Hyper-spectral Recovery of Cerebral and Extra-Cerebral Tissue Properties Using Continuous Wave Near-Infrared Spectroscopic Data
Source abstract
Abstract
Near-infrared spectroscopy (NIRS) is widely used as a non-invasive method to monitor the hemodynamics of biological tissue. A common approach of NIRS relies on continuous wave (CW) methodology, i.e. utilizing intensity-only measurements, and, in general, assumes homogeneity in the optical properties of the biological tissue. However, in monitoring cerebral hemodynamics within humans, this assumption is not valid due to complex layered structure of the head. The NIRS signal that contains information about cerebral blood hemoglobin levels is also contaminated with extra-cerebral tissue hemodynamics, and any recovery method based on such a priori homogenous approximation would lead to erroneous results. In this work, utilization of hyper-spectral intensity only measurements (i.e., CW) at multiple distances are presented and are shown to recover two-layered tissue properties along with the thickness of top layer, using an analytical solution for a two-layered semi-infinite geometry. It is demonstrated that the recovery of tissue oxygenation index (TOI) of both layers can be achieved with an error of 4.4%, with the recovered tissue thickness of 4% error. When the data is measured on a complex tissue such as the human head, it is shown that the semi-infinite recovery model can lead to uncertain results, whereas, when using an appropriate model accounting for the tissue-boundary structure, the tissue oxygenation levels are recovered with an error of 4.2%, and the extra-cerebral tissue thickness with an error of 11.8%. The algorithm is finally used together with human subject data, demonstrating robustness in application and repeatability in the recovered parameters that adhere well to expected published parameters.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Optical Imaging and Spectroscopy Techniques · Non-Invasive Vital Sign Monitoring · Hemodynamic Monitoring and Therapy
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Computer Science, University of Birmingham, Birmingham B15 2TT, UK
Funding
H2020 Marie Skłodowska-Curie Actions
References (23)
Show source-provided references
1. Postoperative Neuropsychological Dysfunction and Cerebral Oxygenation During Cardiac Surgery10.1055/s-2007-1013224 ↗
2. Cerebral oxygen supply and utilization during infant cardiac surgery10.1002/ana.410370411 ↗
3. A review on continuous wave functional near-infrared spectroscopy and imaging instrumentation and methodology10.1016/j.neuroimage.2013.05.004 ↗
4. Absolute quantification methods in tissue near-infrared spectroscopy
5. Quantitative Reflectance Spectrophotometry For The Noninvasive Measurement Of Photosensitizer Concentration In Tissue During Photodynamic Therapy
6. Tissue oxygenation monitor using NIR spatially resolved spectroscopy
7. Spectrally constrained approach of spatially resolved spectroscopy: towards a better estimate of tissue oxygenation
8. Further improvement in reducing superficial contamination in NIRS using double10.1016/j.neuroimage.2013.01.073 ↗
9. Retinotopic mapping of adult human visual cortex with high-density diffuse optical tomography10.1073/pnas.0611266104 ↗
10. Hallacoglu, B., Sassaroli, A., and Fantini, S. (2013). Optical Characterization of Two-Layered Turbid Media for Non-Invasive, Absolute Oximetry in Cerebral and Extracerebral Tissue. PLoS ONE, 8.10.1371/journal.pone.0064095 ↗
11. Method for recovering quantitative broadband diffuse optical spectra from layered media10.1364/AO.46.004828 ↗
12. Measurement of the optical properties of a two-layer model of the human head using broadband near-infrared spectroscopy10.1364/AO.49.006324 ↗
13. Nonuniqueness in diffusion-based optical tomography10.1364/OL.23.000882 ↗
14. Uniqueness and wavelength optimization in continuous-wave multispectral diffuse optical tomography10.1364/OL.28.002339 ↗
15. Near infrared optical tomography using NIRFAST: Algorithm for numerical model and image reconstruction10.1002/cnm.1162 ↗
16. Noninvasive determination of the optical properties of two-layered turbid media10.1364/AO.37.000779 ↗
17. Spectral and spatial characteristics of the differential pathlengths in non-homogeneous tissues
18. Weight-matrix structured regularization provides optimal generalized least-squares estimate in diffuse optical tomography10.1118/1.2733803 ↗
19. Depth sensitivity and image reconstruction analysis of dense imaging arrays for mapping brain function with diffuse optical tomography10.1364/AO.48.00D137 ↗
20. Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters10.1016/S1053-8119(03)00021-1 ↗
21. Has the time come to use near-infrared spectroscopy as a routine clinical tool in preterm infants undergoing intensive care?10.1098/rsta.2011.0261 ↗
22. Cerebral oximetry10.1093/bjaed/mkw024 ↗
23. Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia10.1007/s10877-016-9942-5 ↗