This study proposes a novel heart rate estimation method that detects subtle cardiac-induced vibrations propagated through the cardiovascular system based on the ballistocardiography (BCG) principle, using a six-axis heart rate sensing device that integrates a three-axis accelerometer and a three-axis gyroscope. To validate the effectiveness of the proposed method, a comparative analysis was conducted against heart rate measurements obtained from photoplethysmography (PPG) sensors, which are widely used in conventional heart rate monitoring. Experiments were conducted on 20 adult participants, and frequency domain analysis was performed using different time windows of 30 s, 20 s, 8 s, and 4 s. The results showed that the 4 s window provided the highest accuracy in heart rate estimation, demonstrating that the proposed method can effectively capture fine cardiac-induced vibrations. This approach offers a significant advantage by utilizing inertial sensors commonly embedded in wearable devices for heart rate monitoring without the need for additional optical sensors. Compared to optical-based systems, the proposed method is more power-efficient and less affected by environmental factors such as ambient lighting conditions. The findings suggest that heart rate estimation using the six-axis heart rate sensing device presents a reliable, continuous, and non-invasive alternative for cardiovascular monitoring.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Non-Invasive Vital Sign Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of General Education Center, Sangmyung University, 31 Sangmyungdae-gil, Dongnam-gu, Cheonan-si 31066, Chungcheongnam-do, Republic of Korea
Department of Information Security Engineering, Sangmyung University, 31 Sangmyungdae-gil, Dongnam-gu, Cheonan-si 31066, Chungcheongnam-do, Republic of Korea
References (23)
Show source-provided references
1. Colombo, F., and Islam, M.M. (2022). An Overview of the Sensors for Heart Rate Monitoring Used in Extramural and Home Settings. Biosensors, 12.
2. Accurate Heartbeat Detection on Ballistocardiogram Accelerometric Traces
3. Ochi, H., Shimamoto, S., Liu, J., and Yamaoka, Y. (2021, January 14–23). Non-contact Blood Pressure Estimation with Pulse Wave employing Microwave Reflection. Proceedings of the 2021 IEEE International Conference on Communications Workshops (ICC Workshops 2021), Virtual, Online.10.1109/ICCWorkshops50388.2021.9473654 ↗
4. BCG Measurement Using Polymer Optical Fiber Sensors
5. A Wearable System for Full-Body Ballistocardiography
6. Ballistocardiogram (BCG) Measurement by a Differential Pressure Sensor10.1109/JSEN.2020.3046724 ↗
7. Kim, H., Park, J., and Lee, S. (2023). Heart Rate Estimation from BCG Using Transformer-Based Deep Learning. Sensors, 23.
8. Lee, D., Kwon, H., Son, D., Eom, H., Park, C., Lim, Y., Seo, C., and Park, K. (2021). Beat-to-Beat Continuous Blood Pressure Estimation Using Bidirectional Long Short-Term Memory Network. Sensors, 21.10.3390/s21010096 ↗
9. Comparison of ballistocardiogram processing methods based on fiber specklegram sensors10.1109/JSEN.2022.3208318 ↗
10. Gjerde, S., Steffensen, T., Vestad, H., and Steinert, M. (2022, January 27–30). Windows to the Sole: Prototyping Soft Sensors for Wearable Ballistocardiography. Proceedings of the 2022 IEEE-EMBS International Conference on Wearable and Implantable Body Sensor Networks (BSN), Ioannina, Greece.10.1109/BSN56160.2022.9928472 ↗
11. Zhao, H., Zhu, G., Liu, F., Liu, X., Yuan, J., and Zhou, X. (2022, January 6–11). Non-Invasive Optical Fiber Sensing Vital Signs Monitoring Based on Envelope Extraction BCG Data Processing. Proceedings of the2022 IEEE 7th Optoelectronics Global Conference (OGC), Shenzhen, China.10.1109/OGC55558.2022.10050922 ↗
12. Ballistocardiography to identify high left atrial pressure in patients with heart failure10.21037/apm-21-1840 ↗
13. Hytonen, R., Tshala, A., Schreier, J., Holopainen, M., Forsman, A., Oksanen, M., Findling, R.D., Nguyen, L.N., Sigg, S., and Jahne-Raden, N. (2020, January 17–19). Analysing Ballistocardiography for Pervasive Healthcare. Proceedings of the 2020 16th International Conference on Mobility, Sensing and Networking (MSN), Tokyo, Japan.10.1109/MSN50589.2020.00029 ↗
14. Yoshioka, M., and Bounyong, S. (2020, January 13–19). Analysis of Pulse Transit Time Derived from Imaging Photoplethysmography and Microwave Sensor-based Ballistocardiography. Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) Workshops, Seattle, WA, USA.10.1109/CVPRW50498.2020.00151 ↗
15. Han, H., Kim, K., and Lee, S. (2024). Transformer Networks for Heartbeat Detection from Ballistocardiograms. arXiv.
16. Non-Invasive Heart Rate Estimation from Ballistocardiograms Using Bidirectional LSTM Regression10.1109/JBHI.2021.3077002 ↗
17. TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise10.1109/TBME.2014.2359372 ↗
18. Accurate Heart Rate Monitoring During Physical Exercises Using PPG10.1109/TBME.2017.2676243 ↗
19. Estimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensor Fusion10.3390/s110201489 ↗
20. Hernandez, J., Li, Y., Rehg, J.M., and Picard, R.W. (2015, January 18–23). Cardiac Stress Recognition from Wearable Motion Sensors. Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems (CHI) 2015, Seoul, Republic of Korea.
21. Remote Heart Rate Estimation via Convolutional Neural Networks with Transformers
22. Biswas, D., and Veluvolu, K.C. (2019). Heart Rate Estimation from Wrist-Worn Inertial Sensors via PPG-Inspired Deep Learning. Sensors, 19.10.1109/JSEN.2019.2914166 ↗
23. (2025, April 19). TP320. Available online: http://www.laxtha-eshop.kr/goods/view?no=6.