Cardiac Radiofrequency Ablation Simulation Using a 3D-Printed Bi-Atrial Thermochromic Model
Source abstract
Abstract
Radiofrequency ablation (RFA) is a treatment used in the management of various arrhythmias including atrial fibrillation. Enhanced training for electrophysiologists through the use of physical simulators has a significant role in improving patient outcomes. The requirements for a high-fidelity simulator for cardiac RFA are challenging and not fully met by any research or commercial simulator at present. In this study, we have produced and evaluated a 3D-printed, bi-atrial model contained in a custom-made enclosure for RFA simulation using a new soft tissue-mimicking polymer, Layfomm-40, combined with thermochromic pigment and barium sulphate in an acrylic paint carrier. We evaluated the conductive properties of Layfomm-40, its sensitivity to RFA, and its visibility in X-ray imaging, and carried a full simulation of RFA in the cardiac catheterization laboratory by an electrophysiologist. We demonstrated that a patient-specific 3D-printed Layfomm-40 bi-atrial model coated with a custom thermochromic/barium sulphate paint was compatible with the CARTO3 electroanatomic mapping system and could be effectively imaged using X-ray fluoroscopy. We demonstrated the effective delivery and visualization of radiofrequency ablation lesions in this model. The simulator meets nearly all the requirements for high-fidelity physical simulation of RFA. The use of such simulators is likely to have impact on the training of electrophysiologists and the evaluation of novel RFA devices.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Cardiac Arrhythmias and Treatments · Atrial Fibrillation Management and Outcomes · Cardiac electrophysiology and arrhythmias
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Surgical & Interventional Engineering, School of Biomedical Engineering & Imaging Sciences, King’s College London, St. Thomas Hospital, London SE1 7EH, UK
Centre for Cardiovascular Science, The University of Edinburgh, Edinburgh EH8 9YL, UK
Funding
National Institute for Health Research Biomedical Research Centre at Guy’s and St. Thomas’ NHS Foundation Trust and King’s College London, the Wellcome/EPSRC Centre for Medical Engineering · KCL-China Scholarship Scheme · British Heat Foundation
References (17)
Show source-provided references
1. Catheter Ablation for the Management of Atrial Fibrillation: Current Technical Perspectives10.1136/openhrt-2019-001207 ↗
2. Simulator Training Reduces Radiation Exposure and Improves Trainees’ Performance in Placing Electrophysiologic Catheters during Patient-based Procedures10.1016/j.hrthm.2012.04.015 ↗
3. Development of Simulation Combining a Physical Heart Model and Three-dimensional System for Electrophysiology Training10.1111/pace.13508 ↗
4. Better Lesion Creation and Assessment during Catheter Ablation
5. A Polyacrylamide Gel Phantom for Radiofrequency Ablation10.1080/02656730802104732 ↗
6. Thermochromic Tissue-mimicking Phantom for Optimisation of Thermal Tumour Ablation10.3109/02656736.2016.1145745 ↗
7. 3D Printed Bio-Models for Medical Applications10.1108/RPJ-08-2015-0102 ↗
8. Development and Testing of an Ultrasound-Compatible Cardiac Phantom for Interventional Procedure Simulation Using Direct Three-Dimensional Printing10.1089/3dp.2019.0097 ↗
9. T 1-mapping and Dielectric Properties Evaluation of A 3D Printable Rubber-Elastomeric Polymer as Tissue Mimicking Materials for MRI Phantoms10.1088/2053-1591/abc76f ↗
10. Talalwa, L., Gordji-Nejad, A., Natour, G., Drzezga, A., Bauer, A., and Beer, S. (November, January 26). Evaluation of 3D Printable Rubber-Elastomeric Polymer as Phantom Material for Hybrid PET/MRI. Proceedings of the IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Manchester, UK.
11. Nguyen, D.K., Bach, Q.-V., Lee, J.-H., and Kim, I.-T. (2018). Synthesis and Irreversible Thermochromic Sensor Applications of Manganese Violet. Materials, 11.10.3390/ma11091693 ↗
12. Fan, M., and Fu, F. (2017). Temperature Sensitive Colour-changed Composites. Advanced High Strength Natural Fibre Composites in Construction, Woodhead Publishing.10.1016/B978-0-08-100411-1.00006-6 ↗
13. Electrical conductivity and permittivity of murine myocardium10.1109/TBME.2009.2012401 ↗
14. (2021, November 08). Thermal Conductivity » IT’IS Foundation. Available online: https://itis.swiss/virtual-population/tissue-properties/database/thermal-conductivity.
15. Right Atrial Dimensions and Volume Estimation by Steady State Free Precession Cardiovascular Magnetic Resonance10.1186/1532-429X-15-29 ↗
16. Masnok, K., and Watanabe, N. (2021, January 23–25). Role of Catheter Contact Force on Biophysical Properties of the Ablation Lesion Formation in Radiofrequency Catheter Cardiac Ablation. Proceedings of the IEEE Region 10 Symposium (TENSYMP), Jeju-si, Korea.10.1109/TENSYMP52854.2021.9550864 ↗
17. Russell, W.M.S., and Burch, R.L. (1959). The Principles of Humane Experimental Technique, Methuen.