Three-Dimensional Accuracy of Clear Aligner Attachment Reproduction Using a Standardized In-House Protocol: An In Vitro Study
Source abstract
Abstract
This in vitro study aimed to quantitatively evaluate the accuracy of reproducing attachments for clear aligner therapy (CAT) using a standardized in-house fabrication protocol and to analyze discrepancies across maxillary tooth types. A custom attachment was designed on a symmetrical master model, and 30 experimental models were fabricated by three-dimensional (3D) printing, template construction, and bonding. Following scanning and superimposition, dimensional, angular, and positional deviations were quantified and statistically analyzed (p < 0.05). Results showed minor mean discrepancies but a consistent pattern of under-reproduction, most evident in the mesial and distal wall angles, as well as in the gingival bevel angle and attachment height. A significant trend was observed in the occlusal bevel, demonstrating marked extrusion in the anterior region that decreased posteriorly. Positional errors were minimal mesiodistally but substantial in the lingual and occlusal directions, with magnitudes varying by tooth type. In conclusion, this study identified consistent, predictable inaccuracies in a simulated in-house attachment reproduction protocol. These findings indicate that similar deviations may occur clinically, potentially affecting the predictability of CAT.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Multimedia Communication and Technology · Semiconductor Lasers and Optical Devices
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Orthodontics, School of Dentistry, Kyungpook National University, Daegu 41940, Republic of Korea
Department of Orthodontics, School of Dentistry, Craniofacial Nerve-Bone Research Center, Kyungpook National University, Daegu 41940, Republic of Korea
References (34)
Show source-provided references
1. Miller, K.B., McGorray, S.P., Womack, R., Quintero, J.C., Perelmuter, M., Gibson, J., Dolan, T.A., and Wheeler, T.T. (2007). A Comparison of Treatment Impacts between Invisalign Aligner and Fixed Appliance Therapy during the First Week of Treatment. Am. J. Orthod. Dentofac. Orthop., 131.10.1016/j.ajodo.2006.05.031 ↗
2. Understanding the Effectiveness of Attachments in Clear Aligner Therapy: Navigating Design, Placement, Material Selection and Biomechanics10.2478/aoj-2024-0021 ↗
3. Forces and Moments Generated by Removable Thermoplastic Aligners: Incisor Torque, Premolar Derotation, and Molar Distalization10.1016/j.ajodo.2014.03.015 ↗
4. The Effect of Digital Diagnostic Setups on Orthodontic Treatment Planning10.1016/j.ajodo.2019.09.008 ↗
5. Sereewisai, B., Chintavalakorn, R., Santiwong, P., Nakornnoi, T., Neoh, S.P., and Sipiyaruk, K. (2023). The Accuracy of Virtual Setup in Simulating Treatment Outcomes in Orthodontic Practice: A Systematic Review. BDJ Open, 9.10.1038/s41405-023-00167-3 ↗
6. Nucera, R., Dolci, C., Bellocchio, A.M., Costa, S., Barbera, S., Rustico, L., Farronato, M., Militi, A., and Portelli, M. (2022). Effects of Composite Attachments on Orthodontic Clear Aligners Therapy: A Systematic Review. Materials, 15.10.3390/ma15020533 ↗
7. Efficacy of Clear Aligners in Controlling Orthodontic Tooth Movement: A Systematic Review10.2319/061614-436.1 ↗
8. Kim, W.-H., Hong, K., Lim, D., Lee, J.-H., Jung, Y., and Kim, B. (2020). Optimal Position of Attachment for Removable Thermoplastic Aligner on the Lower Canine Using Finite Element Analysis. Materials, 13.10.3390/ma13153369 ↗
9. Grassia, V., Ronsivalle, V., Isola, G., Nucci, L., Leonardi, R., and Lo Giudice, A. (2023). Accuracy (Trueness and Precision) of 3D Printed Orthodontic Models Finalized to Clear Aligners Production, Testing Crowded and Spaced Dentition. BMC Oral Health, 23.10.1186/s12903-023-03025-8 ↗
10. Bellocchio, A.M., Portelli, M., Ciraolo, L., Ciancio, E., Militi, A., Peditto, M., Barbera, S., and Nucera, R. (2023). Evaluation of the Clinical Variables Affecting Attachment Reproduction Accuracy during Clear Aligner Therapy. Materials, 16.10.3390/ma16206811 ↗
11. D’Antò, V., Muraglie, S., Castellano, B., Candida, E., Sfondrini, M.F., Scribante, A., and Grippaudo, C. (2019). Influence of Dental Composite Viscosity in Attachment Reproduction: An Experimental In Vitro Study. Materials, 12.10.3390/ma12234001 ↗
12. Kircelli, B.H., Kilinc, D.D., Karaman, A., Sadry, S., Gonul, E.Y., and Gögen, H. (2023). Comparison of the Bond Strength of Five Different Composites Used in the Production of Clear Aligner Attachments. J. Stomatol. Oral Maxillofac. Surg., 124.10.1016/j.jormas.2023.101481 ↗
13. (2025, August 22). Bonding Attachment. Available online: https://learn.aligntech.com/learn/courses/23904/bonding-attachment/lessons/77314/bonding-attachment.
14. Best-Fit Algorithm Influences on Virtual Casts’ Alignment Discrepancies10.1111/jopr.13537 ↗
15. Evaluation of Invisalign Treatment Effectiveness and Efficiency Compared with Conventional Fixed Appliances Using the Peer Assessment Rating Index10.1016/j.ajodo.2016.06.041 ↗
16. Biomechanics of Clear Aligners: Hidden Truths & First Principles
17. Bonding Positional Accuracy of Attachments and Marginal Adaptation of In-house Aligners—A Quality Improvement Laboratory Study10.1111/ocr.12843 ↗
18. Demir, G.B., Görgülü, S., Topsakal, K.G., and Duran, G.S. (2025). Innovative Use of the Snowplow Technique in Orthodontics: Evaluation of Its Effect on the Accuracy and Manipulation Time in Clear Aligner Attachment Reproduction. J. Dent., 156.10.1016/j.jdent.2025.105716 ↗
19. Perceived Efficacy of Extrusion of Maxillary Lateral Incisors with Aligners10.1016/j.ajodo.2021.11.016 ↗
20. Effect of Clear Aligner Attachment Design on Extrusion of Maxillary Lateral Incisors: A Multicenter, Single-Blind Randomized Clinical Trial10.1016/j.ajodo.2023.07.011 ↗
21. Influence of Attachment Bonding Protocol on Precision of the Attachment in Aligner Treatments10.1007/s00056-019-00204-7 ↗
22. Evaluation of Composite Materials with Different Viscosities on the Accuracy of In-Office Aligner Attachments10.1016/j.xaor.2024.07.001 ↗
23. Bellocchio, A.M., Ciancio, E., Ciraolo, L., Barbera, S., and Nucera, R. (2024). Three-Dimensional Printed Attachments: Analysis of Reproduction Accuracy Compared to Traditional Attachments. Appl. Sci., 14.10.3390/app14093837 ↗
24. Raluca Fratila, C., Alonso-Ezpeleta, L., Poveda-Saenz, M., Giovannini, G., Lobo-Galindo, A., Flores-Fraile, J., and Zubizarreta-Macho, Á. (2025). Accuracy Evaluation of Indirect Bonding Techniques for Clear Aligner Attachments Using 3D-Printed Models: An In Silico and Physical Model-Based Study. Materials, 18.10.3390/ma18040780 ↗
25. Comparison of Efficacy and Accuracy of Tooth Movements in Optimized and Conventional Attachments of Clear Aligners—A Systematic Review and Meta-Analysis10.1016/j.jobcr.2025.07.019 ↗
26. Micro-Computed Tomography Evaluation of General Trends in Aligner Thickness and Gap Width after Thermoforming Procedures Involving Six Commercial Clear Aligners: An in Vitro Study10.4041/kjod.2021.51.2.135 ↗
27. Variation of the Modulus of Elasticity of Aligner Foil Sheet Materials Due to Thermoforming10.1007/s00056-021-00327-w ↗
28. Wu, Q., Ogasawara, T., Yoshikawa, N., and Zhai, H. (2018). Stress Evolution of Amorphous Thermoplastic Plate during Forming Process. Materials, 11.10.3390/ma11040464 ↗
29. Thermal and Morphological Skin-Core Effects in Processing of Thermoplastic Composites10.1016/0010-4361(90)90419-W ↗
30. Prediction of Wall Thickness Distribution in Simple Thermoforming Moulds10.5545/sv-jme.2013.1486 ↗
31. Park, S.Y., Choi, S.-H., Yu, H.-S., Kim, S.-J., Kim, H., Kim, K.B., and Cha, J.-Y. (2023). Comparison of Translucency, Thickness, and Gap Width of Thermoformed and 3D-Printed Clear Aligners Using Micro-CT and Spectrophotometer. Sci. Rep., 13.10.1038/s41598-023-36851-5 ↗
32. Schneider, L.F.J., Cavalcante, L.M., and Silikas, N. (2010). Shrinkage Stresses Generated during Resin-Composite Applications: A Review. J. Dent. Biomech., 1.10.4061/2010/131630 ↗
33. Effects of Curing Lights on Polymerization Shrinkage of Composite Attachments in Clear Aligner Treatment: A Microcomputed Tomography Study10.1016/j.ajodo.2024.08.012 ↗
34. Comparative Study of Three Composite Materials in Bonding Attachments for Clear Aligners10.1111/ocr.12465 ↗