Influence of Chip Materials on Charge Generation in Flowing Solution in Nanobiosensors
Source abstract
Abstract
Nowadays, nanobiosensors are being intensively developed due to the potential possibilities of their use for early diagnosis of diseases. This interest is enhanced by the fact that, as is known, a pathological process at an early stage is characterized by the appearance of marker proteins at very low (10−15 M and lower) concentrations in blood. Highly-sensitive nanobiosensor systems (including those based on an atomic force microscope, AFM) allows one to detect proteins at such low concentrations. The influence of the charge generated in the analyte solution flowing through the biosensor injector into the measuring cell during measurements is considered to be an important factor conditioning such a high detection sensitivity. In the present study, it was demonstrated that the presence of an AFM chip (made of mica and graphite) near the nozzle of the injector supplying an analyte solution into the measuring cell of the AFM-based fishing system (AFM-based nanobiosensors) causes an increase in charge generation upon the injection of the solution. Moreover, the influence of polymer materials (which are widely used in nanobiosensors) and communications on charge generation in the flow-based section of AFM-based nanobiosensors was studied. A stimulating influence of a low (femtomolar) concentration of proteins on the charge generation in polymeric injectors of flow-based nanobiosensors was demonstrated. Besides, a stimulating influence of an external low-frequency AC electric field on the charge generation in the nanobiosensor injector was found. Measurements were carried out in the temperature range corresponding to the physiological temperature (35 °C).
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · Microfluidic and Bio-sensing Technologies · Advanced Biosensing Techniques and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Biomedical Chemistry, Moscow 119121, Russia
Foundation of Perspective Technologies and Novations, Moscow 115682, Russia
Skryabin Moscow State Academy of Veterinary Medicine and Biotechnology, Moscow 109472, Russia
Joint Institute for High Temperatures of the Russian Academy of Sciences, Moscow 125412, Russia
References (21)
Show source-provided references
1. Single-molecule enzyme-linked immunosorbent assay detects serum proteins at subfemtomolar concentrations10.1038/nbt.1641 ↗
2. Highly sensitive protein detection by combination of atomic force microscopy fishing with charge generation and mass spectrometry analysis10.1111/febs.13011 ↗
3. ViriChip: A solid phase assay for detection and identification of viruses by atomic force microscopy10.1088/0957-4484/15/3/027 ↗
4. Label-Free Protein and Pathogen Detection Using the Atomic Force Microscope10.1177/1087057104268803 ↗
5. Electrical detection of single viruses10.1073/pnas.0406159101 ↗
6. Highly sensitive protein detection by biospecific AFM-based fishing with pulsed electrical stimulation10.1002/2211-5463.12253 ↗
7. Spontaneous electrical charging of droplets by conventional pipetting10.1038/srep02037 ↗
8. A physicochemical explanation for flow electrification in low-conductivity liquids10.1109/28.536865 ↗
9. Conversion of ortho-para H2O isomers in water and a jump in erythrocyte fluidity through a microcapillary at a temperature of 36.6 ± 0.3 °C10.3103/S1541308X09040025 ↗
10. Ivanov, Y.D., Kozlov, A.F., Galiullin, R.A., Tatur, V.Y., Ziborov, V.S., Usanov, S.A., and Pleshakova, T.O. (2018). Influence of a Pulsed Electric Field on Charge Generation in a Flowing Protein Solution. Separations, 5.10.3390/separations5020029 ↗
11. Influence of AC electric field on the charge generation in albumin solution in a flow-based AFM fishing system10.1088/1757-899X/443/1/012011 ↗
12. Where is water in the triboelectric series?10.1016/j.elstat.2016.01.002 ↗
13. Comparative study of self-organization and physicochemical properties of highly diluted aqueous solutions of phenol bioantioxidants10.1134/S0012501612110036 ↗
14. Nanoassociate formation in highly diluted water solutions of potassium phenosan with and without permalloy shielding10.3109/15368378.2015.1036070 ↗
15. The Effect of Pulsed Electric Field on the Generation of Charge in Flow-Based Medical and Diagnostic Systems10.1007/s10527-018-9819-7 ↗
16. Electrostatic Charging Due to Separation of Ions at Interfaces: Contact Electrification of Ionic Electrets10.1002/anie.200701812 ↗
17. Spontaneous generation of charge in the flow-based AFM fishing system10.1016/j.elstat.2017.11.003 ↗
18. Two Types of Anomalous Thermodynamics of Water
19. Pershin, S.M. (2019, February 05). New conception considering the impact of EMF on water/water solutions with account for quantum differences between ortho- and para-isomers of H2O. Available online: http://www.biophys.ru/archive/sarov2013/proc-p17.pdf.
20. The extraordinary ligand binding properties of human serum albumin10.1080/15216540500404093 ↗
21. Coherent laser spectroscopy of hydration processes of biomolecules and nanoparticles