In spectral domain optical coherence tomography (SD-OCT), any transverse motion component of a detected obliquely moving sample results in a nonlinear relationship between the Doppler phase shift and the axial sample velocity restricting phase-resolved Doppler OCT (PR-DOCT). The size of the deviation from the linear relation depends on the amount of the transverse velocity component, given by the Doppler angle, and the height of the absolute sample velocity. Especially for very small Doppler angles between the horizontal and flow direction, and high flow velocities, the detected Doppler phase shift approaches a limiting value, making an unambiguous measurement of the axial sample velocity by PR-DOCT impossible. To circumvent this limitation, we propose a new method for resonant Doppler flow quantification in spectral domain OCT, where the scanner movement velocity is matched with the transverse velocity component of the sample motion similar to a tracking shot, where the camera is moved with respect to the sample. Consequently, the influence of the transverse velocity component of the tracked moving particles on the Doppler phase shift is negligible and the linear relation between the phase shift and the axial velocity component can be considered for flow velocity calculations. The proposed method is verified using flow phantoms on the basis of 1% Intralipid solution and diluted human blood.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Optical Coherence Tomography Applications · Photoacoustic and Ultrasonic Imaging · Retinal and Macular Surgery
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Medical Physics and Biomedical Engineering, Faculty of Medicine Carl Gustav Carus, Technische Universität Dresden, 01307 Dresden, Germany
Clinical Sensoring and Monitoring, Anesthesiology and Intensive Care Medicine, Faculty of Medicine Carl Gustav Carus, Technische Universität Dresden, 01307 Dresden, Germany
References (30)
Show source-provided references
1. Optical Coherence Tomography10.1126/science.1957169 ↗
2. Performance of Fourier domain vs. time domain optical coherence tomography10.1364/OE.11.000889 ↗
3. Sensitivity advantage of swept source and Fourier domain optical coherence tomography10.1364/OE.11.002183 ↗
4. Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography10.1364/OL.28.002067 ↗
5. Fourier domain mode locking (FDML): A new laser operating regime and applications for optical coherence tomography10.1364/OE.14.003225 ↗
6. Kirsten, L., Domaschke, T., Schneider, C., Walther, J., Meissner, S., Hampel, R., and Koch, E. (2015). Visualization of dynamic boiling processes using high-speed optical coherence tomography. Exp. Fluids, 56.10.1007/s00348-015-1921-y ↗
7. Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography10.1364/OE.9.000780 ↗
8. Polarization sensitive optical coherence tomography in the human eye10.1016/j.preteyeres.2011.06.003 ↗
9. Toward assessments of blood oxygen saturation by spectroscopic optical coherence tomography10.1364/OL.30.001015 ↗
10. Quantitative cerebral blood flow with optical coherence tomography10.1364/OE.18.002477 ↗
11. Doppler optical coherence tomography10.1016/j.preteyeres.2014.03.004 ↗
12. Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity10.1364/OL.25.000114 ↗
13. Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography10.1364/OE.11.003116 ↗
14. Phase-resolved optical frequency domain imaging10.1364/OPEX.13.005483 ↗
15. Scanning protocols dedicated to smart velocity ranging in spectral OCT10.1364/OE.17.023736 ↗
16. Relation of joint spectral and time domain optical coherence tomography (jSTdOCT) and phase-resolved Doppler OCT10.1364/OE.22.023129 ↗
17. Resonant Doppler flow imaging and optical vivisection of retinal blood vessels10.1364/OE.15.000408 ↗
18. Resonant Doppler imaging with common path OCT10.1117/12.831852 ↗
19. Limits of Fourier domain Doppler-OCT at high velocities10.1016/j.sna.2009.01.022 ↗
20. Transverse motion as a source of noise and reduced correlation of the Doppler phase shift in spectral domain OCT10.1364/OE.17.019698 ↗
21. Impact of a detector dead time in phase resolved Doppler analysis using spectral domain optical coherence tomography10.1364/JOSAA.34.000241 ↗
22. Automatic retinal blood flow calculation using spectral domain optical coherence tomography10.1364/OE.15.015193 ↗
23. Simultaneous dual-band optical coherence tomography in the spectral domain for high resolution in vivo imaging10.1364/OE.17.019486 ↗
24. Time-resolved blood flow measurement in the in vivo mouse model by optical frequency domain imaging10.1117/12.831828 ↗
25. Analysis of in vitro and in vivo bidirectional flow velocities by phase-resolved Doppler Fourier-domain OCT10.1016/j.sna.2009.02.025 ↗
26. NADPH oxidase 4 protects against development of endothelial dysfunction and atherosclerosis in LDL receptor deficient mice10.1093/eurheartj/ehv564 ↗
27. Statistical properties of phase-decorrelation in phase-resolved Doppler optical coherence tomography10.1109/TMI.2009.2012891 ↗
28. Shear flow-induced optical inhomogeneity of blood assessed in vivo and in vitro by spectral domain optical coherence tomography in the 1.3 µm wavelength range10.1117/1.3653235 ↗
29. Particle distribution in low-volume capillary-loaded chambers10.1002/j.1939-4640.2005.tb02879.x ↗
30. Influence of shear rate on the optical properties of human blood in the spectral range 250 to 1100 nm10.1117/1.2799154 ↗