journal article·2026-01-04Open access

Comparative Evaluation of Digital Accuracy Among Three Intraoral Scanners for Posterior Implant and Tooth Scans

Isil Kecik Buyukhatipoglu, Melek Ozdemir, Fatih Sari

Applied Sciences· Volume 16· Issue 1

Abstract

Aim: This study evaluates the digital accuracy of posterior implant scans and contralateral molar tooth scans obtained with three different intraoral scanners. Materials and Methods: Using a transfer analog, a Frasaco maxillary model was prepared with a Megagen scan body positioned in the left maxillary molar region. An experienced operator (n = 10) performed all scans with an industrial optical reference scanner and intraoral scanners (Medit i700, TRIOS 3, and TRIOS 5). Scan accuracy was assessed using Geomagic Control X software based on 3D trueness and precision accuracy analysis. One-way ANOVA and Tukey’s HSD tests were applied to identify statistically significant differences in trueness and precision (α = 0.05). Results: In the implant region, TRIOS 5 demonstrated significantly different 3D trueness results and was more successful than TRIOS 3. Medit i700 yielded results comparable to those of TRIOS 3 and TRIOS 5 (p = 0.011). TRIOS 5 exhibited less successful 3D trueness results than the other scanners in the molar region (p = 0.001). No 3D precision differences were observed among intraoral scanners in the implant region (p = 0.561). Medit i700 presented the most favorable precision results in the molar region (p = 0.01). Conclusions: TRIOS 5 supports high impression accuracy and passive fit, while Medit i700 offers more reliable accuracy for contralateral molar scans, which can affect the digital occlusal record.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Orthodontics and Dentofacial Orthopedics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Prosthetic Dentistry, Faculty of Dentistry, Gaziantep University, Gaziantep 27310, Turkey

References (39)

Show source-provided references
1. Comparison of accuracy between digital and conventional implant impressions: Two and three dimensional evaluations10.4047/jap.2022.14.4.236 ↗
2. Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision10.1016/S0022-3913(13)60028-1 ↗
3. Digital versus conventional impressions in fixed prosthodontics: A review10.1111/jopr.12527 ↗
4. Mangano, F.G., Hauschild, U., Veronesi, G., Imburgia, M., Mangano, C., and Admakin, O. (2019). Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: A comparative in vitro study. BMC Oral Health, 19.10.1186/s12903-019-0792-7 ↗
5. Mangano, F., Gandolfi, A., Luongo, G., and Logozzo, S. (2017). Intraoral scanners in dentistry: A review of the current literature. BMC Oral Health, 17.10.1186/s12903-017-0442-x ↗
6. Joda, T., Zarone, F., and Ferrari, M. (2017). The complete digital workflow in fixed prosthodontics: A systematic review. BMC Oral Health, 17.10.1186/s12903-017-0415-0 ↗
7. Scan accuracy of wireless intraoral scanners while digitizing a combined scan body-healing abutment system10.1016/j.jdent.2024.105413 ↗
8. In vitro study of the accuracy and efficiency of wireless intraoral scanners at various battery levels10.1016/j.jdent.2023.104686 ↗
9. Influence of ambient light conditions on the accuracy and scanning time of seven intraoral scanners in complete-arch implant scans10.1016/j.jdent.2022.104138 ↗
10. Intraoral scanners in implant prosthodontics. A narrative review10.1016/j.jdent.2024.105152 ↗
11. Classification of Scanning Errors of Digital Scans Recorded by Using Intraoral Scanners10.1111/jerd.13419 ↗
12. Influence of implant scan body design (height, diameter, geometry, material, and retention system) on intraoral scanning accuracy: A systematic review10.1111/jopr.13774 ↗
13. Effects of scan body material, length and top design on digital implant impression accuracy and usability: An in vitro study10.4047/jap.2025.17.3.125 ↗
14. Digital workflow in implant prosthodontics: The critical aspects for reliable accuracy10.1111/jerd.13004 ↗
15. Accuracy of crowns based on digital intraoral scanning compared to conventional impression-a split-mouth randomised clinical study10.1007/s00784-019-02840-0 ↗
16. Trueness and precision of 5 intraoral scanners for scanning edentulous and dentate complete-arch mandibular casts: A comparative in vitro study10.1016/j.prosdent.2018.10.007 ↗
17. Accuracy of complete- and partial-arch impressions of actual intraoral scanning systems in vitro
18. Son, K., and Lee, K.B. (2020). Effect of tooth types on the accuracy of dental 3D scanners: An in vitro study. Materials, 13.10.3390/ma13071744 ↗
19. Influence of operator experience, scanner type, and scan size on 3D scans10.1016/j.prosdent.2019.12.011 ↗
20. Comparison of the accuracy of intraoral scans between complete-arch scan and quadrant scan10.1186/s40510-020-00337-1 ↗
21. Quantitative clinical adjustment analysis of posterior single implant crown in a chairside digital workflow: A randomized controlled trial10.1111/clr.13519 ↗
22. Accuracy and Efficiency of Digitally Fabricated All-Ceramic Crowns from Conventional Impressions and Intraoral Scans: A Single-Blind Clinical Randomized Controlled Trial10.11607/ijp.8143 ↗
23. Scan accuracy and time efficiency of different implant-supported fixed partial denture situations depending on the intraoral scanner and scanned area: An in vitro study10.1016/j.prosdent.2023.01.029 ↗
24. Marques, V.R., Çakmak, G., Yilmaz, H., Abou-Ayash, S., Donmez, M.B., and Yilmaz, B. (2022). Effect of Scanned Area and Operator on the Accuracy of Dentate Arch Scans with a Single Implant. J. Clin. Med., 11.10.3390/jcm11144125 ↗
25. Influence of 3D analysis software on measured deviations of CAD-CAM resin crowns from virtual design file: An in-vitro study10.1016/j.jdent.2021.103933 ↗
26. Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis: An In Vitro Study10.12659/MSM.946624 ↗
27. Effect of supramucosal height of a scan body and implant angulation on the accuracy of intraoral scanning: An in vitro study10.1016/j.prosdent.2023.01.018 ↗
28. Influence of the implant scan body modifications on trueness of digital impressions10.1016/j.jds.2023.04.004 ↗
29. Eldabe, A.K., Adel-Khattab, D., and Botros, K.H. (2025). Trueness of tooth modified scan bodies as a novel technique for edentulous full arch implant supported dental prosthesis: An in vivo prospective comparative study. BMC Oral Health, 25.10.1186/s12903-024-05172-y ↗
30. Accuracy of maxillary full-arch digital impressions of tooth and implant models made by two intraoral scanners10.1002/cre2.857 ↗
31. Mohajerani, R., Djalalinia, S., and Alikhasi, M. (2025). The Effects of Scan Body Geometry on the Precision and the Trueness of Implant Impressions Using Intraoral Scanners: A Systematic Review. Dent. J., 13.10.3390/dj13060252 ↗
32. Accuracy of tooth-implant impressions: Comparison of five different techniques10.1002/cre2.737 ↗
33. The accuracy of different dental impression techniques for implant-supported dental prostheses: A systematic review and meta-analysis10.1111/clr.13273 ↗
34. In Vitro Comparison of the Accuracy of Conventional Impression and Four Intraoral Scanners in Four Different Implant Impression Scenarios
35. Accuracy of Intraoral Scanners: A Systematic Review of Influencing Factors
36. Trueness of digital implant impressions based on implant angulation and scan body materials10.1038/s41598-021-01442-9 ↗
37. Sun, X., Li, L., and Wen, C. (2025). Effects of inter-implant tooth loss and scan body material on digital impression accuracy: An in vitro study. BMC Oral Health, 25.10.1186/s12903-025-06937-9 ↗
38. Lee, B., Nam, N.-E., Shin, S.-H., Lim, J.-H., Shim, J.-S., and Kim, J.-E. (2021). Evaluation of the Trueness of Digital Implant Impressions According to the Implant Scan Body Orientation and Scanning Method. Appl. Sci., 11.10.3390/app11073027 ↗
39. Moura, G.F., Mendonça, G., Rizzante, F.A.P., Soares, P.V., and Meirelles, L.A.D. (2025). Influence of enamel and dentin roughness on intraoral scanner accuracy. J. Prosthet. Dent., 28, Epub ahead of print.10.1016/j.prosdent.2025.10.018 ↗