Efficient Transmit Delay Calculation in Ultrasound Coherent Plane-Wave Compound Imaging for Curved Array Transducers
Source abstract
Abstract
The recently introduced plane-wave compounding method based on multiple plane-wave excitation has enabled several new applications due to its high frame rate (>1000 Hz). In this paper, a new efficient transmit delay calculation method in plane-wave compound imaging for a curved array transducer is presented. In the proposed method, the transmit delay is only calculated for a steering angle of 0° and is shifted along the element of the transducer to obtain other transmit delays for different steering angles. To evaluate the performance of the proposed method, the computational complexity was measured for various transmission conditions. For the number of elements and plane-wave excitations of 128 and 65, respectively, the number of operations was substantially decreased in the proposed method compared with the conventional method (256 vs. 8320). The benefits of the proposed method were demonstrated with phantom and in vivo experiments, where coherent plane-wave compounding with 65 excitations provided larger CR and CNR values compared to nine excitations (−22.5 dB and 2.7 vs. −11.3 dB and 1.9, respectively). These results indicate the proposed method can effectively reduce the computational complexity for plane-wave compound imaging in curved array transducers.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ultrasound Imaging and Elastography · Ultrasound and Hyperthermia Applications · Ultrasonics and Acoustic Wave Propagation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electronic Engineering, Sogang University, Seoul 04107, Korea
Department of Biomedical Engineering, Sogang University, Seoul 04107, Korea
Funding
National Research Foundation of Korea
References (26)
Show source-provided references
1. Szabo, T. (2004). Diagnostic Ultrasound Imaging: Inside Out, Elsevier Academic Press.
2. Hoskins, P., Martin, K., and Thrush, A. (2010). Diagnostic Ultrasound: Physics and Equipment, Cambridge University Press.10.1017/CBO9780511750885 ↗
3. Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arrays10.1121/1.390734 ↗
4. Multi-transmit beam forming for fast cardiac imaging—Experimental validation and in vivo application10.1109/TMI.2014.2302312 ↗
5. Ultrafast imaging in biomedical ultrasound10.1109/TUFFC.2014.2882 ↗
6. Ultrasonic sector imaging using plane wave synthetic focusing with a convex array transducer10.1121/1.5065391 ↗
7. Bae, S., and Song, T.K. (2018). Methods for grating lobe suppression in ultrasound plane wave imaging. Appl. Sci., 8.10.3390/app8101881 ↗
8. High-frame-rate echocardiography using diverging transmit beams and parallel receive beamforming10.1007/s10396-011-0304-0 ↗
9. Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography10.1109/TUFFC.2009.1067 ↗
10. Ultrafast compound imaging for 2-D motion vector estimation: Application to transient elastography10.1109/TUFFC.2002.1041078 ↗
11. Supersonic shear imaging: A new technique for soft tissue elasticity mapping10.1109/TUFFC.2004.1295425 ↗
12. Shear modulus imaging using 2D transient elastography10.1109/58.996560 ↗
13. Ultrafast compound Doppler imaging: Providing full blood flow characterization10.1109/TUFFC.2011.1780 ↗
14. High PRF ultrafast sliding compound Doppler imaging: Fully qualitative and quantitative analysis of blood flow10.1088/1361-6560/aaa7a2 ↗
15. Spatiotemporal clutter filtering of ultrafast ultrasound data highly increases Doppler and fUltrasound sensitivity10.1109/TMI.2015.2428634 ↗
16. Ultrasound small vessel imaging with block-wise adaptive local clutter filtering10.1109/TMI.2016.2605819 ↗
17. Ultrasound contrast plane wave imaging10.1109/TUFFC.2012.2508 ↗
18. Ultrafast imaging of ultrasound contrast agents10.1016/j.ultrasmedbio.2009.05.020 ↗
19. Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging10.1038/nature16066 ↗
20. Bae, S., Kim, P., Kang, J., and Song, T.K. (2015, January 21–24). An optimized plane wave synthetic focusing imaging for high-resolution convex array imaging. Proceedings of the IEEE International Ultrasonics Symposium (IUS), Taipei, Taiwan.
21. GPU-based beamformer: Fast realization of plane wave compounding and synthetic aperture imaging10.1109/TUFFC.2011.1999 ↗
22. Field: A program for simulating ultrasound systems
23. Noninvasive in vivo liver fibrosis evaluation using supersonic shear imaging: A clinical study on 113 hepatitis c virus patients10.1016/j.ultrasmedbio.2011.05.016 ↗
24. Impact of region of interest (ROI) size on the diagnostic performance of shear wave elastography in differentiating solid breast lesions10.1177/0284185117732097 ↗
25. Performance of shear-wave elastography for breast masses using different region-of-interest (ROI) settings10.1177/0284185117735562 ↗
26. Short-lag spatial coherence of backscattered echoes: Imaging characteristics10.1109/TUFFC.2011.1957 ↗