journal article·2026-02-23Open access

Mechanical Behavior of Grouted Sleeve Butt and Lap Joints with Anti-Deflection Measures Under Uniaxial Tension and High-Stress Cyclic Loading

Qiong Yu, Zuorui Wen, Ziming Tang, Hua Wei, Fangjun Zheng, Zhi Zhang, Zhenhai Chen, Jiaqiu Sun

Applied Sciences· Volume 16· Issue 4

Abstract

To compare the mechanical performance differences between sleeve grouting lap and butt joints, a total of 41 lap joints, including 27 standard lap joints and 14 anti-deflection lap joints, and 20 butt joints were subjected to tensile and high-stress cyclic tensile-compression tests. The results indicate that both types of joints failed by tensile fracture of the rebars in uniaxial tension, with the load-bearing capacity, total elongation at maximum force, and ductility generally meeting the code requirements. In high-stress cyclic tests, the load-bearing capacity of both types of joints increased, while the initial stiffness and ductility decreased. The residual deformation of the anti-deflection lap joints and butt joints generally met the specification requirements. Anti-deflection measures can reduce the residual deformation of lap joints; however, their constraint stiffness is limited, resulting in slightly greater residual deformation of lap joints compared to butt joints. After the completion of the high-stress cyclic tensile–compression tests, the maximum longitudinal strain near the reinforcement side of the sleeve’s middle cross-section in lap joints and the absolute value of the maximum circumferential compressive strain were both less than those in butt joints, indicating that lap joints have lower tensile performance requirements for the sleeve. Based on experimental results, a lap length of 12.5 d is recommended, with an additional 4–6 d allowance to enhance splice reliability under high-stress cyclic loading.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Engineering Structural Analysis Methods · Masonry and Concrete Structural Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Disaster Mitigation for Structures, Tongji University, Shanghai 200092, China

Shanxi Construction Engineering Group Co., Ltd., Taiyuan 030006, China

Shanxi No. 2 Construction Engineering Group Co., Ltd., Taiyuan 030013, China

Department of Civil Engineering, Tianjin College, University of Science and Technology Beijing, Tianjin 301830, China

Funding

Scientific Research Project of Tianjin Education Commission

References (42)

Show source-provided references
1. Experimental Research on Seismic Performance of Prefabricated Monolithic Wall Connection of Modular Concrete Structure10.1016/j.istruc.2024.107202 ↗
2. Experimental Study on Seismic Performance of New Concrete Modular Structures with Tie-Rod Inter-Module Connections10.1016/j.istruc.2024.107983 ↗
3. Flexural Behavior of Modular Steel Channel–Concrete Composite Floor Systems with Bolted Connections10.1016/j.engstruct.2023.117217 ↗
4. Alfred, A.Y. (1970). Splice Sleeve for Reinforcing Bars. (US3540763A).
5. Renner, O. (1993). Reinforcing Bar Splice and System for Forming Precast Concrete Members and Structures. (US5468524A).
6. Confining Effect of Mortar-Filled Steel Pipe Splice
7. Behaviour of Grouted Pipe Splice under Incremental Tensile Load10.1016/j.conbuildmat.2012.02.001 ↗
8. Structural Performance of Grouted Sleeve Connectors with and without Transverse Reinforcement for Precast Concrete Structure10.1016/j.proeng.2013.02.017 ↗
9. Tensile Capacity of Grouted Splice Sleeves10.1016/j.engstruct.2015.12.023 ↗
10. Non-Proprietary Bar Splice Sleeve for Precast Concrete Construction10.1016/j.engstruct.2014.10.045 ↗
11. Experimental Study on the Tensile Performance of a Large-Diameter UHPC Grouted Sleeve with Thread10.1016/j.engstruct.2023.116707 ↗
12. The Relationship between Interlocking Mechanism and Bond Strength in Elastic and Inelastic Segment of Splice Sleeve10.1016/j.conbuildmat.2014.01.020 ↗
13. Performance of Grouted Splice Sleeve Connector Under Tensile Load10.15282/jmes.7.2014.8.0106 ↗
14. Yin, F., Yin, S., Zhang, L., and Xu, Y. (2024). Comparative Analysis of the Performance and Study of the Effective Anchorage Length of Semi-Grouted and Fully-Grouted Sleeve Connection. Buildings, 14.10.3390/buildings14092977 ↗
15. Tensile Behavior of Half Grouted Sleeve Connections: Experimental Study and Analytical Modeling10.1016/j.conbuildmat.2017.06.154 ↗
16. Seismic Performance and Retrofit of Precast Concrete Grouted Sleeve Connections10.15554/pcij.01012012.97.109 ↗
17. Axial Load Resistance of Grouted Sleeve Connection for Modular Construction10.1016/j.tws.2020.106883 ↗
18. Grouted Sleeve Connection for Precast Concrete Members
19. Mechanical Performance for Defective and Repaired Grouted Sleeve Connections under Uniaxial and Cyclic Loadings10.1016/j.conbuildmat.2019.117233 ↗
20. Influence of Internal Defects of Semi Grouted Sleeve Connections on the Seismic Performance of Precast Monolithic Concrete Columns10.1016/j.jobe.2022.104009 ↗
21. Anchorage Behavior of Grouting Sleeves under Uniaxial and Cyclic Loading—A Comparative Study of the Internal Structure of Sleeves10.1016/j.jobe.2022.104057 ↗
22. Bond Strength Prediction Model of Defective Grout Materials in Half-Grouted Sleeve Connections under Uniaxial and Cyclic Loadings10.1016/j.conbuildmat.2022.128981 ↗
23. Experimental Investigation on the Post-Fire Cyclic Behavior of Grouted Sleeve Connections10.1016/j.conbuildmat.2021.122394 ↗
24. Mechanical Performance and Stress–Strain Relationships for Grouted Splices Under Tensile and Cyclic Loadings10.1007/s40069-016-0156-5 ↗
25. Yu, Q. (2015). A New Confined Lapping Sleeve. (CN Patent 201420656653.0).
26. Experimental study of grouted sleeve lapping connectors varied in two factors under tensile load
27. Mechanical experimental study on sleeve binding slurry anchor lap joints with different lap lengths
28. Experimental Study and In-Depth Tensile Mechanism Analysis of Grouted Sleeve Lapping Conectors10.1590/1679-78256935 ↗
29. Mechanical Test of Sleeve Grouting Lap Connector with Different Lap Lengths Under High Stress Repeated Tension-compression Loading
30. Experimental Study on the Effect of Supplementary Grouting on the Mechanical Properties of Grout-Deficient Sleeve Connections10.1016/j.istruc.2025.108986 ↗
31. (1999). State Administration of Quality and Technical Supervision. Test Method for Strength of Cement Mortar (Standard No. GB/T 17671-1999).
32. (2003). Ministry of Construction of the People’s Republic of China. Standard Test Method for Mechanical Properties of Ordinary Concrete (Standard No. GB50081-2002).
33. (2016). Technical specification for mechanical joint of reinforcement (Standard No. JGJ 107-2016).
34. (2015). Technical Specification for Grout Sleeve Splicing of Rebars (Standard No. JGJ 355-2015).
35. (2019). Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary (Standard No. ACI Committee 318).
36. Dislocation Structures Induced by Cyclic Deformation in Dual-Phase Ferritic-Martensitic Microstructures10.1016/0921-5093(89)90314-6 ↗
37. The Relationship between Cyclic Stress–Strain Curve and Dislocation Structures in Cyclically Deformed IF Steel10.1016/j.msea.2009.03.050 ↗
38. Horizontal Connections for Precast Concrete Shear Wall Panels Under Cyclic Shear Loading10.15554/pcij.05011996.64.80 ↗
39. Mechanical Properties of Half Grouted Sleeve Connections with Insufficient Grouting and Bar Eccentricity Defects10.1016/j.istruc.2025.108852 ↗
40. On the Early-Age Bond-Slip Behavior of an Eccentric Bar Embedded in a Grouted Sleeve10.1016/j.engstruct.2019.04.020 ↗
41. Grout-Filled Pipe Splices for Precast Concrete Construction10.15554/pcij.01011995.82.93 ↗
42. Zhang, Z., Jiang, S., Cai, W., and Zhang, C. (2022). Effects of Grout Compactness on the Tensile Behavior of Grouted Splice Sleeve Connectors. Appl. Sci., 12.10.3390/app12094595 ↗