Highlighting Specific Features to Reduce Chemical and Thermal Risks of Electronic Cigarette Use through a Technical Classification of Devices
Source abstract
Abstract
Currently, the emission generation protocol of electronic cigarettes has only one standardized vaping regimen that is consistent with mouth-to-lungs inhalation. Recent works show the significant increase in performance of the device with the use of a direct lung vaping regimen (167 mL s−1, consistent with direct lung inhalation). However, requirements are needed for its use in a laboratory. This work aims at identifying mechanical characteristics of a device and providing a classification based on recommended power range, electrical resistance, heating surface, and air resistance of twenty-six tested devices. The electrical resistivity relation allows the estimation of the wire surface using its diameter and its length. The air resistance is obtained by measuring the pressure drop of the tested device with airflow rates ranging from 1–10 L min−1. Through the wide panel of tested devices, results allow separating them in two categories: classical and sub-ohm electronic cigarettes consistent with the two inhalation behaviours. Differences up to 71 mm2 for the wire surface and up to 4.8 Pa 0.5 min L−1 for the air resistance are observed between them. This limit seems to correspond to a required power of 25 W and an electrical resistance of 1.1 Ω.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Air Quality and Health Impacts · Combustion and Detonation Processes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Ingésciences, 2 Chemin des Arestrieux, 33610 Cestas, France
Bordeaux INP, CNRS, I2M Bordeaux, ENSCBP, 16 Avenue Pey Berland, CEDEX, 33607 Pessac, France
References (18)
Show source-provided references
1. (2021, February 02). ANSES; Déclarations Des Produits Du Tabac et Produits Connexes En France—Produits Du Vapotage—Bilan 2016–2020. Available online: https://www.anses.fr/fr/system/files/CONSO2018SA0189Ra-2.pdf.
2. Williams, M., and Talbot, P. (2019). Design Features in Multiple Generations of Electronic Cigarette Atomizers. Int. J. Environ. Res. Public Health, 16.10.3390/ijerph16162904 ↗
3. Soulet, S., Duquesne, M., Toutain, J., Pairaud, C., and Lalo, H. (2018). Influence of Coil Power Ranges on the E-Liquid Consumption in Vaping Devices. Int. J. Environ. Res. Public Health, 15.10.3390/ijerph15091853 ↗
4. Hot Wires and Film Boiling: Another Look at Carbonyl Formation in Electronic Cigarettes10.1021/acs.chemrestox.0c00196 ↗
5. Soulet, S., Duquesne, M., Toutain, J., Pairaud, C., and Mercury, M. (2019). Impact of Vaping Regimens on Electronic Cigarette Efficiency. Int. J. Environ. Res. Public Health, 16.10.3390/ijerph16234753 ↗
6. ISO (2018). ISO/20768—Vapour Products—Routine Analytical Vaping Machine—Definitions and Standard Conditions, Available online: https://www.iso.org/fr/standard/69019.html.
7. The pressure-volume diagram of the thorax and lung10.1152/ajplegacy.1946.146.2.161 ↗
8. Spiro, S., Silvestri, G., and Agustí, A. (2012). Clinical Respiratory Medicine, Elsevier. [4th ed.].
9. Shah, R.K., and Sekulic, D.P. (2003). Fundamentals of Heat Exchanger Design, John Wiley & Sons.10.1002/9780470172605 ↗
10. Kakaç, S., Liu, H., and Pramuanjaroenkij, A. (2020). Heat Exchangers: Selection, Rating, and Thermal Design, CRC Press. [4th ed.].10.1201/9780429469862 ↗
11. Electrical resistivity measurements: A review10.1142/S2010194513010970 ↗
12. (2018, September 26). Kanthal®. Available online: https://www.kanthal.com/en/.
13. (2021, February 11). Precision Tubes—Seamless and Welded|Fine Tubes. Available online: www.finetubes.co.uk/.
14. (2021, February 11). Alloy Wire International—Manufacturers of High Performance Exotic Alloys. Available online: https://www.alloywire.com/.
15. ASTM International (2018). ASTM/B258—Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Used as Electrical Conductors, Available online: https://www.astm.org/Standards/B258.htm.
16. The Relationship Between Powder Inhaler Resistance and Peak Inspiratory Conditions in Healthy Volunteers—Implications for In Vitro Testing10.1089/jam.1993.6.99 ↗
17. Dry powder inhalers: The influence of device resistance and powder formulation on drug and lactose deposition in vitro10.1016/S0928-0987(98)00008-6 ↗
18. Characterisation of the Draw Resistance Across a Lit Cigarette