journal article·2020-07-23Open access

Intra- and Interobserver Reliability Comparison of Clinical Gait Analysis Data between Two Gait Laboratories

René Schwesig, Regina Wegener, Christof Hurschler, Kevin Laudner, Frank Seehaus

Applied Sciences· Volume 10· Issue 15

Abstract

Comparing clinical gait analysis (CGA) data between clinical centers is critical in the treatment and rehabilitation progress. However, CGA protocols and system configurations, as well as choice of marker sets and individual variability during marker attachment, may affect the comparability of data. The aim of this study was to evaluate reliability of CGA data collected between two gait analysis laboratories. Three healthy subjects underwent a standardized CGA protocol at two separate centers. Kinematic data were captured using the same motion capturing systems (two systems, same manufacturer, but different analysis software and camera configurations). The CGA data were analyzed by the same two observers for both centers. Interobserver reliability was calculated using single measure intraclass correlation coefficients (ICC). Intraobserver as well as between-laboratory intraobserver reliability were assessed using an average measure ICC. Interobserver reliability for all joints (ICCtotal = 0.79) was found to be significantly lower (p < 0.001) than intraobserver reliability (ICCtotal = 0.93), but significantly higher (p < 0.001) than between-laboratory intraobserver reliability (ICCtotal = 0.55). Data comparison between both centers revealed significant differences for 39% of investigated parameters. Different hardware and software configurations impact CGA data and influence between-laboratory comparisons. Furthermore, lower intra- and interobserver reliability were found for ankle kinematics in comparison to the hip and knee, particularly for interobserver reliability.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Diabetic Foot Ulcer Assessment and Management · Lower Extremity Biomechanics and Pathologies · Balance, Gait, and Falls Prevention

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthopaedic and Trauma Surgery, Martin-Luther-University Halle-Wittenberg, Ernst-Grube-Str. 40, 06120 Halle, Germany

Private Practice for Neurology Dr. Wegener, Lienaustr. 2, 23730 Neustadt, Holstein, Germany

Laboratory for Biomechanics and Biomaterials, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625 Hannover, Germany

Department of Health Sciences, University of Colorado, Colorado Springs, CO 80918, USA

Department of Orthopaedic Surgery, Friedrich-Alexander-University Erlangen-Nürnberg, Rathsberger Str. 57, 91054 Erlangen, Germany

References (27)

Show source-provided references
1. Instrumented gait and movement analysis of musculoskeletal diseases10.1007/s00132-012-1947-2 ↗
2. Gait analysis methods in rehabilitation10.1186/1743-0003-3-4 ↗
3. The reliability of three-dimensional kinematic gait measurements: A systematic review10.1016/j.gaitpost.2008.09.003 ↗
4. Quantitative comparison of five current protocols in gait analysis10.1016/j.gaitpost.2007.11.009 ↗
5. Interobserver variability of gait analysis in patients with cerebral palsy10.1097/01241398-200305000-00001 ↗
6. Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait10.1002/jor.1100070611 ↗
7. Intrasubject repeatability of gait analysis data in normal and spastic children10.1016/S0268-0033(99)00057-1 ↗
8. Assessment of the kinematic variability among 12 motion analysis laboratories10.1016/j.gaitpost.2008.10.060 ↗
9. Repeated measures of adult normal walking using a video tracking system10.1016/S0966-6362(97)01114-4 ↗
10. Measurement and management of errors in quantitative gait data10.1016/j.gaitpost.2003.09.011 ↗
11. Comparison of the kinematic data from three different Vicon systems. Gait Posture10.1016/S0966-6362(08)70047-X ↗
12. The reliability of hand-held dynamometry in measuring isometric strength of the shoulder internal and external rotator musculature using a stabilization device10.1080/09593980701213032 ↗
13. The reliability and concurrent validity of shoulder mobility measurements using a digital inclinometer and goniometer: A technical report
14. Measuring shoulder external and internal rotation strength and range of motion: Comprehensive intrarater and interrater reliability study of several testing protocols10.1016/j.jse.2014.01.006 ↗
15. Reliability of shoulder range of motion comparing a goniometer to a digital level10.3109/09593980903094230 ↗
16. Evaluating change in clinical status: Reliability and measures of agreement for the assessment of glenohumeral range of motion
17. Reliability of procedures used in the physical examination of non-specific low back pain: A systematic review10.1016/S0004-9514(06)70044-7 ↗
18. Wilhelmsen, K., Strand, L.I., Nordahl, S.H.G., Eide, G.E., and Ljunggren, A.E. (2008). Psychometric properties of the Vertigo symptom scale: Short form. BMC Ear Nose Throat Disord., 8.10.1186/1472-6815-8-2 ↗
19. Measurement of lower extremity kinematics during level walking10.1002/jor.1100080310 ↗
20. Data management in gait analysis for clinical applications10.1016/S0268-0033(97)00041-7 ↗
21. Intraclass correlations: Uses in assessing rater reliability10.1037/0033-2909.86.2.420 ↗
22. Statistical methods for assessing agreement between two methods of clinical measurement10.1016/S0140-6736(86)90837-8 ↗
23. Portney, L.G., and Watkins, M.P. (2009). Foundations of Clinical Research: Applications to Practice, Pearson Prentice Hall. [3rd ed.].
24. Weir, J.P. (2005). Quantifying Test-Retest Reliability Using the Intraclass Correlation Coefficient and the SEM. J. Strength Cond. Res., 19.10.1519/15184.1 ↗
25. Eta squared and partial eta squared as measures of effect size in educational research10.1016/j.edurev.2010.12.001 ↗
26. Psychotherapy of bulimia nervosa: What is effective? A meta-analysis10.1016/0022-3999(92)90024-V ↗
27. Cohen, J. (1998). Statistical Power Analysis for the Behavioural Sciences, Lawrence Erlbaum. [2nd ed.].