journal article·2019-11-17Open access

Evaluation of the Indoor Air Quality in Governmental Oversight Supermarkets (Co-Ops) in Kuwait

Azel Almutairi, Abdullah Alsanad, Heba Alhelailah

Applied Sciences· Volume 9· Issue 22

Abstract

Examining the indoor air environment of public venues, especially populated supermarkets such as Co-Ops in Kuwait, is crucial to ensure that these venues are safe from indoor environmental deficits such as sick building syndrome (SBS). The aim of this study was to characterize the quality of the indoor air environment of the Co-Ops supermarkets in Kuwait based on investigation of CO2, CO, NO2, H2S, TVOCs, and NMHC. On-site measurements were conducted to evaluate these parameters in three locations at the selected Co-Ops, and the perceived air quality (PAQ) was determined to quantify the air’s pollutants as perceived by humans. Moreover, the indoor air quality index (AQI) was constructed for the selected locations, and the ANOVA test was used to analyze the association between the observed concentrations among these environmental parameters. At least in one spot at each Co-Op, the tested environmental parameters exceeded the threshold limit set by the environmental agencies. The PAQ for Co-Op1, 2, and 3 are 1.25, 1.00, and 0.75 respectively. CO2 was significantly found in an association with CO, H2S, and TVOCs, and its indoor-outdoor concentrations were significantly correlated with R2 values ranges from 0.40 to 0.86 depending on the tested location.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Air Quality and Health Impacts · Air Quality Monitoring and Forecasting · Building Energy and Comfort Optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Life Sciences, Environmental Technology Management, Kuwait University, P.O. Box 5969, Safat 13060, Kuwait

References (39)

Show source-provided references
1. Investigations of indoor air quality of large department store buildings in China based on field measurements10.1016/j.buildenv.2017.03.031 ↗
2. Improving Indoor Air Quality through the Use of Ultraviolet Technology in Commercial Buildings10.1016/j.proeng.2017.08.021 ↗
3. Sick building syndrome by indoor air pollution in Dalian, China10.3390/ijerph10041489 ↗
4. Indoor environmental pollutants and their association with sick house syndrome among adults and children in elementary school10.1016/j.buildenv.2018.03.056 ↗
5. A longitudinal study of aldehydes and volatile organic compounds associated with subjective symptoms related to sick building syndrome in new dwellings in Japan10.1016/j.scitotenv.2011.12.060 ↗
6. Carbon monoxide Poisoning10.1016/j.ccc.2012.07.007 ↗
7. Carbon monoxide poisoning—A public health perspective10.1016/S0300-483X(99)00217-6 ↗
8. Inhaled carbon monoxide: From toxin to therapy10.4187/respcare.05781 ↗
9. Quantitative assessments of indoor air pollution and respiratory health in a population-based sample of French dwellings10.1016/j.envres.2011.02.008 ↗
10. Agency for Toxic Substances and Disease Registry (2019, October 19). Toxicological Profile of Hydrogen Sulfide, Available online: https://www.atsdr.cdc.gov/ToxProfiles/tp.asp?id=389&tid=67.
11. Agency for Toxic Substances and Disease Registry (2019, October 19). Toxicological Profile of Nitrogen Oxides, Available online: https://www.atsdr.cdc.gov/toxfaqs/tf.asp?id=396&tid=69.
12. Introduction of the olf and the decipol units to quantify air pollution perceived by humans indoors and outdoors10.1016/0378-7788(88)90051-5 ↗
13. Sakellaris, I.A., Saraga, D.E., Mandin, C., Roda, C., Fossati, S., de Kluizenaar, Y., Carrer, P., Dimitroulopoulou, S., Mihucz, V.G., and Szigeti, T. (2016). Perceived Indoor Environment and Occupants’ Comfort in European ‘Modern’ Office Buildings: The OFFICAIR Study. Int. J. Environ. Res. Public Health, 13.10.3390/ijerph13050444 ↗
14. EPA-US (2006). Guidelines for the Reporting of Daily Air Quality—The Air Quality Index (AQI).
15. Development of indoor environmental index: Air quality index and thermal comfort index10.1063/1.4975276 ↗
16. Wang, H. (2018, January 12–16). Developing an indoor air quality index system based on the health risk assessment. Proceedings of the 11th International Conference on Air Quality and Climate, Barcelona, Spain.
17. Aeroqual (2019, October 20). What’s Best for Measuring Ozone, Electrochemical Sensors or HMOS?. Available online: https://www.aeroqual.com/electrochemical-sensors-hmos.
18. Capturing the sensitivity of land-use regression models to short-term mobile monitoring campaigns using air pollution micro-sensors10.1016/j.envpol.2017.06.071 ↗
19. Spinelle, L., Gerboles, M., Kok, G., Persijn, S., and Sauerwald, T. (2017). Review of portable and low-cost sensors for the ambient air monitoring of benzene and other volatile organic compounds. Sensors, 17.10.3390/s17071520 ↗
20. Schütze, A., Baur, T., Leidinger, M., Reimringer, W., Jung, R., Conrad, T., and Sauerwald, T. (2017). Highly Sensitive and Selective VOC Sensor Systems Based on Semiconductor Gas Sensors: How to?. Environments, 4.10.3390/environments4010020 ↗
21. Peterson, P.J.D., Aujla, A., Grant, K.H., Brundle, A.G., Thompson, M.R., Vande Hey, J., and Leigh, R.J. (2017). Practical use of metal oxide semiconductor gas sensors for measuring nitrogen dioxide and ozone in urban environments. Sensors, 17.10.3390/s17071653 ↗
22. Szulczyński, B., and Gębicki, J. (2017). Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air. Environments, 4.10.3390/environments4010021 ↗
23. Impacts of air conditioning on air quality in tiny homes in Hong Kong10.1016/j.scitotenv.2019.05.354 ↗
24. Effects of air pollution on carbon sequestration potential in two tropical forests of West Bengal, India10.1016/j.ecolind.2018.11.014 ↗
25. Reliable data from low cost ozone sensors in a hierarchical network10.1016/j.atmosenv.2019.116870 ↗
26. Cardiorespiratory responses to low-level ozone exposure: The inDoor Ozone Study in childrEn (DOSE)10.1016/j.envint.2019.105021 ↗
27. Spatial-temporal variations of summertime ozone concentrations across a metropolitan area using a network of low-cost monitors to develop 24 hourly land-use regression models10.1016/j.scitotenv.2018.11.111 ↗
28. Evaluation and calibration of Aeroqual series 500 portable gas sensors for accurate measurement of ambient ozone and nitrogen dioxide10.1016/j.atmosenv.2014.11.002 ↗
29. Continuous IEQ monitoring system: Performance specifications and thermal comfort classification10.1016/j.buildenv.2018.12.016 ↗
30. Streamlining IAQ guidelines and investigating the effect of door opening/closing on concentrations of VOCs, formaldehyde, and NO2 in office buildings10.1016/j.buildenv.2018.03.029 ↗
31. ASHRAE (2016). Standard 62.1-Ventilation for Acceptable Indoor Air Quality, ASHRAE.
32. EPA-Kuwait (2014). Rules and Regulations—Standards.
33. Investigation of indoor air quality in shopping malls during summer in Western China using subjective survey and field measurement10.1016/j.buildenv.2016.08.012 ↗
34. Indoor Air Quality and Sick Building Syndrome Among Nigerian Laboratory University Workers10.21315/jps2019.30.1.13 ↗
35. Indoor air quality evaluation of two museums in a subtropical climate conditions10.1016/j.scs.2015.10.002 ↗
36. Indoor air pollution levels in public buildings in Thailand and exposure assessment10.1007/s10661-008-0507-z ↗
37. Nitrogen Dioxide in Indoor Ice Skating Facilities: An International Survey10.1080/10473289.1997.10464399 ↗
38. Tang, J.H., Chan, L.Y., Chang, C.C., Liu, S., and Li, Y.S. (2009). Characteristics and sources of non-methane hydrocarbons in background atmospheres of eastern, southwestern, and southern China. J. Geophys. Res., 114.10.1029/2008JD010333 ↗
39. Cashman, J. (2008). International Chemical Safety Cards. Emergency Response Handbook for Chemical and Biological Agents and Weapons, CRC Press. [2nd ed.]. Available online: http://www.ilo.org/dyn/icsc/showcard.listCards3.