Numerical and Experimental Study on Enhancing Performance of the Stand Fan
Source abstract
Abstract
To meet humans’ need of enhancing the quality of life, the high-performance stand fan has become an essential appliance in every family. On the other hand, energy saving can not only solve the problem of environment protection, but also can reduce the cost of energy consumption. However, the aerodynamic performance and flow characteristics of the stand fan are rarely investigated and analyzed in a systematical manner. Therefore, this research intends to investigate the physical mechanism of the flow pattern and identify the design parameters of the stand fan by combining numerical and experimental methods. First of all, both the structure and performance of a commercial 14-inch stand fan are chosen for analysis and are set as the reference for the fan. The stand fan can be divided into the impeller and the protective cover. Clearly, the impeller blades have a great influence on the fan performance, so they are the first design target. In this work, CFD (computational fluid dynamics) software Fluent (version 14.5, ANSYS Inc., Canonsburg, PA, USA, 2012) is used to analyze and observe the corresponding influences on flow fields and aerodynamic performance by changing the design parameters such as the setting, twist, and inclination angles. Then, the protective cover is studied, improved and integrated with the designed impeller to further enhance the performance of the fan. The protective cover is modified by varying the spacing between the blade tip and cover, as well as varying the shape and angle of ribs to improve the fan’s flow field and performance. Finally, the optimal fan mockup is made via CNC (computer numerical control) technology. Also, its acoustics and performance have been measured to validate the accuracy and reliability of the numerical simulation. The testing results show that the optimally designed stand fan is better than the reference fan with a significant 54% increase in max flow rate. In addition, it has more uniform velocity distribution compared with the reference fan to achieve a comfortable feeling for the human body. In summary, this research successfully establishes a reliable and systematic scheme to design the stand fan. Also, the corresponding performance influences caused by those important parameters are analyzed and summarized to serve as the design reference for the stand fan.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Heat Transfer Mechanisms · Fluid Dynamics and Turbulent Flows · Aerodynamics and Acoustics in Jet Flows
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
Department of Mechanical Engineering, Far East University, Tainan 74448, Taiwan
Industrial Technology Research Institute, Hsinchu 31040, Taiwan
Funding
the Ministry of Science and Technology in Taiwan
References (17)
Show source-provided references
1. Balje, O.E. (1981). Turbomachines—A Guide to Design, Selection and Theory, John Wiley.10.1115/1.3241788 ↗
2. The effects of tip clearance on the performance of an axial flow fan10.1016/0196-8904(92)90094-D ↗
3. An integrated experimental and numerical study of forward-curved centrifugal fan10.1016/S0894-1777(02)00112-7 ↗
4. An integrated performance analysis for a small axial-flow fan10.1243/09544062JMES1829 ↗
5. An integrated study on the design method for small axial-flow fans, based on the airfoil theory10.1243/09544062JMES2231 ↗
6. An integrated performance analysis for a backward-inclined centrifugal fan10.1016/j.compfluid.2011.11.009 ↗
7. An integrated numerical and experimental analysis for enhancing the performance of the hidden ceiling fan10.1155/2014/214967 ↗
8. (2012). ANSYS Fluent User’s Guide-14.5, ANSYS Inc.
9. A calculation procedure for heat mass and momentum transfer in three-dimensional parabolic flows10.1016/0017-9310(72)90054-3 ↗
10. Hinze, J.O. (1975). Turbulence, McGraw-Hill.
11. Launder, B.E., and Spalding, D.B. (1972). Lectures in Mathematical Models of Turbulence, Academic Press.
12. Ariff, M., Salim, S.M., and Cheah, S.C. (June, January 30). Wall y+ approach for dealing with turbulent flow over a surface mounted cube: Part 1—Low Reynolds number. Proceedings of the Seventh International Conference on CFD in the Minerals and Process Industries CSIRO, Melbourne, Australia.
13. Ariff, M., Salim, S.M., and Cheah, S.C. (June, January 30). Wall y+ approach for dealing with turbulent flow over a surface mounted cube: Part 2—High Reynolds number. Proceedings of the Seventh International Conference on CFD in the Minerals and Process Industries CSIRO, Melbourne, Australia.
14. (2011). ENERGY STAR® Laboratory Guidance Manual: Building a Testing Facility and Performing the Solid State Test Method for ENERGY STAR Qualification of Ceiling Fans, ENERGY STAR.
15. CNS 2061 (1992). Electric Fan (Stand Type), Chinese National Standard.
16. CNS 8753 (1982). Determination of Sound Power Level of Noises for Fan, Blower, and Compressors, Chinese National Standard.
17. ISO 3745 (2003). Acoustics—Determination of Sound Power Levels of Noise Sources Using Sound Pressure—Precision Methods for Anechoic and Hemi-Anechoic Rooms, ISO.