In Vitro Accuracy of Two Different Electronic Apex Locators Under Various Conditions
Source abstract
Abstract
Background: The purpose of this study was to analyze the accuracy of two apex locators using seven different canal irrigants. Methods: Forty multi-rooted extracted teeth were included in this study. The actual canal length (ACL) was determined using a #10 file until the tip was visualized (12× magnification) just within the apical foramen (AF). The teeth were placed in a conductive medium of alginate to test the ACL and electronic canal length (ECL) using both apex locators in various conditions. Seven irrigant solutions were used in the root canal: 0.9% saline, FileEZE EDTA 19%, Glyde EDTA 17%, Consepsis V Chlorhexidine 2% CHX, Chlorcid 3%, citric acid 20%, and EDTA 18%. Results: Within a range of ±0.5 mm from the ACL, Raypex showed an accuracy of 87.5% with 0.9% saline solution, 82.5% with Chlorcid 3%, and 75% with Consepsis V CHX 2% solution. The Ipex showed an accuracy of 82.5% with 0.9% saline solution, 80% with Chlorcid 3%, and 70% with Consepsis V CHX 2% solution. The differences among the canal irrigants were significant for both the Raypex (p = 0.021) and Ipex (p < 0.0001) devices. The mean values showed the greatest variations in ECL accuracy with the combination of Raypex and EDTA 18% (p = 0.042) and with the Ipex and Glyde EDTA 17% (p = 0.026). Conclusions: Canal irrigants have an impact on the accuracy of apex locators. The apex locators showed an accuracy of 80% and greater when 0.9% saline and Chlorcid 3% solutions were used.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Endodontics and Root Canal Treatments · Dental Radiography and Imaging · Health and Medical Education
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Private Dental Practice Zagreb, 10000 Zagreb, Croatia
School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
References (46)
Show source-provided references
1. Factors affecting the long-term results of endodontic treatment10.1016/S0099-2399(07)80180-4 ↗
2. The position and topography of the apical canal constriction and apical foramen10.1111/j.1365-2591.1984.tb00404.x ↗
3. Treatment outcome in endodontics—The Toronto Study. Phase II: Initial. treatment10.1097/00004770-200405000-00002 ↗
4. Topographical evaluation of the major apical foramen in permanent human teeth10.1111/j.1365-2591.2008.01513.x ↗
5. Cohen, S., and Burns, R.C. (1994). Cleaning and shaping the root canal length system. Pathways of the Pulp, Mosby. [6th ed.].
6. Study on iontophoresis
7. An in vitro evaluation of the accuracy of Dentaport ZX apex locator in enlarged root canals10.1111/j.1834-7819.2007.tb00488.x ↗
8. An experimental study of the principle of electronic root canal measurement10.1016/S0099-2399(87)80156-5 ↗
9. Accuracy of different generations of apex locators in determining working length; a systematic review and meta-analysis10.1016/j.sdentj.2021.09.020 ↗
10. Electrical impedance measurements of root canal length10.1111/j.1600-9657.1997.tb00025.x ↗
11. An in vitro evaluation of the accuracy of the root ZX in the presence of various irrigants10.1097/00004770-200103000-00018 ↗
12. Modeling AC current conduction through a human tooth10.1002/bem.10189 ↗
13. A comparison between two electronic apex locators: An ex vivo investigation10.1111/j.1365-2591.2006.01229.x ↗
14. In vivo evaluation of ProPex electronic apex locator10.1016/j.joen.2007.04.003 ↗
15. In vivo evaluation of the Raypex 5 by using different irrigants10.1016/j.joen.2012.05.018 ↗
16. In vivo accuracy of three electronic root canal length measurement devices: Dentaport ZX, Raypex 5 and ProPex II10.1111/j.1365-2591.2012.02060.x ↗
17. In vivo evaluation of the iPex and Root ZX electronic apex locators using various irrigants10.1111/iej.12057 ↗
18. Accuracy of a new apex locator: An in vitro study10.1046/j.1365-2591.2002.00468.x ↗
19. The influence of sodium hypochlorite irrigation on the accuracy of the Root ZX electronic apex locator10.1097/00004770-200208000-00008 ↗
20. Accuracies of seven different apex locators under various conditions10.1016/j.tripleo.2008.04.001 ↗
21. Comparative evaluation of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study10.4103/0976-237X.101068 ↗
22. Comparative Evaluation of Accuracy of Two Electronic Apex Locators in the Presence of Contemporary Irrigants: An In vitro Study10.4103/jispcd.JISPCD_50_18 ↗
23. The Influence of Various Irrigants on the Accuracy of 2 Electronic Apex Locators in Locating Simulated Root Perforations10.1016/j.joen.2016.10.031 ↗
24. Effect of Different Electroconductive Root Canal Irrigations on the Accuracy of Different Apex Locators: An In Vitro Comparative Study10.4103/jispcd.jispcd_192_23 ↗
25. Comparative evaluation of working length determined using integrated apex locator and root ZX mini under various irrigating solutions: An in vivo study
26. Cîmpean, S.I., Chisnoiu, R.M., Colceriu Burtea, A.L., Rotaru, R., Bud, M.G., Delean, A.G., and Pop-Ciutrilă, I.S. (2023). In Vitro Evaluation of the Accuracy of Three Electronic Apex Locators Using Different Sodium Hypochlorite Concentrations. Medicina, 59.10.3390/medicina59050918 ↗
27. Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study10.4103/jpbs.JPBS_122_20 ↗
28. An In vitro Evaluation of the Accuracy of Two Electronic Apex Locators to Determine Working Length in the Presence of Various Irrigants10.4314/ejhs.v26i5.7 ↗
29. The accuracy of three different electronic root canal measuring devices: An in vitro evaluation10.2334/josnusd.44.91 ↗
30. Evaluation of precision of length determination with 3 electronic apex locators: Root ZX, Elements Diagnostic Unit and Apex Locator, and RomiAPEX D-3010.1016/j.tripleo.2007.05.016 ↗
31. The ability of two apex locators to locate the apical foramen: An in vitro study10.1016/j.joen.2005.11.011 ↗
32. Influence of preflaring on the accuracy of length determination with four electronic apex locators10.1016/j.joen.2009.05.030 ↗
33. Electronic apex locator10.1016/j.cden.2003.10.005 ↗
34. Influence of instrument size on the accuracy of different apex locators: An in vitro study10.1016/j.joen.2008.02.019 ↗
35. Marek, E., Łagocka, R., Kot, K., Woźniak, K., and Lipski, M. (2019). The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators. BMC Oral Health, 20.10.1186/s12903-019-0994-z ↗
36. Critical diameter of apical foramen and of file size using the Root ZX apex locator: An in vitro study10.1016/j.joen.2011.05.007 ↗
37. Çelebi Keskin, İ.S., and Yalçın, T.Y. (2025). Evaluation of heated sodium hypochlorite’s effect on the accuracy of contemporary electronic apex locators: An in vitro study. BMC Oral Health, 25.10.1186/s12903-025-06003-4 ↗
38. Comparison of Accuracy in Determining the Root Canal Working Length by Using Two Generations of Apex Locators—An In Vitro Study10.3889/oamjms.2019.696 ↗
39. The Effect of Coronal Pre-flaring and Type of Root Canal Irrigation on Working Length Accuracy Using Electronic Apex Locators10.12688/f1000research.133288.3 ↗
40. A comparative assessment of the accuracies of Raypex 5, Raypex 6, iPex and iPex II electronic apex locators: An in vitro study
41. Comparing the accuracy of two electronic apex locators in the determination of working length and the detection of root perforations: An in vitro study
42. Evaluation of the accuracy of different apex locators in determining the working length during root canal retreatment10.34172/joddd.2020.026 ↗
43. Comparative Evaluation of Accuracy of Ipex, Root Zx Mini, and Epex Pro Apex Locators in Teeth with Artificially Created Root Perforations in Presence of Various Intracanal Irrigants
44. The effect of different root canal irrigations on the accuracy of apex locators: A systematic review10.4317/jced.62049 ↗
45. Comparison of accuracy of two electronic apex loca-tors in the presence of various irrigants: An in vitro study10.4103/0972-0707.94585 ↗
46. Evaluation of the accuracy of three electronic apex locators using glass tubules10.1111/j.1365-2591.2006.01056.x ↗