A Review of the Alanine Electron Paramagnetic Resonance Dosimetry Method as a Dose Verification Tool for Low-Dose Electron Beam Applications: Implications on Flash Radiotherapy
Source abstract
Abstract
Alanine dosimetry based on Electron Paramagnetic Resonance (EPR) spectroscopy has been a reliable reference and transfer dosimetry method in high-dose applications, valued for its high precision, accuracy and long-term stability. Additional characteristics, such as dose-rate independence up to 1010 Gy/s under electron beam (e-beam) irradiation, electron energy independence and tissue equivalence, position alanine EPR as a promising candidate to address dosimetric challenges arising in e-beam Flash Radiotherapy (RT), where radiation energy is delivered at Ultra-High Dose-Rates (UHDR) ≥ 40 Gy/s. At such dose-rates, reliable real-time monitoring dosimeters such as ionization chambers in conventional RT, suffer from ion recombination, compromising accuracy in dose determination. Several studies are currently focused on developing real-time beam monitoring systems dedicated specifically for e-beam Flash RT. This creates a need for standardized reference dosimetry methods to validate beam parameters determined by these systems under investigation. This review provides an overview of the potential and limitations of the alanine EPR dosimetry method for control, validation and verification of e-beam Flash RT beam parameters at doses less than 10 Gy, where the method has shown low sensitivity and increased uncertainty. It further discusses strategies to optimize alanine EPR measurements to enhance sensitivity and accuracy at these dose levels. Improved measurement procedures will ensure reliable and accurate e-beam Flash RT accelerator commissioning, performance checks, patient safety and treatment efficacy across all therapeutic dose ranges.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Radiotherapy Techniques · Radiation Therapy and Dosimetry · Radiation Detection and Scintillator Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Physics and Astronomy, Botswana International University of Science and Technology, Private Bag 16, Palapye, Botswana
Institute of Nuclear Chemistry and Technology, ul. Dorodna 16, 03-195 Warszawa, Poland
Funding
International Atomic Energy Agency · Botswana International University of Science and Technology
References (97)
Show source-provided references
1. Ashraf, M.R., Rahman, M., Zhang, R., Williams, B.B., Gladstone, D.J., Pogue, B.W., and Bruza, P. (2020). Dosimetry for FLASH radiotherapy: A review of tools and the role of radioluminescence and Cherenkov emission. Front. Phys., 8.10.3389/fphy.2020.00328 ↗
2. An Overview on Radiotherapy: From Its History to Its Current Applications in Dermatology10.3889/oamjms.2017.122 ↗
3. Gazis, N., Bignami, A., Trachanas, E., Moniaki, M., Gazis, E., Bandekas, D., and Vordos, N. (2024). Simulation Dosimetry Studies for FLASH Radiation Therapy (RT) with Ultra-High Dose Rate (UHDR) Electron Beam. Quantum Beam Sci., 8.10.3390/qubs8020013 ↗
4. Clinical translation of FLASH radiotherapy: Why and how?10.1016/j.radonc.2019.04.008 ↗
5. Radiobiology of the FLASH effect10.1002/mp.15184 ↗
6. Chow, J.C., and Ruda, H.E. (2024). Mechanisms of action in FLASH radiotherapy: A comprehensive review of Physicochemical and Biological processes on cancerous and normal cells. Cells, 13.10.3390/cells13100835 ↗
7. Favaudon, V., Caplier, L., Monceau, V., Pouzoulet, F., Sayarath, M., Fouillade, C., Poupon, M.F., Brito, I., Hupé, P., and Bourhis, J. (2014). Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in mice. Sci. Transl. Med., 6.10.1126/scitranslmed.3008973 ↗
8. Lin, B., Huang, D., Gao, F., Yang, Y., Wu, D., Zhang, Y., Feng, G., Dai, T., and Du, X. (2022). Mechanisms of FLASH effect. Front. Oncol., 12.10.3389/fonc.2022.995612 ↗
9. Feasibility of proton FLASH effect tested by zebrafish embryo irradiation10.1016/j.radonc.2019.06.024 ↗
10. Ultra-high dose-rate, pulsed (FLASH) radiotherapy with carbon ions: Generation of early, transient, highly oxygenated conditions in the tumor environment10.1667/RADE-19-00015.1 ↗
11. FLASH radiotherapy: Newsflash or flash in the pan?10.1002/mp.13685 ↗
12. Technical challenges for FLASH proton therapy10.1016/j.ejmp.2020.08.005 ↗
13. Heavy-ion tumor therapy: Physical and Radiobiological benefits10.1103/RevModPhys.82.383 ↗
14. Lenartowicz-Gasik, A., Misiarz, A., Markopolski, V., Walo, M., Gryczka, U., Bułka, S., Pawałowski, B., Kruszyna-Mochalska, M., and Rzadkiewicz, J. (2024). Verification of real-time dosimetry of ultra-high dose rate beams at AQURE FLASH RT on the sample surface. Pol. J. Med. Phys. Eng., 300–304.10.2478/pjmpe-2024-0038 ↗
15. Ultra-high dose rate dosimetry: Challenges and opportunities for FLASH radiation therapy10.1002/mp.15649 ↗
16. Task Group 142 report: Quality assurance of medical accelerators a10.1118/1.3190392 ↗
17. Flash radiotherapy: Innovative cancer treatment10.3390/encyclopedia3030058 ↗
18. Tuta, C.S., Amiot, M.N., Sommier, L., and Ioan, R.M. (2020). Alanine pellets comparison using EPR dosimetry in the frame of quality assurance for a Gamma Knife system in Romania. Radiat. Phys. Chem., 170.10.1016/j.radphyschem.2019.108653 ↗
19. The European Joint Research Project UHD pulse—Metrology for advanced radiotherapy using particle beams with ultra-high pulse dose rates10.1016/j.ejmp.2020.09.020 ↗
20. Optimization of alanine measurements for fast and accurate dosimetry in FLASH radiation therapy
21. (2013). Standard Practice for Use of an Alanine-EPR Dosimetry System (Standard No. ISO/ASTM International Standard 51607-2013 (E)).
22. Radiation Dosimetry Using Alanine and Electron Paramagnetic Resonance (EPR) Spectroscopy: A new Look at an Old Topic10.1007/s00723-016-0855-8 ↗
23. Clinical applications of alanine/electron spin resonance dosimetry10.1007/s00411-013-0509-2 ↗
24. Verification of the pure alanine in PMMA tube dosimeter applicability for dosimetry of radiotherapy photon beams: A feasibility study10.1007/s13246-015-0360-7 ↗
25. Smith, B.R., Khan, A., and Culberson, W.S. (2021). Commissioning a compact, tabletop EPR spectrometer for alanine dosimetry. Radiat. Meas., 146.10.1016/j.radmeas.2021.106629 ↗
26. Medical reference dosimetry using EPR measurements of alanine: Development of an improved method for clinical dose levels10.1080/02841860802279725 ↗
27. IAEA (2024). Absorbed Dose Determination in External Beam Radiotherapy, International Atomic Energy Agency.
28. In vivo alanine/EPR dosimetry in daily clinical practice: A feasibility study10.1016/S0360-3016(03)00196-2 ↗
29. Recommendations for clinical electron beam dosimetry: Supplement to the recommendations of Task Group 2510.1118/1.3125820 ↗
30. Dosimetry principles, dose measurements, and radiation protection
31. Ryczkowski, A., Kruszyna-Mochalska, M., Pawałowski, B., Bielęda, G., Jodda, A., Adrich, P., and Piotrowski, T. (2025). Shielding disc backscatter calculations in intraoperative radiotherapy using a Monte Carlo simulation based on the method of energy spectra reconstruction. Sci. Rep., 15.10.1038/s41598-025-97522-1 ↗
32. Ayala, R., Soza, Á., García, M.J., García, R., Udías, J.M., and Ibáñez, P. (2025). Development and validation of a Monte Carlo model of a mobile accelerator for intraoperative radiation therapy. Med. Phys., 52.10.1002/mp.18040 ↗
33. Treatment of a first patient with FLASH-radiotherapy10.1016/j.radonc.2019.06.019 ↗
34. Irradiation in a flash: Unique sparing of memory in mice after whole brain irradiation with dose rates above 100 Gy/s10.1016/j.radonc.2017.05.003 ↗
35. The advantage of FLASH radiotherapy confirmed in mini-pig and cat-cancer patients10.1158/1078-0432.CCR-17-3375 ↗
36. Biological benefits of ultra-high dose rate FLASH radiotherapy: Sleeping beauty awoken10.1016/j.clon.2019.04.001 ↗
37. Hyperfractionated or accelerated radiotherapy in head and neck cancer: A meta-analysis10.1016/S0140-6736(06)69121-6 ↗
38. Felici, G., Barca, P., Barone, S., Bortoli, E., Borgheresi, R., De Stefano, S., Di Francesco, M., Grasso, L., Linsalata, S., and Marfisi, D. (2020). Transforming an IORT linac into a FLASH research machine: Procedure and dosimetric characterization. Front. Phys., 8.10.3389/fphy.2020.00374 ↗
39. Alhaddad, L., Osipov, A.N., and Leonov, S. (2024). FLASH Radiotherapy: Benefits, Mechanisms, and Obstacles to Its Clinical Application. Int. J. Mol. Sci., 25.10.3390/ijms252312506 ↗
40. Schulte, R., Johnstone, C., Boucher, S., Esarey, E., Geddes, C.G., Kravchenko, M., Kutsaev, S., Loo, B.W., Méot, F., and Mustapha, B. (2023). Transformative technology for FLASH radiation therapy. Appl. Sci., 13.10.3390/app13085021 ↗
41. On the acceptance, commissioning, and quality assurance of electron FLASH units10.1002/mp.17483 ↗
42. Cheng, C., Xu, L., Jing, H., Selvaraj, B., Lin, H., Pennock, M., Chhabra, A.M., Hasan, S., Zhai, H., and Zhang, Y. (2024). The potential and challenges of proton FLASH in head and neck cancer reirradiation. Cancers, 16.10.3390/cancers16193249 ↗
43. A new solution for UHDP and UHDR (Flash) measurements: Theory and conceptual design of ALLS chamber10.1016/j.ejmp.2022.08.010 ↗
44. Romano, F., Milluzzo, G., Di Martino, F., D’Oca, M.C., Felici, G., Galante, F., Gasparini, A., Mariani, G., Marrale, M., and Medina, E. (2023). First characterization of novel silicon carbide detectors with ultra-high dose rate electron beams for FLASH radiotherapy. Appl. Sci., 13.10.3390/app13052986 ↗
45. Siddique, S., Ruda, H.E., and Chow, J.C. (2023). FLASH radiotherapy and the use of radiation dosimeters. Cancers, 15.10.3390/cancers15153883 ↗
46. Dosimetric and preparation procedures for irradiating biological models with pulsed electron beam at ultra-high dose-rate10.1016/j.radonc.2019.05.004 ↗
47. Validation of an ultrahigh dose rate pulsed electron beam monitoring system using a current transformer for FLASH preclinical studies10.1002/mp.15474 ↗
48. Vértes, A., Nagy, S., Klencsár, Z., Lovas, R.G., and Rösch, F. (2011). Dosimetry Methods. Handbook of Nuclear Chemistry, Springer.10.1007/978-1-4419-0720-2 ↗
49. (2013). Standard Practice for Use of Thermoluminescence-Dosimetry System (TLD System) for Radiation Processing (Standard No. 51956-2013 (E)).
50. Yorke, E., Alecu, R., Ding, L., Fontenla, D., Kalend, A., Kaurin, D., Masterson-McGary, M.E., Marinello, G., Matzen, T., and Saini, A. (2005). Diode In Vivo Dosimetry for Patients Receiving External Beam Radiation Therapy, American Association of Physicists in Medicine.10.37206/88 ↗
51. IAEA (2005). Radiation Oncology Physics, International Atomic Energy Agency. Non-Serial Publications.
52. (2013). Standard Practice for Use of Radiochromic Film Dosimetry System (Standard No. ISO/ASTM International Standard 51275-2013 (E)).
53. AAPM TG 191: Clinical use of luminescent dosimeters: TLDs and OSLDs10.1002/mp.13839 ↗
54. Different dosimeters/detectors used in small-field dosimetry: Pros and cons10.4103/jmss.JMSS_3_18 ↗
55. Comprehensive evaluation and new recommendations in the use of Gafchromic EBT3 film10.1002/mp.16593 ↗
56. Electronic dosimetry in radiation therapy10.1016/j.radmeas.2007.01.005 ↗
57. Evaluation of dose rate and photon energy dependence of Gafchromic EBT3 film irradiating with 6 MV and Co-60 photon beams10.4103/jmss.JMSS_45_18 ↗
58. Precise film dosimetry for stereotactic radiosurgery and stereotactic body radiotherapy quality assurance using Gafchromic™ EBT3 films10.1186/s13014-016-0709-4 ↗
59. Some new approaches in the field of solid state/EPR dosimetry
60. Application of alanine dosimetry in dose assessment for ocular melanoma patients undergoing proton radiotherapy–preliminary results10.1515/nuka-2015-0109 ↗
61. Some physico-technical aspects of the new generation of self-calibrated alanine/EPR dosimeter and results from the international intercomparison trial10.1023/A:1006710421488 ↗
62. Alanine radicals: Structure determination by EPR and ENDOR of single crystals X-irradiated at 295 K10.1021/jp972158k ↗
63. Alanine radicals, Part 3: Properties of the components contributing to the EPR spectrum of X-irradiated alanine dosimeters10.1667/0033-7587(2003)159[0023:ARPPOT]2.0.CO;2 ↗
64. Alanine radicals, Part 4: Relative amounts of radical species in alanine dosimeters after exposure to 6–19 MeV electrons and 10 kV–15 MV photons10.1667/0033-7587(2003)159[0149:ARPRAO]2.0.CO;2 ↗
65. Electron Spin Resonance of an Irradiated Single Crystal of Alanine: Second-Order Effects in Free Radical Resonances10.1063/1.1700912 ↗
66. Alanine radicals. 2. The Composite Polycrystalline Alanine EPR Spectrum Studied by ENDOR, Thermal Annealing, and Spectrum Simulations10.1021/jp026023c ↗
67. Makino, Y., Ueno, M., Shoji, Y., Nyui, M., Nakanishi, I., Fukui, K., and Matsumoto, K.i. (2021). Simplifying quantitative measurement of free radical species using an X-band EPR spectrometer. J. Clin. Biochem. Nutr., 70.10.3164/jcbn.21-83 ↗
68. Eaton, G.R., Eaton, S.S., Barr, D.P., and Weber, R.T. (2010). Quantitative Epr, Springer Science & Business Media.10.1007/978-3-211-92948-3 ↗
69. Weber, R.T. (2011). Xenon’s User Guide, Bruker Biospin Corporation.
70. Karakirova, Y. (2023). Application of Amino Acids for High-Dosage Measurements with Electron Paramagnetic Resonance Spectroscopy. Molecules, 28.10.3390/molecules28041745 ↗
71. Yordanov, N.D., Gancheva, V., and Karakirova, Y. (2012). Some recent developments of EPR dosimetry. EPR of Free Radicals in Solids II: Trends in Methods and Applications, Springer.10.1007/978-94-007-4887-3_8 ↗
72. An absorbed-dose/dose-rate dependence for the alanine-EPR dosimetry system and its implications in high-dose ionizing radiation metrology10.6028/jres.113.007 ↗
73. Gu, R., Wang, J., Wang, P., Mao, X., Lin, B., Tan, W., Du, X., Gao, F., and Wang, T. (2024). Alanine/electron spin resonance dosimetry for FLASH radiotherapy. Radiat. Phys. Chem., 225.10.1016/j.radphyschem.2024.112113 ↗
74. Uncertainty and routine use of Aerial l-alanine–Electron spin resonance dosimetry system10.1016/j.radmeas.2016.03.003 ↗
75. STERIS Applied Sterilization Technologies (2025, July 10). Alanine Loose Pellet Dosimeters. Available online: https://edge.sitecorecloud.io/steriscorp14550-sterisast2aa2-production420c-14c4/media/project/steris/steris/pdffiles/2024/alanine-loose-pellet-tech-sheet.pdf.
76. Malinen, E. (2014). EPR dosimetry in clinical applications. Applications of EPR in Radiation Research, Springer.10.1007/978-3-319-09216-4_14 ↗
77. Sharpe, P.H., and Sephton, J.P. (1998, January 2–5). Alanine dosimetry at NPL-the development of a mailed reference dosimetry service at radiotherapy dose levels. Proceedings of the International Symposium on Techniques for High Dose Dosimetry in Industry, Agriculture and Medicine, Vienna, Austria.
78. Podgorsak, E.B. (2003). Review of Radiation Oncology Physics: A Handbook for Teachers and Students, IAE Agency.
79. Use of alanine for dosimetry intercomparisons among Italian radiotherapy centers10.1016/j.apradiso.2004.08.019 ↗
80. PO-1772: Towards auditing FLASH electron beam dosimetry: Clinical film vs. alanine10.1016/S0167-8140(21)01790-4 ↗
81. Romanyukha, A.A. (2022). Neutron and Gamma Multi-Element Alanine Dosimeter Holder. (17/484,531), U.S. Patent Application.
82. Advancements in accuracy of the alanine EPR dosimetry system: Part III: Usefulness of an adjacent reference sample10.1016/S0969-806X(00)00275-9 ↗
83. Magnettech GmbH and Freiberg Instruments GmbH (Manual and Documentation: MiniScope MS 5000 and MS 5000X, EPR Spectrometer with Scientific Grade Performance, 2019). Manual and Documentation: MiniScope MS 5000 and MS 5000X, EPR Spectrometer with Scientific Grade Performance, Version 7.2.
84. Ptushenko, V.V., and Linev, V.N. (2022). A Review of the Dawn of Benchtop EPR Spectrometers—Innovation That Shaped the Future of This Technology. Molecules, 27.10.3390/molecules27185996 ↗
85. Seco, J., Clasie, B., and Partridge, M. (2014). Review on the characteristics of radiation detectors for dosimetry and imaging. Phys. Med. Biol., 59.10.1088/0031-9155/59/20/R303 ↗
86. A methodology for choosing parameters for ESR readout of alanine dosimeters for radiotherapy10.1016/j.radphyschem.2009.05.020 ↗
87. Advancements in accuracy of the alanine dosimetry system. Part 1. The effects of environmental humidity10.1016/S0969-806X(99)00338-2 ↗
88. Höfel, S., Stehle, M., Zwicker, F., Fix, M.K., and Drescher, M. (2021). A practical EPR dosimetry system for routine use in radiotherapy: Uncertainty analysis of lithium formate dosimeters at the therapeutic dose level. Phys. Med. Biol., 66.10.1088/1361-6560/ab9414 ↗
89. Kim, C.E., Park, J.I., Jung, S., Pak, S.i., Jeong, S., An, S., Kim, C., Jeong, J.H., Kim, H., and Lim, Y.K. (2025). Determination of beam quality correction factors for alanine dosimetry in clinical proton beams. Phys. Medica, 134.10.1016/j.ejmp.2025.104992 ↗
90. Gago-Arias, A., González-Castaño, D., Gómez, F., Peteiro, E., Lodeiro, C., and Pardo-Montero, J. (2015). Development of an alanine dosimetry system for radiation dose measurements in the radiotherapy range. J. Instrum., 10.10.1088/1748-0221/10/08/T08004 ↗
91. The first KREDOS-EPR intercomparison exercise using alanine pellet dosimeter in South Korea10.1016/j.net.2020.03.025 ↗
92. Development of a secondary standard for the absorbed dose to water based on the alanine EPR dosimetry system10.1016/j.apradiso.2004.10.009 ↗
93. Gao, Y., Liu, R., Chang, C.W., Charyyev, S., Zhou, J., Bradley, J.D., Liu, T., and Yang, X. (2022). A potential revolution in cancer treatment: A topical review of FLASH radiotherapy. J. Appl. Clin. Med. Phys., 23.10.1002/acm2.13790 ↗
94. Framework for quality assurance of ultrahigh dose rate clinical trials investigating FLASH effects and current technology gaps10.1016/j.ijrobp.2023.04.018 ↗
95. Anton, M., Kapsch, R., Krauss, A., von Voigts-Rhetz, P., Zink, K., and McEwen, M. (2013). Difference in the relative response of the alanine dosimeter to megavoltage x-ray and electron beams. Phys. Med. Biol., 58.10.1088/0031-9155/58/10/3259 ↗
96. Monte Carlo simulations in radiotherapy dosimetry10.1186/s13014-018-1065-3 ↗
97. Uncertainties in alanine dosimetry in the therapeutic dose range10.1016/S0969-8043(01)00271-8 ↗