journal article·2019-05-09Open access

Direct Measurement of Heat Produced during Drilling for Implant Site Preparation

Yongsoo Kim, Sungwon Ju, MinJu Kim, Minsu Park, Sangho Jun, Jinsoo Ahn

Applied Sciences· Volume 9· Issue 9

Abstract

The aim of this study was to directly measure the temperature of the drill during implant site preparation. The measured temperature was compared to that previously reported inside the bone. The temperature change of the drill was measured using a thermocouple inserted inside the stainless steel drill using an 18-gauge needle and mercury-containing slip ring. Three thermocouples were inserted into the bone with different depths of 10 mm, 5 mm and 1 mm. The thermocouple was 0.5 mm away from the periphery of the drilled hole with a diameter of 3.4 mm. The drill rotating speed varied from 500 rpm to 2000 rpm. Each drilling procedure was performed 10 times, and the average was calculated. The temperature of the drill increased rapidly, and the thermocouples in the bone reached a maximum temperature after the drill temperature started to decrease. The maximum inner temperature of the bone was the highest at a depth of 10 mm. The patterns of the temperature change were similar at different rotating speeds. The actual maximum temperature at the drill and bone interface was significantly higher than the temperature measured inside the bone in previous reports.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Dental Research Institute and Department of Dental Biomaterials Science, School of Dentistry, Seoul National University, 101 Daehak-ro, Jongro-gu, Seoul 03080, Korea

Department of Oral and Maxillofacial Surgery, Anam Hospital, Korea University, 73 Inchon-ro, Seongbuk-gu, Seoul 02841, Korea

Funding

Ministry of Oceans and Fisheries

References (32)

Show source-provided references
1. Osteotomy irrigation: Is it necessary?10.1097/ID.0b013e3181dc9852 ↗
2. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: A study of drill durability
3. Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbit10.1016/0022-3913(83)90174-9 ↗
4. Heat generated by dental implant drills during osteotomy-a review: Heat generated by dental implant drills10.1007/s13191-014-0350-6 ↗
5. The effect of heat on bone regeneration: An experimental study in the rabbit using the bone growth chamber10.1016/0278-2391(84)90417-8 ↗
6. Efficacy of a drug composed of herbal extracts on postoperative discomfort after surgical removal of impacted mandibular third molar: A randomized, triple-blind, controlled clinical trial10.1007/s00784-018-2690-9 ↗
7. Histological changes in bone after insertdon of skeletal fixation pins
8. Thermal osteonecrosis and bone drilling parameters revisited10.1007/s00402-007-0427-3 ↗
9. Heat generation during implant drilling: The significance of motor speed10.1053/joms.2002.34992 ↗
10. Heat production by 3 implant drill systems after repeated drilling and sterilization10.1016/j.joms.2005.10.011 ↗
11. Thermal effects of a combined irrigation method during implant site drilling. A standardized in vitro study using a bovine rib model10.1111/clr.12032 ↗
12. An in vitro study of temperature changes in type 4 bone during implant placement: Bone condensing versus bone drilling10.1016/j.tripleo.2010.08.010 ↗
13. Some fundamental aspects of human joint replacement. Analyses of stresses and heat conduction in bone-prosthesis structures
14. The effect of irrigation on osteotomy depth and bur diameter
15. The Evaluation of the Heat Generated by the Implant Osteotomy Preparation Using a Modified Method of the Measuring Temperature10.11607/jomi.3990 ↗
16. Comparison of heat generation during implant drilling using stainless steel and ceramic drills10.1016/j.joms.2010.11.001 ↗
17. Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury
18. The influence of drill length and irrigation system on heat production during osteotomy preparation for dental implants: An ex vivo study10.1111/clr.12827 ↗
19. Effect of internal irrigation on frictional heat generated from bone drilling
20. Effects of irrigation temperature on heat control in vitro at different drilling depths10.1111/j.1600-0501.2008.01643.x ↗
21. Temperature change in pig rib bone during implant site preparation by low-speed drilling10.1590/S1678-77572010000500016 ↗
22. Investigation of variable factors in drilling bone
23. Influence of the drill material and method of cooling on the development of intrabony temperature during preparation of the site of an implant10.1016/j.bjoms.2012.02.003 ↗
24. A comparative study of removal torque of endosseous implants in the fibula, iliac crest and scapula of cadavers: Preliminary report10.1034/j.1600-0501.1997.080406.x ↗
25. Correlation between placement torque and survival of single-tooth implants
26. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites
27. Effect of drilling into bone
28. Cortical bone drilling and thermal osteonecrosis10.1016/j.clinbiomech.2011.10.010 ↗
29. The effects of operator technique and bur design on temperature during osseous preparation for osteosynthesis self-tapping screws10.1016/S1079-2104(99)70108-3 ↗
30. Temperatures measured in human cortical bone when drilling10.2106/00004623-197254020-00008 ↗
31. Effects of repeated drill use on temperature of bone during preparation for osteosynthesis self-tapping screws10.1016/j.bjoms.2004.11.007 ↗
32. Effects of a drill diameter on the temperature rise in a bone during implant site preparation under clinical conditions10.1177/0954411916660737 ↗