Seismic Performance of a New Structural Design Solution for First-Story Isolated RC Buildings with Coupled Beam-Column Connections
Source abstract
Abstract
This study proposes a new structural design of the first-story isolation system in reinforced concrete (RC) structures. Compared to the conditional buildings with independent columns, this new design integrates the independent columns with beams to increase the seismic capacity of the building by increasing the integrated stiffness of the coupled columns and the stability of the isolation system. The seismic responses of the proposed structure and the corresponding isolation effect were investigated by performing a series of numerical simulation and shaking table tests on a typical 7-story RC frame structure. The structure models were subjected to four earthquake waves with two PGAs (peak ground acceleration) of 0.30 g and 0.40 g for seismic analysis regarding the peak acceleration and inter-story displacement. Both simulation and testing results showed that the story acceleration and inter-story displacement of the superstructure in the isolated model decreased significantly. While the substructure below the isolation layer had a negligible decrease of acceleration. The connection of beams with concrete columns significantly increases the seismic capacity of the RC frame buildings compared to non-isolated frame buildings. The coupled beam-column connections could thus be potentially adopted in the practical first-story isolation system to avoid the requirements of large column stiffness and large column size.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Seismic Performance and Analysis · Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Civil Engineering, Fuzhou University, Fuzhou 350116, China
Funding
National Natural Science Foundation of China
References (40)
Show source-provided references
1. Lim, H.K., Kang, J.W., Pak, H., Chi, H.S., Lee, Y.G., and Kim, J. (2018). Seismic response of a three-dimensional asymmetric multi-storey reinforced concrete structure. Appl. Sci., 8.10.3390/app8040479 ↗
2. Wang, B., Wu, T., Dai, H., and Bai, G. (2018). Numerical study on the seismic performance of a steel–concrete hybrid supporting structure in thermal power plants. Appl. Sci., 8.10.3390/app8020294 ↗
3. Seismic duration effect on damping reduction factor using random vibration theory10.1016/j.engstruct.2018.10.074 ↗
4. Reinforced concrete framed structures: Numerical validation of two physical models capable to consider the stiffness contribution of infill panels on framed structures in operative conditions
5. Metal shear panels for seismic protection of buildings: Recent findings and perspectives
6. A general design procedure for failure mechanism control of reinforced concrete frames10.1016/j.engstruct.2016.03.043 ↗
7. Smart and simple design of seismic resistant reinforced concrete frame10.1016/j.compositesb.2016.09.050 ↗
8. Simplified design of elastoplastic structures with metallic yielding dampers based on the concept of uniform damping ratio10.1016/j.engstruct.2018.09.009 ↗
9. Direct design method based on seismic capacity redundancy for structures with metal yielding dampers10.1002/eqe.2977 ↗
10. Mezzi, M. (2006). Enhancing the Seismic Performance of Existing “Pilotis” Configurations, International Association for Bridge and Structural Engineering. IABSE Symposium Report.10.2749/222137806796185643 ↗
11. International Association for Bridge and Structural Engineering (2003). International Building Code 2003, International Code Council.
12. Propagation of earthquake waves in buildings with soft first floor10.1061/(ASCE)0733-9399(1990)116:4(892) ↗
13. Tasaka, M., Moil, N., and Yamamoto, H. (2008, January 24–26). Applying Seismic Isolation to Buildings in Japan-Retrofitting and Middle-Story Isolation. Proceedings of the 18th Analysis and Computation Specialty Conference, Vancouver, BC, Canada.10.1061/41000(315)12 ↗
14. Nonlinear analysis of a reinforced concrete building with a soft first story Collapsed by the 1995 Hyogoken-Nanbu earthquake10.1016/S0958-9465(97)00016-4 ↗
15. Study on application of low-position isolation technology in Frame structure
16. Multiple-slider surfaces bearing for seismic retrofitting of frame structures with soft first stories10.1002/eqe.2198 ↗
17. Retrofit of soft first story structure using seismic isolation technology
18. Industry Standard of the People’s Republic of China (2010). Code for Seismic Design of Building (GB 50011-2010), China Building Industry Press. (In Chinese).
19. Collapse modelling analysis of a precast soft storey building in Australia10.1016/j.engstruct.2010.03.003 ↗
20. Enhancement of the seismic performance of multi-storey buildings by means of dissipative glazing curtain walls10.1016/j.engstruct.2017.09.028 ↗
21. Numerical assessment of vibration control systems for multi-hazard design and mitigation of glass curtain walls10.1016/j.jobe.2017.11.004 ↗
22. Effect of lead rubber bearing characteristics on the response of seismic-isolated bridges10.1007/s12205-008-0187-9 ↗
23. Falborski, T., and Jankowski, R. (2017). Experimental study on effectiveness of a prototype seismic isolation system made of polymeric bearings. Appl. Sci., 7.10.3390/app7080808 ↗
24. Base isolation for seismic retrofitting of structures10.1061/(ASCE)1084-0680(2008)13:4(175) ↗
25. Multi-performance seismic design through an enhanced first-storey isolation system10.1016/j.engstruct.2013.11.002 ↗
26. Experimental investigation of elastomeric isolation bearings with flexible supporting columns10.1061/(ASCE)ST.1943-541X.0001784 ↗
27. P-Δ effects on single-degree-of-freedom structures in earthquakes10.1193/1.1585788 ↗
28. (2018, September 16). Perform 3D, Nonlinear Analysis and Performance Assessment for 3D Structures User Guide. Available online: https://www.ace-hellas.gr/en/software-en-page/cad-solutions-en/csi-products/perform-3d/.
29. Dynamic testing and parameter identification of a base-isolated bridge10.1016/j.engstruct.2013.12.017 ↗
30. Optimum design of TMD system for tall buildings
31. Structural design of double skin facades as damping devices for tall buildings10.1016/j.proeng.2011.07.170 ↗
32. Target-based algorithm for baseline correction of inconsistent vibration signals10.1177/1077546316689014 ↗
33. Baseline correction of vibration acceleration signals with inconsistent initial velocity and displacement10.1177/1687814016675534 ↗
34. Seismic fragility analysis of mid-story isolation and reduction structures based two directions10.4028/www.scientific.net/AMR.739.309 ↗
35. Performance-based seismic design of nonstructural building components: The next frontier of earthquake engineering10.1007/s11803-014-0238-9 ↗
36. Analysis and design of inter-story isolation systems with nonlinear devices10.1080/13632461003668020 ↗
37. Direct displacement design of tall cross laminated timber platform buildings with inter-story isolation10.1016/j.engstruct.2017.09.054 ↗
38. Liu, C., Yang, W., Yan, Z., Lu, Z., and Luo, N. (2017). Base pounding model and response analysis of base-isolated structures under earthquake excitation. Appl. Sci., 7.10.3390/app7121238 ↗
39. Fu, W., Zhang, C., Sun, L., Askari, M., Samali, B., Chung, K.L., and Sharafi, P. (2017). Experimental investigation of a base isolation system incorporating MR dampers with the high-order single step control algorithm. Appl. Sci., 7.10.3390/app7040344 ↗
40. Seismic response of asymmetric steel isolated structures considering vertical component of earthquakes10.1007/s12205-013-0115-5 ↗