Distributed Passive Actuation Schemes for Seismic Protection of Multibuilding Systems
Source abstract
Abstract
In this paper, we investigate the design of distributed damping systems (DDSs) for the overall seismic protection of multiple adjacent buildings. The considered DDSs contain interstory dampers implemented inside the buildings and also interbuilding damping links. The design objectives include mitigating the buildings seismic response by reducing the interstory-drift and story-acceleration peak-values and producing small interbuilding approachings to decrease the risk of interbuilding collisions. Designing high-performance DDS configurations requires determining convenient damper positions and computing proper values for the damper parameters. That allocation-tuning optimization problem can pose serious computational difficulties for large-scale multibuilding systems. The design methodology proposed in this work—(i) is based on an effective matrix formulation of the damped multibuilding system; (ii) follows an H ∞ approach to define an objective function with fast-evaluation characteristics; (iii) exploits the computational advantages of the current state-of-the-art genetic algorithm solvers, including the usage of hybrid discrete-continuous optimization and parallel computing; and (iv) allows setting actuation schemes of particular interest such as full-linked configurations or nonactuated buildings. To illustrate the main features of the presented methodology, we consider a system of five adjacent multistory buildings and design three full-linked DDS configurations with a different number of actuated buildings. The obtained results confirm the flexibility and effectiveness of the proposed design approach and demonstrate the high-performance characteristics of the devised DDS configurations.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Vibration Control and Rheological Fluids · Seismic Performance and Analysis · Masonry and Concrete Structural Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mathematics, Universitat Politècnica de Catalunya, EPSEM, Av. Bases de Manresa 61-73, 08242 Manresa, Spain
Department of Mechanical Engineering, Politecnico di Milano, via La Masa 1, 20156 Milan, Italy
Funding
Spanish Ministry of Economy and Competitiveness · Italian Ministry of Education, University and Research under the Project
References (43)
Show source-provided references
1. Supplemental energy dissipation: state-of-the-art and state-of-the-practice10.1016/S0141-0296(01)00092-X ↗
2. Structural developments in tall buildings: Current trends and future prospects10.3763/asre.2007.5027 ↗
3. Smart passive damper control for greater building earthquake resilience in sustainable cities10.1016/j.scs.2010.08.002 ↗
4. Seismic retrofit of a high-rise steel moment-resisting frame using fluid viscous dampers10.1002/tal.1367 ↗
5. Analysis of efficiency of passive dampers in multistorey buildings10.1016/j.jsv.2018.09.031 ↗
6. Proper configuration of metallic energy dissipation system in shear-type building structures subject to seismic excitation10.1016/j.jcsr.2018.11.032 ↗
7. Design strategies of viscous dampers for seismic protection of building structures: A review10.1016/j.soildyn.2018.12.024 ↗
8. Efficiency of a simple approach to damper allocation in MDOF structures10.1002/stc.3 ↗
9. Optimization methodology for damper configuration based on building performance indices10.1061/(ASCE)0733-9445(2005)131:11(1746) ↗
10. Efficiency and tuning of viscous dampers on discrete systems10.1016/j.jsv.2004.09.022 ↗
11. An evolutionary algorithm for optimal damper placement to minimize interstorey-drift transfer function in shear building10.12989/eas.2010.1.3.289 ↗
12. Comparing fluid viscous damper placement methods considering total-building seismic performance10.1002/eqe.3117 ↗
13. Optimal seismic response control with dampers10.1002/eqe.23 ↗
14. Evaluation of genetic algorithms for the optimum distribution of viscous dampers in steel frames under strong earthquakes
15. Optimal design and distribution of viscous dampers for shear building structures under seismic excitations10.3389/fbuil.2019.00090 ↗
16. Del Gobbo, G.M. (2019, January 12–15). Placement of fluid viscous dampers to improve total-building seismic performance. Proceedings of the CSCE Annual Conference, Laval, Montreal, QC, Canada.
17. Dynamic behavior of adjacent buildings connected by linear viscous/viscoelastic dampers10.1002/stc.1734 ↗
18. An optimization study for viscous dampers between adjacent buildings10.1016/j.ymssp.2016.06.001 ↗
19. Optimal vibration control of adjacent building structures interconnected by viscoelastic dampers
20. Dynamic response of viscous damper connected similar multi-degree of freedom structures
21. Dynamic response of identical adjacent structures connected by viscous damper10.1002/stc.1566 ↗
22. Palacios-Quiñonero, F., Rubió-Massegú, J., Rossell, J.M., and Karimi, H.R. (2017). Integrated design of hybrid interstory-interbuilding multi-actuation schemes for vibration control of adjacent buildings under seismic excitations. Appl. Sci., 7.10.3390/app7040323 ↗
23. Interstory-interbuilding actuation schemes for seismic protection of adjacent identical buildings
24. Improving total-building seismic performance using linear fluid viscous dampers10.1007/s10518-018-0338-4 ↗
25. Optimal design of passive energy dissipation systems based on H∞ and H2 performances10.1002/eqe.130 ↗
26. Optimal passive-damping design using a decentralized velocity-feedback H∞ approach10.4173/mic.2012.3.1 ↗
27. Pounding hazard mitigation between adjacent planar buildings using coupling strategy10.1007/s13349-016-0177-4 ↗
28. Linking of adjacent three-storey buildings for mitigation of structural pounding during earthquakes10.1007/s10518-016-9946-z ↗
29. Design of inerter-based multi-actuator systems for vibration control of adjacent structures10.1016/j.jfranklin.2019.03.010 ↗
30. Balas, G.J., Chiang, R.Y., Packard, A.K., and Safonov, M.G. (2019). MATLAB Robust Control Toolbox User’s Guide, 2019a, The MathWorks, Inc.
31. MathWorks (2019). MATLAB Global Optimization Toolbox User’s Guide, 2019a, The MathWorks, Inc.
32. Chopra, A. (2007). Dynamics of Structures. Theory and Applications to Earthquake Engineering, Prentice Hall. [3rd ed.].
33. Decentralized H∞ controller design for large-scale civil structures10.1002/eqe.862 ↗
34. MathWorks (2019). MATLAB Control System Toolbox User’s Guide, 2019a, The MathsWorks, Inc.
35. Actual seismic response controlled building with semi-active damper system10.1002/(SICI)1096-9845(199911)28:11<1427::AID-EQE876>3.0.CO;2-# ↗
36. Wang, Q., Qiao, H., De Domenico, D., Zhu, Z., and Xie, Z. (2019). Wind-induced response control of high-rise buildings using inerter-based vibration absorbers. Appl. Sci., 9.10.3390/app9235045 ↗
37. Optimal tuned mass-damper-inerter (TMDI) design in wind-excited tall buildings for occupants’ comfort serviceability performance and energy harvesting10.1016/j.engstruct.2019.109904 ↗
38. Importance of interstory velocity on optimal along-height allocation of viscous oil dampers in super high-rise buildings10.1016/j.engstruct.2013.05.036 ↗
39. On the use of interstorey velocity for the seismic retrofit of steel frames with viscous dampers10.1016/j.soildyn.2018.07.042 ↗
40. Optimum placement of supplementary viscous dampers for seismic rehabilitation of steel frames considering soil–structure interaction10.1002/tal.1682 ↗
41. Savor Novak, M., Lazarevic, D., Atalic, J., and Uros, M. (2020). Influence of multiple-support excitation on seismic response of reinforced concrete arch bridges. Appl. Sci., 10.10.3390/app10010017 ↗
42. Optimal viscous damper placement for elastic-plastic MDOF structures under critical double impulse10.3389/fbuil.2019.00020 ↗
43. Earthquake protection of structures with nonlinear viscous dampers optimized through an energy-based stochastic approach10.1016/j.engstruct.2018.09.076 ↗