Analyses of the Temperature Field of a Piezoelectric Micro Actuator in the Endoscopic Biopsy Channel
Source abstract
Abstract
Micro actuators have been used to realize the arrival of digestive tract lesions for the local targeted application of drugs in endoscopes. However, there still exists a key safety issue that casts a shadow over the practical and safe implementation of actuators in the human body, namely an overheated environment caused by actuators’ operation. Herein, with the aim of solving the temperature rising problem of a piezoelectric micro actuator operating in an endoscopic biopsy channel (OLYMPUS, Tokyo, Japan), a thermal finite element method (FEM) based on COMSOL Multiphysics software is proposed. The temperature distribution and its rising curves are obtained by the FEM method. Both the simulated and experimental maximum temperatures are larger than the safety value (e.g., 42 °C for human tissues) when the driving voltage of the actuator is 200 Vpp, which proves that the overheating problem really exists in the actuator. Furthermore, the results show that the calculated temperature rising curves correspond to the experimental results, proving the effectiveness of this FEM method. Therefore, we introduce a temperature control method through optimizing the duty ratio of the actuator. In comparison with a 100% duty ratio operation condition, it is found that a 60% duty ratio with a driving voltage of 200 Vpp can more effectively prevent the temperature rising issue in the first 3 min, as revealed by the corresponding temperatures of 44.4 and 41.4 °C, respectively. When the duty ratio is adjusted to 30% or less, the temperature rise of the actuator can be significantly reduced to only 36.6 °C, which is close to the initial temperature (36.4 °C). Meanwhile, the speed of the actuator can be well-maintained at a certain level, demonstrating its great applicability for safe operation in the human body.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · 3D Printing in Biomedical Research · Heat Transfer and Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Lab of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics & Astronautics, Nanjing 210016, China
Funding
National Natural Science Foundation of China · Outstanding Youth Science Foundation of Jiangsu Province
References (34)
Show source-provided references
1. Stationary-fiber rotary probe with unobstructed 360°10.1364/OL.36.004392 ↗
2. Ultrasonic Motor for Driving OCT Endoscopic
3. Su, Q., Quan, Q., Deng, J., and Yu, H. (2018). A Quadruped Micro-Robot Based on Piezoelectric Driving. Sensors, 18.10.3390/s18030810 ↗
4. Wang, S., Housden, R.J., Noh, Y., Singh, A., Lindenroth, L., Liu, H., Althoefer, K., Hajnal, J., Singh, D., and Rhode, K. (2019). Analysis of a Customized Clutch Joint Designed for the Safety Management of an Ultrasound Robot. Appl. Sci., 9.10.3390/app9091900 ↗
5. Clinical impact of endoscopic clip closure of perforations during endoscopic submucosal dissection for colorectal tumors10.1016/j.gie.2016.01.014 ↗
6. Additional surgical resection after endoscopic mucosal dissection for early gastric cancer: A medium-sized hospital’s experience10.1016/j.ijsu.2016.11.084 ↗
7. Complications of endoscopic polypectomy, endoscopic mucosal resection and endoscopic submucosal dissection in the colon10.1016/j.bpg.2016.09.009 ↗
8. Evaluation of hemostasis with soft coagulation using endoscopic hemostatic forceps in comparison with metallic hemoclips for bleeding gastric ulcers: A prospective, randomized trial10.1007/s00535-009-0186-8 ↗
9. Active gastrointestinal bleeding: Use of hemostatic forceps beyond endoscopic submucosal dissection10.3748/wjg.v16.i16.2061 ↗
10. Application of endoscopic hemostatic forceps for uterine cervical bleeding10.1016/j.gie.2014.04.023 ↗
11. Endoscopic hemostatic devices10.1016/S0016-5107(01)70088-0 ↗
12. Endoscopic treatment of acute variceal hemorrhage by using hemostatic powder TC-325: A prospective pilot study10.1016/j.gie.2013.07.037 ↗
13. Endoscopic hemostatic treatment under irrigation for upper-GI hemorrhage: A comparison of one third and total circumference transparent end hoods10.1016/S0016-5107(04)00171-3 ↗
14. Improving Conventional or Low Dose Metronomic Chemotherapy with Targeted Antiangiogenic Drugs10.4143/crt.2007.39.4.150 ↗
15. Multidisciplinary treatment with chemotherapy, targeted drug, and high-intensity focused ultrasound in advanced pancreatic carcinoma10.1007/s12032-011-9892-1 ↗
16. Nanoscale drug delivery for targeted chemotherapy10.1016/j.canlet.2016.05.023 ↗
17. Chemotherapy plus targeted drugs in conversion therapy for potentially resectable colorectal liver metastases: A meta-analysis10.18632/oncotarget.9675 ↗
18. Onishi, K., Sewa, S., and Asaka, K. (2000, January 23–27). Biomimetic microactuators based on polymer electrolyte/gold composite driven by low voltage. Proceedings of the Thirteenth International Conference on Micro Electro Mechanical Systems, Miyazaki, Japan.
19. Boucaud, A., Montharu, J., Lebertre, M., Patat, F., Vaillant, L., and Machet, L. (1999, January 17–20). Biological effects of low frequency ultrasound on the skin. Proceedings of the Ultrasonics Symposium, Caesars Tahoe, NV, USA.
20. Frequency and thermal effects on the enhancement of transdermal transport by sonophoresis10.1016/S0168-3659(02)00464-9 ↗
21. Clinical, histologic, and electron microscopy study of skin exposed to low-frequency ultrasound10.1002/ar.1122 ↗
22. High speed locomotion for a quadrupedal microrobot10.1177/0278364914521473 ↗
23. A New Low-frequency Sonophoresis System Combined with Ultrasonic Motor and Transducer10.1088/1361-665X/aaad9c ↗
24. A novel piezoelectric actuator with a screw-coupled stator and rotor for driving an aperture10.1088/0964-1726/25/3/035027 ↗
25. A novel traveling wave piezoelectric actuated tracked mobile robot utilizing friction effect10.1088/1361-665X/26/3/035003 ↗
26. Ultra-compact, zero-power magnetic latching piezoelectric inchworm motor with integrated position sensor10.1016/j.sna.2010.01.022 ↗
27. Development of a high-speed synchronous micro motor and its application in intravascular imaging10.1016/j.sna.2014.07.020 ↗
28. Bio-effects and safety of low-intensity, low-frequency ultrasonic exposure10.1016/j.pbiomolbio.2012.01.004 ↗
29. Taheri, H., and Hassen, A.A. (2019). Nondestructive Ultrasonic Inspection of Composite Materials: A Comparative Advantage of Phased Array Ultrasonic. Appl. Sci., 9.10.3390/app9081628 ↗
30. A light-weight surface milli-walker based on piezoelectric actuation10.1109/TIE.2018.2883269 ↗
31. Zhao, C. (2011). Ultrasonic Motors Technologies and Applications, Springer.10.1007/978-3-642-15305-1 ↗
32. Active vibration control of plates using positive position feedback control with PZT actuators10.3397/1/376378 ↗
33. Polyimide/substituted polyaniline-copolymer-nanoclay composite thin films with high damping abilities10.1002/app.36794 ↗
34. Crack propagation in a glass particle-filled epoxy resin10.1007/BF02403234 ↗