journal article·2025-11-25Open access

Experimental Investigation on the Cavitation Fundamental Characteristics of a Venturi Tube Under Ambient-Pressure Conditions

Guichun Chen, Deyong Zou, Weidong Zhou, Luopeng Li, Fangxiang Wang

Applied Sciences· Volume 15· Issue 23

Abstract

The sensitivities of the cavitation inception conditions and the cavitation discharge coefficient, together with the path independence and uniqueness of inception, underpin reliable use of cavitating Venturi tube under ambient conditions. With a downstream sweep rate of 1/6 °/s verified in preliminary tests, forward and backward quasi-dynamic cavitation evolution processes were sampled to construct pressure- and flow-rate-control paths for the Venturi tube used in this study. Analysis of the control paths shows that, as the critical inlet pressure approaches infinity, the critical pressure ratio and the cavitation discharge coefficient approach characteristic values of 0.6364 and 0.5573. With ±3% practical equivalence margins, they become insensitive to the critical inlet pressure above thresholds of 2.4496 and 1.7167 MPa, respectively. The inception conditions are unique; hysteresis in the critical pressure ratio emerges for critical inlet pressures of 0.40–0.45 MPa, and path independence no longer holds for critical inlet pressure exceeding 0.45 MPa. The findings indicate that detecting and controlling Venturi cavitation under ambient conditions must account for the sensitivities and path-dependence of cavitation characteristics, and they provide a useful baseline reference.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Cavitation Phenomena in Pumps · Flow Measurement and Analysis · Tribology and Lubrication Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Petroleum Engineering, China University of Petroleum (East China), Qingdao 266580, China

CNPC Bohai Drilling Engineering Company Ltd., Tianjin 610051, China

References (29)

Show source-provided references
1. Miller, R.W. (1983). Flow Measurement Engineering Handbook, Cambridge University Press. [2nd ed.].
2. (2022). Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular Cross-Section Conduits Running Full—Part 4: Venturi Tubes (Standard No. ISO 5167-4:2022).
3. (2006). Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular Cross-Section Conduits Running Full—Part 4: Venturi Tubes (Standard No. GB/T 2026.4-2006).
4. (2004). Measurement of Fluid Flow in Pipes Using Orifice, Nozzle, and Venturi (Standard No. ASME MFC-3M-2004).
5. (2022). Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular Cross-Section Conduits Running Full-Venturi Tubes (Standard No. BS EN ISO 5167-4:2022).
6. (2022). Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular Cross-Section Conduits Running Full—Part 4: Venturi Tubes (Standard No. NF X10-102-4:2022).
7. (2023). Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular Cross-Section Conduits Running Full—Part 4: Venturi Tubes (Standard No. DIN EN ISO 5167-4:2023-08).
8. (2003). Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular Cross-Section Conduits Running Full—Part 4: Venturi Tubes (Standard No. JIS B 7554-4:2003).
9. Franc, J.-P., and Michel, J.-M. (2005). Fundamentals of Cavitation, Springer.10.1007/1-4020-2233-6 ↗
10. Brennen, C.E. (2014). Cavitation and Bubble Dynamics, Cambridge University Press.10.1017/CBO9781107338760 ↗
11. Performance and image analysis of a cavitating process in a small type venturi10.1016/j.expthermflusci.2013.10.010 ↗
12. Application of small size cavitating venturi as flow controller and flow meter10.1016/j.flowmeasinst.2011.05.001 ↗
13. Experimental investigation of the global cavitation dynamic behavior in a venturi tube with special emphasis on the cavity length variation10.1016/j.ijmultiphaseflow.2016.11.004 ↗
14. Numerical study on the steady flow characteristics of cavitation venturi
15. Zhou, J. (2021). Study on the Flow Characteristics and Influencing Factors of Cavitation-Induced Choked Flow in Venturi Tube. [Master’s Thesis, Shanghai Jiao Tong University].
16. The issue of cavitation number value in studies of water treatment by hydrodynamic cavitation10.1016/j.ultsonch.2016.05.020 ↗
17. Experimental and numerical investigation of the cavitation-induced choked flow in a herschel venturi-tube10.1016/j.flowmeasinst.2016.12.006 ↗
18. Heavy oil upgrading via hydrodynamic cavitation in the presence of an appropriate hydrogen donor
19. Study of venturi tube geometry on the hydrodynamic cavitation for the generation of microbubbles10.1016/j.mineng.2018.11.001 ↗
20. Use of hydrodynamic cavitation in (waste)water treatment10.1016/j.ultsonch.2015.10.010 ↗
21. Effect of value body clearance on valve performance and internal flow field distribution
22. (2006). Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular Cross-Section Conduits Running Full—Part 1: General Principles and Requirements (Standard No. GB/T 2624.1-2006).
23. Dynamics of partial cavitation in an axisymmetric converging-diverging nozzle10.1016/j.ijmultiphaseflow.2018.04.019 ↗
24. Void fraction measurements in partial cavitation regimes by x-ray computed tomography10.1016/j.ijmultiphaseflow.2019.103085 ↗
25. (2008). Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement (Standard No. JCGM 100:2008).
26. Study of cavitation phenomenon using different fuels in a transparent nozzle by hydraulic characterization and visualization10.1016/j.expthermflusci.2012.06.013 ↗
27. Effect of cavitation on the accuracy of Herschel-type venturi tubes
28. Brown, G.O. (2002, January 3–7). The history of the Darcy-Weisbach equation for pipe flow resistance. Proceedings of the 2002 ASCE Civil Engineering Conference and Exposition, Washington, DC, USA.10.1061/40650(2003)4 ↗
29. Simple and explicit formulas for the friction factor in turbulent pipe flow10.1115/1.3240948 ↗