-8587(15)00136-9 ↗
9. Optical coherence tomography reflects brain atrophy in multiple sclerosis: A four-year study10.1002/ana.24487 ↗
10. Progressive Loss of Retinal Ganglion Cells and Axons in Nonoptic Neuritis Eyes in Multiple Sclerosis: A Longitudinal Optical Coherence Tomography Study10.1167/iovs.15-19047 ↗
11. Spectral-Domain OCT: Helping the Clinician Diagnose Glaucoma: A Report by the American Academy of Ophthalmology10.1016/j.ophtha.2018.05.008 ↗
12. The Temporal Retinal Nerve Fiber Layer Thickness Is the Most Important Optical Coherence Tomography Estimate in Multiple Sclerosis10.3389/fneur.2017.00675 ↗
13. The association of spectral-domain optical coherence tomography determined ganglion cell complex parameters and disease severity in Parkinson’s disease10.3109/02713683.2014.894080 ↗
14. Optical coherence tomography in Parkinson’s disease: Is the retina a biomarker?10.3233/JPD-130306 ↗
15. Ellipsoid zone on optical coherence tomography: A review10.1111/ceo.12685 ↗
16. The inner segment/outer segment border seen on optical coherence tomography is less intense in patients with diminished cone function10.1167/iovs.11-8650 ↗
17. Outer retinal atrophy after regression of subretinal drusenoid deposits as a newly recognized form of late age-related macular degeneration10.1097/IAE.0b013e31829c3765 ↗
18. Outer nuclear layer thickness at the fovea determines visual outcomes in resolved central serous chorioretinopathy10.1016/j.ajo.2009.01.018 ↗
19. Changes in volume of various retinal layers over time in early and intermediate age-related macular degeneration10.1038/s41433-018-0234-9 ↗
20. Repeatability of peripapillary retinal nerve fiber layer and inner retinal thickness among two spectral domain optical coherence tomography devices10.1167/iovs.14-15072 ↗
21. Repeatability of nerve fiber layer thickness measurements in patients with glaucoma and without glaucoma using spectral-domain and time-domain OCT10.1007/s00417-011-1811-9 ↗
22. Domínguez-Vicent, A., Brautaset, R., and Venkataraman, A.P. (2019). Repeatability of quantitative measurements of retinal layers with SD-OCT and agreement between vertical and horizontal scan protocols in healthy eyes. PLoS ONE, 14.10.1371/journal.pone.0221466 ↗
23. Ctori, I., and Huntjens, B. (2015). Repeatability of Foveal Measurements Using Spectralis Optical Coherence Tomography Segmentation Software. PLoS ONE, 10.10.1371/journal.pone.0129005 ↗
24. Liu, X., Shen, M., Huang, S., Leng, L., Zhu, D., and Lu, F. (2014). Repeatability and reproducibility of eight macular intra-retinal layer thicknesses determined by an automated segmentation algorithm using two SD-OCT instruments. PLoS ONE, 9.10.1371/journal.pone.0087996 ↗
25. Terry, L., Cassels, N., Lu, K., Acton, J.H., Margrain, T.H., North, R.V., Fergusson, J., White, N., and Wood, A. (2016). Automated Retinal Layer Segmentation Using Spectral Domain Optical Coherence Tomography: Evaluation of Inter-Session Repeatability and Agreement between Devices. PLoS ONE, 11.10.1371/journal.pone.0162001 ↗
26. Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology10.1111/j.1475-1313.2011.00851.x ↗
27. Precision (repeatability and reproducibility) studies and sample-size calculation10.1016/j.jcrs.2015.06.029 ↗
28. Oberwahrenbrock, T., Weinhold, M., Mikolajczak, J., Zimmermann, H., Paul, F., Beckers, I., and Brandt, A.U. (2015). Reliability of Intra-Retinal Layer Thickness Estimates. PLoS ONE, 10.10.1371/journal.pone.0137316 ↗
29. Comparison of Individual Retinal Layer Thicknesses between Highly Myopic Eyes and Normal Control Eyes Using Retinal Layer Segmentation Analysis10.1038/s41598-019-50306-w ↗
30. Improved visualization of Henle fiber layer by changing the measurement beam angle on optical coherence tomography10.1097/IAE.0b013e3181ed8dae ↗
31. Different phenotypes of the appearance of the outer plexiform layer on optical coherence tomography10.1007/s00417-013-2308-5 ↗
32. Revealing Henle’s fiber layer using spectral domain optical coherence tomography10.1167/iovs.10-5946 ↗
33. Recognition of Henle’s fiber layer on OCT images10.1016/j.ophtha.2013.01.039 ↗
34. Analysis of Agreement of Retinal-Layer Thickness Measures Derived from the Segmentation of Horizontal and Vertical Spectralis OCT Macular Scans10.1080/02713683.2017.1406526 ↗
35. ISO Probability and General Statistical Terms (2006). Statistics: Vocabulary and symbols. Int. Organ. Stand., ISO 3534-1:2006.
36. (1994). ISO Accuracy (trueness and precision) of measurement methods and results—Part 1: General principles and definitions. Int. Organ. Stand., ISO 5725-1:1994.
37. Quantitative analysis of the inner retinal layer thicknesses in age-related macular degeneration using corrected optical coherence tomography segmentation10.1097/IAE.0000000000001759 ↗
38. Ultra-high resolution optical coherence tomography assessment of photoreceptors in retinitis pigmentosa and related diseases10.1016/j.ajo.2006.07.024 ↗