Objective: This systematic review aimed to analyze if polywave light curing units can polymerize Bulk Fill resin composites better than monowave. Materials and methods: Inclusion criteria were in vitro studies that evaluated the polymerization of Bulk Fill resin composites by monowave and/or polywave light curing units. Selection of studies, data extraction, and risk-of-bias analysis were performed. Data from selected studies were qualitatively analyzed. A systematic search was performed in May 2025 using PubMed/Medline, EBSCO/Medline, Scopus, and ISI Web of Science databases and grey literature in English, and 788 studies were found. Results: A total of 65 studies were included in the qualitative analysis. Seventeen of them were investigating both monowave and polywave light-curing units for the polymerization of Bulk Fill resin composites. The evidence was graded as medium quality due to the medium risk of bias for most studies. Polywave LED LCUs improved the microhardness ratio, or DC, of Bulk Fill resin composite compared to monowave in 3 of the included studies, while 3 studies revealed that monowave LED LCUs demonstrated a favorable microhardness ratio, or DC, compared to polywave, and the rest of the 11 studies presented material-dependent results. Due to the heterogeneity of the studies included, a meta-analysis was not performed. Conclusion: The existing studies, with their limitations, revealed that polywave light curing units do not seem to have an advantage over monowave in the polymerization of Bulk Fill resin composites.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Surgical Sutures and Adhesives

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Operative Dentistry, Dental School, National and Kapodistrian University of Athens, 11527 Athens, Greece

References (100+)

Show source-provided references
1. The role of polymerization in adhesive dentistry10.1016/j.dental.2018.11.012 ↗
2. Academy of Dental Materials guidance-Resin composites: Part II-Technique sensitivity (handling, polymerization, dimensional changes)10.1016/j.dental.2017.08.188 ↗
3. (2019). Dentistry—Polymer-Based Restorative Materials (Standard No. ISO 4049).
4. Effect of irradiance from curing units on the microhardness of composite—A systematic review
5. Polywave LEDs increase the degree of conversion of composite resins, but not adhesive systems: A systematic review and meta-analysis of in vitro studies10.1007/s10103-025-04368-0 ↗
6. Are polywave light-emitting diodes more effective than monowave ones in the photoactivation of resin-based materials containing alternative photoinitiators? A systematic review10.1016/j.jmbbm.2023.105905 ↗
7. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites10.1007/s00784-013-1177-y ↗
8. Bulk-fill resin-based composites: An in vitro assessment of their mechanical performance10.2341/12-395-L ↗
9. Benzoyl germanium derivatives as novel visible light photoinitiators for dental materials10.1016/j.dental.2007.11.004 ↗
10. Sufficiency of curing in high-viscosity bulk-fill resin composites with enhanced opacity10.1007/s00784-018-2482-2 ↗
11. Clinical performance of bulk-fill and conventional resin composite restorations in posterior teeth: A systematic review and meta-analysis10.1007/s00784-018-2429-7 ↗
12. 5-year clinical performance of posterior bulk-filled resin composite restorations: A double-blind randomized controlled trial10.1016/j.dental.2023.10.018 ↗
13. Depth of cure of bulk fill resin composites: A systematic review10.1111/jerd.12394 ↗
14. Efficiency of polymerization of bulk-fill composite resins: A systematic review10.1590/1807-3107bor-2017.vol31.0059 ↗
15. The PRISMA 2020 statement: An updated guideline for reporting systematic reviews10.1136/bmj.n71 ↗
16. PRISMA 2020 explanation and elaboration: Updated guidance and exemplars for reporting systematic reviews10.1136/bmj.n160 ↗
17. Higgins, J.P.T., Thomas, J., Chandler, J., Cumpston, M., Li, T., Page, M.J., and Welch, V.A. (2024). Cochrane Handbook for Systematic Reviews of Interventions Version 6.5 (Updated August 2024), Wiley-Blackwell. Available online: www.training.cochrane.org/handbook.
18. Development and validation of a risk-of-bias tool for assessing in vitro studies conducted in dentistry: The QUIN10.1016/j.prosdent.2022.05.019 ↗
19. Diversity of short-term DC outcomes in bulk-fill RBCs subjected to a 3 s high-irradiance protocol10.1016/j.dental.2024.08.008 ↗
20. Influence of tip diameter and light spectrum of curing units on the properties of bulk-fill resin composites10.1055/s-0041-1735799 ↗
21. Monowave and polywave light-curing of Bulk-Fill resin composites: Degree of conversion and marginal adaptation following thermomechanical aging
22. Stiffness effect of using polywave or monowave LED units for photo-curing different bulk fill composites10.4012/dmj.2017-278 ↗
23. Bulk-fill composites: Effectiveness of cure with poly- and monowave curing lights and modes10.2341/16-304-L ↗
24. Structural and mechanical properties of a giomer-based bulk fill restorative in different curing conditions10.1590/1678-7757-2016-0662 ↗
25. Effect of thickness on light transmission and Vickers hardness of five bulk-fill resin-based composites using polywave and single-peak light-emitting diode curing lights10.2341/17-163-L ↗
26. Effects of curing modes on depth of cure and microtensile bond strength of bulk fill composites to dentin10.1590/1678-7757-2019-0753 ↗
27. Marovic, D., Par, M., Daničić, P., Marošević, A., Bojo, G., Alerić, M., Antić, S., Puljić, K., Badovinac, A., and Shortall, A.C. (2025). The role of rapid curing on the interrelationship between temperature rise, light transmission, and polymerisation kinetics of bulk-fill composites. Int. J. Mol. Sci., 26.10.3390/ijms26062803 ↗
28. The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites10.1007/s00784-019-02807-1 ↗
29. Light-emitting diode beam profile and spectral output influence on the degree of conversion of bulk fill composites10.2341/16-164-L ↗
30. Depth of cure of 10 resin-based composites light-activated using a laser diode, multi-peak, and single-peak light-emitting diode curing lights10.1016/j.jdent.2022.104141 ↗
31. Effect of light curing units on the polymerization of bulk fill resin-based composites10.1016/j.dental.2018.05.002 ↗
32. Effect of different LED light-curing units on degree of conversion and microhardness of bulk-fill composite resin10.5005/jp-journals-10024-2848 ↗
33. Thomaidis, S., Kampouropoulos, D., Antoniadou, M., and Kakaboura, A. (2024). Evaluation of the depth of cure by microhardness of bulk-fill composites with monowave and polywave LED light-curing units. Appl. Sci., 14.10.3390/app142411532 ↗
34. Evaluation of the influence of light-curing units on the degree of conversion in depth of a bulk-fill resin10.4317/jced.57288 ↗
35. Effect of monowave and polywave light curing on the degree of conversion and microhardness of composites with different photoinitiators: An in vitro study10.4103/jcd.jcd_223_22 ↗
36. Evaluation of the polymerization properties of bulk-fill composite resins
37. Arafa, N., Sherief, D.I., Elmalawanya, L.M., and Nassif, M.S. (2025). Performance of RAFT-based and conventional bulk-fill composites cured with conventional and high irradiance photocuring: A comparative study. BMC Oral Health, 25.10.1186/s12903-025-06046-7 ↗
38. In vitro comparison of mechanical properties and degree of cure of bulk fill composites10.1007/s00784-012-0702-8 ↗
39. Effect of high-intensity curing lights on the polymerization of bulk-fill composites10.1016/j.dental.2018.06.005 ↗
40. Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites10.1007/s10266-015-0227-0 ↗
41. A comparative study of bulk-fill composites: Degree of conversion, post-gel shrinkage and cytotoxicity
42. Impact of high irradiance and short exposure times on the polymerization kinetics of sculptable and flowable bulk-fill composites10.1016/j.jdent.2025.105990 ↗
43. Polymerization efficiency and flexural strength of low-stress restorative composites10.1016/j.dental.2014.03.006 ↗
44. Effect of different light-curing modes and curing times on degree of conversion and microhardness of three different bulk-fill composites: An in vitro study10.1007/s00784-025-06510-2 ↗
45. Curing characteristics of flowable and sculptable bulk-fill composites10.1007/s00784-016-1894-0 ↗
46. Ozciftci, G., Boyacioglu, H., and Turkun, L.S. (2025). Degree of conversion and microhardness of different composite resins polymerized with an advanced LED-curing unit. BMC Oral Health, 25.10.1186/s12903-025-06886-3 ↗
47. Viscoelastic properties, creep behavior and degree of conversion of bulk fill composite resins10.1016/j.dental.2015.09.022 ↗
48. Curing depth and degree of conversion of five bulk-fill composite resins compared to a conventional composite10.2174/1874210601913010422 ↗
49. Short curing time bulk fill composite systems: Volumetric shrinkage, degree of conversion and Vickers hardness10.1590/1807-3107bor-2024.vol38.0030 ↗
50. Comparative evaluation of bulk-fill composite resins: Knoop microhardness, diametral tensile strength and degree of conversion10.2147/CCIDE.S376195 ↗
51. Influence of light-curing time and increment thickness on the properties of bulk fill composite resins with distinct application systems10.1155/2024/2123406 ↗
52. Effect of thickness on the degree of conversion, monomer elution, depth of cure and cytotoxicity of bulk-fill composites10.2334/josnusd.22-0374 ↗
53. Comparative evaluation of the depth of cure and degree of conversion of two bulk fill flowable composites
54. Bulk-fill resin composites: Polymerization properties and extended light curing10.1016/j.dental.2014.12.010 ↗
55. Monomer conversion, microhardness, internal marginal adaptation, and shrinkage stress of bulk-fill resin composites10.1016/j.dental.2015.10.001 ↗
56. Evaluation of physico-mechanical properties and filler particles characterization of conventional, bulk-fill, and bioactive resin-based composites10.1016/j.jmbbm.2020.104288 ↗
57. The effect of high-irradiance rapid polymerization on degree of conversion, monomer elution, polymerization shrinkage and porosity of bulk-fill resin composites10.1016/j.dental.2023.03.016 ↗
58. Curing profile of bulk-fill resin-based composites10.1016/j.jdent.2015.01.002 ↗
59. Raman spectroscopic assessment of degree of conversion of bulk-fill resin composites--changes at 24 h post cure10.2341/14-091-L ↗
60. Roughness profile and surface roughness after toothbrushing and degree of conversion of bulk-fill resins10.1590/1807-3107bor-2024.vol38.0128 ↗
61. Depth-dependence of degree of conversion and microhardness for dual-cure and light-cure composites10.2341/19-074-L ↗
62. Marginal adaptation and depth of cure of flowable versus packable Bulk-Fill restorative materials: An In Vitro Study10.3889/oamjms.2022.8353 ↗
63. Network integrity of bulk-fill composites: Thermal stability, post-curing hardness development and acidic softening10.4012/dmj.2024-247 ↗
64. Post-cure depth of cure of bulk fill dental resin-composites10.1016/j.dental.2013.10.011 ↗
65. Alzahrani, B., Alshabib, A., and Awliya, W. (2023). The depth of cure, sorption and solubility of dual-cured bulk-fill restorative materials. Materials, 16.10.3390/ma16206673 ↗
66. The effect of depth of cure on microhardness between bulk-fill and hybrid composite resin material10.1016/j.sdentj.2024.01.012 ↗
67. Hardness investigation of conventional, bulk fill and flowable dental composites
68. Jakupović, S., Pervan, N., Mešić, E., Gavranović-Glamoč, A., Bajsman, A., Muratović, E., Kazazić, L., and Kantardžić-Kovačević, A. (2023). Assessment of microhardness of conventional and bulk-fill resin composites using different light-curing intensity. Polymers, 15.10.3390/polym15102250 ↗
69. Curing behaviour of high-viscosity bulk-fill composites10.1016/j.jdent.2014.05.012 ↗
70. Effect of different curing protocols on the mechanical properties of low-viscosity bulk-fill composites10.1007/s00784-014-1262-x ↗
71. Influence of increment thickness on radiant energy and microhardness of bulk-fill resin composites10.4012/dmj.2017-032 ↗
72. The effect of different insertion techniques on the depth of cure and vickers surface micro-hardness of two bulk-fill resin composite materials
73. Evaluation of polymerization shrinkage, microhardness, and depth of cure of different types of bulk-fill composites10.1111/jerd.13473 ↗
74. Comparative evaluation of the depth of cure and surface roughness of bulk-fill composites: An in vitro study10.17219/dmp/113003 ↗
75. Skrinjaric, T., Gorseta, K., Bagaric, J., Bucevic Sojcic, P., Stojanovic, J., and Marks, L.A.M. (2025). Comparison of microhardness and depth of cure of six Bulk-Fill resin composites. J. Compos. Sci., 9.10.3390/jcs9080418 ↗
76. How light attenuation and filler content affect the microhardness and polymerization shrinkage and translucency of bulk-fill composites?10.1007/s00784-016-1920-2 ↗
77. Bulk-fill direct restorative materials: An in vitro assessment of their physio-mechanical properties10.3390/oral1020008 ↗
78. Effect of a broad-spectrum LED curing light on the Knoop microhardness of four posterior resin based composites at 2, 4 and 6-mm depths10.1016/j.jdent.2015.11.004 ↗
79. Polymerization shrinkage and depth of cure of bulk fill flowable composite resins10.2341/12-484-L ↗
80. Polymerization shrinkage, microhardness and depth of cure of bulk fill resin composites10.4012/dmj.2018-063 ↗
81. Influence of multiple peak light-emitting-diode curing unit beam homogenization tips on microhardness of resin composites10.2341/19-027-L ↗
82. Depth of cure of contemporary bulk-fill resin-based composites10.4012/dmj.2015-402 ↗
83. Jakupović, S., Pervan, N., Duratbegović, D., Jakupović, V., Muratović, E., and Kobašlija, S. (2025). Evaluation of the effect of different light-curing protocols on the microhardness of contemporary Bulk-Fill resin composites. Polymers, 17.10.3390/polym17212889 ↗
84. Characterization of inorganic filler content, mechanical properties, and light transmission of bulk-fill resin composites10.2341/16-024-L ↗
85. Academy of Dental Materials guidance-resin composites: Part I-mechanical properties10.1016/j.dental.2017.04.013 ↗
86. Light intensity effects on resin-composite degree of conversion and shrinkage strain10.1016/S0109-5641(00)00020-8 ↗
87. Wear and marginal breakdown of composites with various degrees of cure10.1177/00220345970760081401 ↗
88. Degree of double bond conversion in light-cured composites10.1016/S0109-5641(87)80055-6 ↗
89. Factors affecting the depth of cure of UV-polymerized composites10.1177/00220345800590050901 ↗
90. A comparison of four modes of evaluating depth of cure of light-activated composites10.1177/00220345870660030401 ↗
91. Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins10.1016/S0109-5641(85)80058-0 ↗
92. Correlation of parameters used to estimate monomer conversion in a light-cured composite10.1177/00220345880670060801 ↗
93. Correlation of bottom-to-top surface microhardness and conversion ratios for a variety of resin composite compositions
94. BisGMA/TEGDMA ratio and filler content effects onshrinkage stress10.1016/j.dental.2011.01.007 ↗
95. Influence of UEDMA BisGMA and TEGDMA on selected mechanical properties of experimentalresin composites10.1016/S0109-5641(98)00009-8 ↗
96. The effect of filler and silane content on conversion of resin-based composite10.1016/S0109-5641(02)00062-3 ↗
97. Effect of chemical structure on degree of conversion in light-cured dimethacrylate-based dental resins10.1016/S0142-9612(01)00308-8 ↗
98. Transmission of violet and blue light through conventional (layered) and bulk cured resin-based composites10.1016/j.jdent.2016.06.007 ↗
99. Ilie, N., and Hogg, C. (2024). Kinetic of light transmission during setting and aging of modern flowable bulk-fill composites. Materials, 17.10.3390/ma17174292 ↗