Evaluation of the Electromyography Test for the Analysis of the Aerobic-Anaerobic Transition in Elite Cyclists during Incremental Exercise

Iban Latasa, Alfredo Cordova, Gregorio Quintana-Ortí, Ana Lavilla-Oiz, Javier Navallas, Javier Rodriguez-Falces

Applied Sciences· Volume 9· Issue 3

Abstract

(1) Background: The aim of this study was to investigate the validity and reliability of surface electromyography (EMG) for automatic detection of the aerobic and anaerobic thresholds during an incremental continuous cycling test using 1 min exercise periods in elite cyclists. (2) Methods: Sixteen well-trained cyclists completed an incremental exercise test (25 W/1 min) to exhaustion. Surface bipolar EMG signals were recorded from the vastus lateralis, vastus medialis, biceps femoris, and gluteus maximus, and the root mean square (RMS) were assessed. The multi-segment linear regression method was used to calculate the first and second EMG thresholds (EMGT1 and EMGT2). During the test, gas exchange data were collected to determine the first and second ventilatory thresholds (VT1 and VT2). (3) Results: Two breakpoints (thresholds) were identified in the RMS EMG vs. time curve for all muscles in 75% of participants. The two breakpoints, EMGT1 and EMGT2, were detected at around 70%–80% and 90%–95% of VO2MAX, respectively. No significant differences were found between the means of VT1 and EMGT1 for the vastii and biceps femoris muscles (p > 0.05). There were no significant differences between means of EMGT2 and VT2 (p > 0.05). (4) Conclusions: It is concluded that the multi-segment linear regression algorithm is a valid non-invasive method for analyzing the aerobic-anaerobic transition during incremental tests with 1 min stage durations.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Muscle activation and electromyography studies · Sports Performance and Training · Cardiovascular and exercise physiology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electrical and Electronical Engineering, Campus de Arrosadía s/n, Public University of Navarra, 31006 Pamplona, Spain

Department of Physiology and Biochemistry, University of Valladolid, 42004 Soria, Spain

Department of Engineering and Computer Science, University Jaime I, Campus Riu Sec, 12071 Castellón, Spain

Pediatric Neurology Unit, Virgen del Camino Hospital, 31008 Pamplona, Spain

References (43)

Show source-provided references
1. The aerobic-anaerobic transition: Re-examination of the threshold concept including an electromyographic approach10.1007/BF00424804 ↗
2. EMG signs of neuromuscular fatigue related to the ventilatory threshold during cycling exercise10.1046/j.1475-097X.2003.00497.x ↗
3. Intersession reliability of the EMG signal during incremental cycle ergometry: Quadriceps femoris10.1002/mus.22211 ↗
4. The extraction of neural strategies from the surface EMG10.1152/japplphysiol.01070.2003 ↗
5. Detecting fatigue thresholds from electromyographic signals: A systematic review on approaches and methodologies10.1016/j.jelekin.2016.08.002 ↗
6. Analysis of the aerobic-anaerobic transition in elite cyclists during incremental exercise with the use of electromyography
7. Validity of electromyographic fatigue threshold as a noninvasive method for tracking changes in ventilator threshold in college-aged men10.1519/JSC.0b013e31819b79bc ↗
8. Objectivity and validity of EMG method in estimating anaerobic threshold10.1055/s-0033-1361182 ↗
9. Comparing the lactate and EMG thresholds of recreational cyclists during incremental pedaling exercise10.1139/Y08-020 ↗
10. Leg electromyography and the VO2-power relationship during bicycle ergometry10.1097/00005768-200107000-00025 ↗
11. Occurrence of electromyographic and ventilatory thresholds in professional road cyclists10.1007/s00421-003-0949-5 ↗
12. Electromyographic activity related to aerobic and anaerobic threshold in ergometer bicycling10.1111/j.1748-1716.1985.tb07663.x ↗
13. Association between the electromyographic fatigue threshold and ventilator threshold
14. Relationship between ventilatory threshold and muscle fiber conduction velocity responses in trained cyclists10.1016/j.jelekin.2012.10.005 ↗
15. EMG versus oxygen uptake during cycling exercise in trained and untrained subjects10.1016/S1050-6411(03)00081-6 ↗
16. Non-invasive assessment of muscle fiber conduction velocity during an incremental maximal cycling test10.1016/j.jelekin.2009.03.008 ↗
17. Muscle fibre conduction velocity and cardiorespiratory response during incremental cycling exercise in young and older individuals with different training status10.1016/j.jelekin.2010.02.004 ↗
18. Exercise-induced oxidative stress influences the motor control during maximal incremental cycling exercise in healthy humans10.1016/j.resp.2013.02.027 ↗
19. An EMG frequency-based test for estimating the neuromuscular fatigue threshold during cycle ergometry10.1007/s00421-009-1239-7 ↗
20. Detecting the threshold of anaerobic metabolism in cardiac patients during exercise10.1016/0002-9149(64)90012-8 ↗
21. Hermens, H.J., Freriks, B., Merletti, R., Stegeman, D., Blok, J., Rau, G., Disselhorst-Klug, C., and Hägg, G.M. (1999). European Recommendations for Surface Electromyography: Results of the SENIAM Project Roessingh Research and Development, SENIAM.
22. Statistical methods for assessing agreement between methods of clinical measurement10.1016/S0140-6736(86)90837-8 ↗
23. A review of metabolic and physiological factors in fatigue
24. Lactate inhibits Ca2+-activated Ca2+-channel activity from skeletal muscle sarcoplasmic reticulum10.1152/jappl.1997.82.2.447 ↗
25. Amplitude-related characteristics of motor unit and M-wave potentials during fatigue. A simulation study using literature data on intracellular potential changes found in vitro10.1016/S1050-6411(02)00046-9 ↗
26. Real-time evaluation of the anaerobic threshold with rms-EMG of working and nonworking muscles during incremental bicycle ergometer test10.3727/036012992816357701 ↗
27. “Muscular wisdom” that minimizes fatigue during prolonged effort in man: Peak rates of motoneuron discharge and slowing of discharge during fatigue
28. Estimation of the neuromuscular fatigue threshold from an incremental cycling test using 1-minute exercise periods10.23736/S0022-4707.16.05768-6 ↗
29. Identifying the integrated electromyographic threshold using different muscles during incremental cycling exercise
30. Quadriceps Muscles O2 Extraction and EMG Breakpoints during a Ramp Incremental Test10.3389/fphys.2017.00686 ↗
31. Breakpoints in ventilation, cerebral and muscle oxygenation, and muscle activity during an incremental cycling exercise
32. Mello, R.G.T., Oliveira, L.F., and Nadal, J. (September, January 30). Detection of the anaerobic threshold by surface electromyography. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, New York, NY, USA.
33. The electromyographic threshold in boys and men10.1007/s00421-015-3100-5 ↗
34. Aerobic-anaerobic transition intensity measured via EMG signals in athletes with different physical activity patterns10.1007/s00421-007-0509-5 ↗
35. On the biomechanics of cycling. A study of joint and muscle load during exercise on the bicycle ergometer
36. Changes of pedaling technique and muscle coordination during an exhaustive exercise10.1249/MSS.0b013e31819825f8 ↗
37. The effect of prolonged cycling on pedal forces10.1080/0264041031000071010 ↗
38. Effect of metabolic products of muscular contraction on discharge of group III and IV afferents10.1152/jappl.1988.64.6.2306 ↗
39. Mechanisms of fatigue-induced activation of group IV muscle afferents: The roles played by lactate and inflammatory mediators10.1016/S0304-3940(98)00816-7 ↗
40. Reflex cardio-vascular and respiratory responses originating in exercising muscle10.1113/jphysiol.1972.sp009887 ↗
41. Reflex inputs to the cardiovascular and respiratory centers from dynamically working canine muscles10.1161/01.RES.41.3.332 ↗
42. Coincidental changes in ventilation and electromyographic activity during consecutive incremental exercise tests10.1007/BF00599242 ↗
43. Maximal lactate steady state, critical power and EMG during cycling10.1007/s00421-002-0703-4 ↗